Metallosis Following Bipolar Hemiarthroplasty Due to Polyethylene Wear: A Case Report

Metallosis following bipolar hemiarthroplasty is an uncommon complication that can result from wear of the concealed polyethylene bearing within the bipolar head.We report the case of a 54-year-old man who presented with six months of progressive right hip pain, four years after bipolar hemiarthroplasty for a transcervical fracture of the femoral neck.Laboratory investigations showed no evidence of infection.Radiographs and computed tomography demonstrated eccentric positioning of the femoral head within the bipolar cup, with peri-trochanteric and acetabular osteolysis and a contained supra-acetabular bone defect measuring approximately 2 × 2 cm.During revision surgery, extensive blackish discoloration of the periprosthetic tissues consistent with metallosis was observed.Examination of the retrieved bipolar head demonstrated complete wear-through of the inner polyethylene liner, resulting in direct metal-on-metal articulation between the inner and outer metal components and generation of substantial metallic debris.A two-stage revision was performed.Extended trochanteric osteotomy was required for femoral stem extraction, followed by extensive debridement and placement of an antibiotic cement spacer.After eight weeks, iliac crest bone grafting was performed for the acetabular defect and the patient underwent conversion to cementless total hip arthroplasty.Histopathological examination confirmed metallosis.At follow-up, the patient was pain-free and independently mobile.This case highlights that concealed polyethylene wear within a bipolar head can progress to direct metal-on-metal articulation, metallosis, osteolysis, and prosthetic failure.Eccentric positioning of the femoral head in a painful bipolar hemiarthroplasty should prompt careful evaluation for polyethylene bearing failure, even when inflammatory markers are normal.Early recognition and appropriate staged revision can facilitate management of extensive metallosis and bone loss.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2026-10-27
DOI
https://doi.org/10.7759/cureus.118660
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Metallosis Following Bipolar Hemiarthroplasty Due to Polyethylene Wear: A Case Report

Aditya Krishna Mootha, Umamahesh Neeli, Uma Shankar Bajjangi, Gangadhar Gundu et al.
1 links
Cureus
Orthopaedic implants and arthroplasty
article

Metallosis Following Bipolar Hemiarthroplasty Due to Polyethylene Wear: A Case Report

Aditya Krishna Mootha, Umamahesh Neeli, Uma Shankar Bajjangi, Gangadhar Gundu, Venkat Mallipudi
article en

Abstract

Metallosis following bipolar hemiarthroplasty is an uncommon complication that can result from wear of the concealed polyethylene bearing within the bipolar head.We report the case of a 54-year-old man who presented with six months of progressive right hip pain, four years after bipolar hemiarthroplasty for a transcervical fracture of the femoral neck.Laboratory investigations showed no evidence of infection.Radiographs and computed tomography demonstrated eccentric positioning of the femoral head within the bipolar cup, with peri-trochanteric and acetabular osteolysis and a contained supra-acetabular bone defect measuring approximately 2 × 2 cm.During revision surgery, extensive blackish discoloration of the periprosthetic tissues consistent with metallosis was observed.Examination of the retrieved bipolar head demonstrated complete wear-through of the inner polyethylene liner, resulting in direct metal-on-metal articulation between the inner and outer metal components and generation of substantial metallic debris.A two-stage revision was performed.Extended trochanteric osteotomy was required for femoral stem extraction, followed by extensive debridement and placement of an antibiotic cement spacer.After eight weeks, iliac crest bone grafting was performed for the acetabular defect and the patient underwent conversion to cementless total hip arthroplasty.Histopathological examination confirmed metallosis.At follow-up, the patient was pain-free and independently mobile.This case highlights that concealed polyethylene wear within a bipolar head can progress to direct metal-on-metal articulation, metallosis, osteolysis, and prosthetic failure.Eccentric positioning of the femoral head in a painful bipolar hemiarthroplasty should prompt careful evaluation for polyethylene bearing failure, even when inflammatory markers are normal.Early recognition and appropriate staged revision can facilitate management of extensive metallosis and bone loss.

Cureus
Shri BM Patil Medical College (IN)
Good health and well-being
Openalex Percentile: Top 10%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Metallosis Following Bipolar Hemiarthroplasty Due to Polyethylene Wear: A Case Report — Aditya Krishna Mootha, Umamahesh Neeli, et al. · Cureus (2026) | TGRS Research Map | TGRS