Development and Experimental Evaluation of a Modified Computational Model for Estimating Occupational Whole-Body Radiation Dose in the Conventional Diagnostic Radiography Unit of Federal Medical Center, Jalingo, Taraba State, Nigeria

Personal dosimetry using thermoluminescent dosimeters (TLDs) can be constrained in resource-limited settings by equipment, processing, and logistical requirements, motivating the development of complementary computational approaches for occupational radiation-dose estimation. This study developed and experimentally evaluated a calibrated computational model for estimating personnel whole-body radiation dose in a conventional diagnostic radiography unit. The primary model incorporated tube potential (kVp), tube current–time product (mAs), source-to-personnel distance, occupancy factor, and a facility-specific calibration coefficient. We obtained six-month personnel dose measurements using chest-worn TLD badges from 15 radiography personnel at the Federal Medical Centre, Jalingo, Nigeria, and compared them with Monte Carlo estimates based on 10,000 simulations per participant. The TLD-measured doses ranged from 0.96 to 1.78 mSv, with a mean of 1.479 ± 0.216 mSv, whereas the corresponding Monte Carlo estimates ranged from 2.204 to 2.265 mSv, with a mean of 2.234 ± 0.017 mSv. The mean model–measurement difference was 0.755 mSv, indicating systematic overestimation by the computational model. Bland–Altman analysis gave 95% limits of agreement of 0.311 to 1.199 mSv, with 14 of 15 observations (93.3%) falling within these limits. One-at-a-time sensitivity analysis demonstrated that source-to-personnel distance and tube potential had the strongest analytical influence on model output because of their squared dependence in the dose equation, while mAs and occupancy factor exhibited first-order dependence. The findings indicate that the calibrated model reproduced the general magnitude of personnel whole-body dose but systematically overestimated the measured TLD values. The model may therefore be useful as a complementary screening and dose-estimation approach, but further calibration and independent validation using larger datasets and multiple radiography facilities are required before application to individual dose assessment

Authors

Institutions

Publication Details

Journal
Nigerian Journal of Physics
Published
2026-10-27
DOI
https://doi.org/10.62292/njp.v35(s).2026.765
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Experimental Evaluation of a Modified Computational Model for Estimating Occupational Whole-Body Radiation Dose in the Conventional Diagnostic Radiography Unit of Federal Medical Center, Jalingo, Taraba State, Nigeria

Osita C. Meludu, Abubakar Musa, Pascal Timtere
1 links
Nigerian Journal of Physics
Radiation Dose and Imaging
article

Development and Experimental Evaluation of a Modified Computational Model for Estimating Occupational Whole-Body Radiation Dose in the Conventional Diagnostic Radiography Unit of Federal Medical Center, Jalingo, Taraba State, Nigeria

Osita C. Meludu, Abubakar Musa, Pascal Timtere
article en

Abstract

Personal dosimetry using thermoluminescent dosimeters (TLDs) can be constrained in resource-limited settings by equipment, processing, and logistical requirements, motivating the development of complementary computational approaches for occupational radiation-dose estimation. This study developed and experimentally evaluated a calibrated computational model for estimating personnel whole-body radiation dose in a conventional diagnostic radiography unit. The primary model incorporated tube potential (kVp), tube current–time product (mAs), source-to-personnel distance, occupancy factor, and a facility-specific calibration coefficient. We obtained six-month personnel dose measurements using chest-worn TLD badges from 15 radiography personnel at the Federal Medical Centre, Jalingo, Nigeria, and compared them with Monte Carlo estimates based on 10,000 simulations per participant. The TLD-measured doses ranged from 0.96 to 1.78 mSv, with a mean of 1.479 ± 0.216 mSv, whereas the corresponding Monte Carlo estimates ranged from 2.204 to 2.265 mSv, with a mean of 2.234 ± 0.017 mSv. The mean model–measurement difference was 0.755 mSv, indicating systematic overestimation by the computational model. Bland–Altman analysis gave 95% limits of agreement of 0.311 to 1.199 mSv, with 14 of 15 observations (93.3%) falling within these limits. One-at-a-time sensitivity analysis demonstrated that source-to-personnel distance and tube potential had the strongest analytical influence on model output because of their squared dependence in the dose equation, while mAs and occupancy factor exhibited first-order dependence. The findings indicate that the calibrated model reproduced the general magnitude of personnel whole-body dose but systematically overestimated the measured TLD values. The model may therefore be useful as a complementary screening and dose-estimation approach, but further calibration and independent validation using larger datasets and multiple radiography facilities are required before application to individual dose assessment

Nigerian Journal of PhysicsVol. 35(S)
Taraba State University (NG), Modibbo Adama University of Technology (NG)
Good health and well-being
Openalex Percentile: Top 13%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon