Block-Segmented Spatial-Spectrum Imaging for Near-Field Millimeter Waves with Microwave-Photonic Broadband Reception

Active millimeter-wave (mm-wave) imaging uses non-ionizing electromagnetic radiation to detect concealed metallic and dielectric objects and is an important technology for personnel security screening. However, practical security-screening scenarios typically involve short standoff distances and small apertures: the limited physical aperture constrains the two-dimensional imaging resolution, while the short antenna-to-target distance introduces non-negligible high-order nonlinear phase errors for scatterers far from the global coordinate origin, leading to image defocusing. This paper presents a block-segmented spatial-spectrum near-field imaging method combined with a Ka-band microwave-photonic broadband reception prototype. Microwave-photonic broadband reception provides broadband spectral resources to expand the two-dimensional spatial-frequency support, thereby improving imaging resolution under limited-aperture conditions. Meanwhile, the full imaging plane is divided into multiple subblocks, each of which establishes its own local coordinate system. Scattering points within each subblock are kept close to the reference origin to suppress high-order nonlinear phase errors, thereby enhancing the accuracy of local linear spatial-frequency mapping. Finally, global near-field imaging is achieved through sub-image stitching. Simulations with point targets and an aircraft-shaped extended target show that, compared with spatial-spectrum imaging based on a single global coordinate origin, the proposed method effectively suppresses nonlinear phase errors and enables large-area near-field imaging. A discrete-component laboratory prototype implements microwave-photonic broadband reception for a time-division 3-transmit/13-receive acquisition configuration operating from 32 to 38 GHz. The method extends the effective linear imaging span from a 0.2 m × 0.2 m locally focused region to a 1 m × 1 m imaging plane, corresponding to a fivefold increase in linear span and a 25-fold increase in area. Based on the antenna arrangement geometry and the 32–38 GHz operating frequency band, the theoretical two-dimensional imaging resolution of the prototype system is estimated to be approximately 3 cm × 4 cm. Experiments using aluminum-foil strip resolution targets demonstrate that the prototype can resolve adjacent strip scattering regions spaced approximately 3.3 cm and 4.7 cm apart in two orthogonal directions, with a corresponding measured imaging resolution of approximately 3.3 cm × 4.7 cm. The prototype is also capable of reconstructing the primary scattering structure of gun-shaped threat simulation targets. These results indicate that combining block-segmented spatial-spectrum imaging with microwave-photonic broadband reception provides a potentially feasible approach for high-resolution, wide-area millimeter-wave security-screening imaging.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-10-27
DOI
https://doi.org/10.3390/s26216796
Primary Topic
Terahertz technology and applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Block-Segmented Spatial-Spectrum Imaging for Near-Field Millimeter Waves with Microwave-Photonic Broadband Reception

Bao-De Lin, Weiwen Zou, Xing Li, Zhiting Li et al.
1 links
Sensors
Terahertz technology and applications
article

Block-Segmented Spatial-Spectrum Imaging for Near-Field Millimeter Waves with Microwave-Photonic Broadband Reception

Bao-De Lin, Weiwen Zou, Xing Li, Zhiting Li, Yang Zhao
article en

Abstract

Active millimeter-wave (mm-wave) imaging uses non-ionizing electromagnetic radiation to detect concealed metallic and dielectric objects and is an important technology for personnel security screening. However, practical security-screening scenarios typically involve short standoff distances and small apertures: the limited physical aperture constrains the two-dimensional imaging resolution, while the short antenna-to-target distance introduces non-negligible high-order nonlinear phase errors for scatterers far from the global coordinate origin, leading to image defocusing. This paper presents a block-segmented spatial-spectrum near-field imaging method combined with a Ka-band microwave-photonic broadband reception prototype. Microwave-photonic broadband reception provides broadband spectral resources to expand the two-dimensional spatial-frequency support, thereby improving imaging resolution under limited-aperture conditions. Meanwhile, the full imaging plane is divided into multiple subblocks, each of which establishes its own local coordinate system. Scattering points within each subblock are kept close to the reference origin to suppress high-order nonlinear phase errors, thereby enhancing the accuracy of local linear spatial-frequency mapping. Finally, global near-field imaging is achieved through sub-image stitching. Simulations with point targets and an aircraft-shaped extended target show that, compared with spatial-spectrum imaging based on a single global coordinate origin, the proposed method effectively suppresses nonlinear phase errors and enables large-area near-field imaging. A discrete-component laboratory prototype implements microwave-photonic broadband reception for a time-division 3-transmit/13-receive acquisition configuration operating from 32 to 38 GHz. The method extends the effective linear imaging span from a 0.2 m × 0.2 m locally focused region to a 1 m × 1 m imaging plane, corresponding to a fivefold increase in linear span and a 25-fold increase in area. Based on the antenna arrangement geometry and the 32–38 GHz operating frequency band, the theoretical two-dimensional imaging resolution of the prototype system is estimated to be approximately 3 cm × 4 cm. Experiments using aluminum-foil strip resolution targets demonstrate that the prototype can resolve adjacent strip scattering regions spaced approximately 3.3 cm and 4.7 cm apart in two orthogonal directions, with a corresponding measured imaging resolution of approximately 3.3 cm × 4.7 cm. The prototype is also capable of reconstructing the primary scattering structure of gun-shaped threat simulation targets. These results indicate that combining block-segmented spatial-spectrum imaging with microwave-photonic broadband reception provides a potentially feasible approach for high-resolution, wide-area millimeter-wave security-screening imaging.

SensorsVol. 26(21)
Shanghai Jiao Tong University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 24%
Terahertz technology and applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon