CFD-Based and Experimental Investigation of Indoor Air Quality: Particulate Matter Dispersion and Exposure in Library Buildings

Indoor air quality (IAQ) is a critical determinant of occupant health, comfort, and cognitive performance, particularly in densely occupied indoor environments such as libraries. This study aims to quantify particulate matter (PM) dispersion dynamics and exposure characteristics through an integrated experimental and computational framework. Three-dimensional CFD simulations were conducted using Flow-3D to resolve the transient transport behavior of multiple PM fractions (PM0.3–PM10) under realistic indoor conditions, and the numerical results were compared with in situ measurements obtained from two library buildings. The findings demonstrate that fine particles (PM0.3–PM1.0) remain suspended at occupant breathing height for extended durations, whereas coarse particles (PM5–PM10) predominantly undergo gravitational settling and accumulate near floor regions. Comparison of the numerical predictions with the experimental measurements showed closer correspondence for PM2.5 and PM10 than for the ultrafine particle fractions. However, because quantitative error metrics such as RMSE, MAPE, or R2 were not calculated in the present study, the level of predictive agreement is not expressed quantitatively. Larger discrepancies for ultrafine particles may be associated with their greater sensitivity to turbulent fluctuations and Brownian motion. Furthermore, the results highlight the critical role of airflow distribution, ventilation configuration, and spatial obstructions in governing particle transport and the formation of localized high-concentration zones. These findings underscore that ventilation effectiveness is primarily controlled by airflow patterns rather than airflow rate alone. The study indicates that CFD, when supported by experimental measurements, can provide a useful tool for assessing IAQ and informing ventilation design strategies to mitigate occupant exposure in indoor environments.

Authors

Institutions

Publication Details

Journal
Gases
Published
2026-10-26
DOI
https://doi.org/10.3390/gases6040052
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CFD-Based and Experimental Investigation of Indoor Air Quality: Particulate Matter Dispersion and Exposure in Library Buildings

Leyla Akbulut, Ahmet Çoşgun, Ali Ufuk Dibiç
Gases
Indoor Air Quality and Microbial Exposure
article

CFD-Based and Experimental Investigation of Indoor Air Quality: Particulate Matter Dispersion and Exposure in Library Buildings

Leyla Akbulut, Ahmet Çoşgun, Ali Ufuk Dibiç
article en

Abstract

Indoor air quality (IAQ) is a critical determinant of occupant health, comfort, and cognitive performance, particularly in densely occupied indoor environments such as libraries. This study aims to quantify particulate matter (PM) dispersion dynamics and exposure characteristics through an integrated experimental and computational framework. Three-dimensional CFD simulations were conducted using Flow-3D to resolve the transient transport behavior of multiple PM fractions (PM0.3–PM10) under realistic indoor conditions, and the numerical results were compared with in situ measurements obtained from two library buildings. The findings demonstrate that fine particles (PM0.3–PM1.0) remain suspended at occupant breathing height for extended durations, whereas coarse particles (PM5–PM10) predominantly undergo gravitational settling and accumulate near floor regions. Comparison of the numerical predictions with the experimental measurements showed closer correspondence for PM2.5 and PM10 than for the ultrafine particle fractions. However, because quantitative error metrics such as RMSE, MAPE, or R2 were not calculated in the present study, the level of predictive agreement is not expressed quantitatively. Larger discrepancies for ultrafine particles may be associated with their greater sensitivity to turbulent fluctuations and Brownian motion. Furthermore, the results highlight the critical role of airflow distribution, ventilation configuration, and spatial obstructions in governing particle transport and the formation of localized high-concentration zones. These findings underscore that ventilation effectiveness is primarily controlled by airflow patterns rather than airflow rate alone. The study indicates that CFD, when supported by experimental measurements, can provide a useful tool for assessing IAQ and informing ventilation design strategies to mitigate occupant exposure in indoor environments.

GasesVol. 6(4)
Akdeniz University (TR), Alanya Alaaddin Keykubat Üniversitesi (TR)
Openalex Percentile: Top 17%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon