A Unified Control and Fault Diagnosis Framework for Single-Area Load Frequency Control: Addressing Sensor Bias Fault Insensitivity in Integral Control Approaches

This paper presents a unified control and fault diagnosis (UCFD) framework for single-area load frequency control (LFC) systems subject to load disturbances and sensor bias faults. Although integral-based LFC can eliminate steady-state frequency errors under nominal conditions, persistent sensor biases may be interpreted as genuine frequency deviations, resulting in erroneous control actions. To address this limitation, the proposed framework replaces integral action with a state-feedback and feedforward control structure and employs two dedicated observers: an augmented-state observer for reconstructing the system states and sensor bias as an additional state, and a residual-generation observer for generating a residual associated with load disturbances. By explicitly incorporating the measured load disturbance into the augmented observer, the proposed approach separates physical load variations from sensor-induced measurement errors and enables unbiased state reconstruction. The residual-generation observer, together with an auxiliary first-order compensator, is then used for load-disturbance rejection, while sensor bias accommodation is performed at the state-estimation level. An analytical expression for the compensator gain is derived from the steady-state disturbance-rejection condition, while its time constant is selected to provide appropriate separation between observer and compensation dynamics. The proposed framework is evaluated through four simulation cases involving load disturbances and sensor bias faults with different temporal profiles, including a combined scenario with model-parameter uncertainty and stochastic load demand. The results are compared with an integral state-feedback approach using frequency-regulation and control-effort metrics. Although integral control provides slightly better nominal performance, the proposed framework achieves substantially improved frequency regulation under faulty conditions and maintains zero steady-state frequency deviation in the presence of persistent sensor bias. Moreover, under faulty and uncertain conditions, the proposed framework reduces both the cumulative squared control effort and the peak control demand, demonstrating enhanced resilience to sensor-bias faults without imposing excessive actuator requirements.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-10-27
DOI
https://doi.org/10.3390/electronics15214971
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Unified Control and Fault Diagnosis Framework for Single-Area Load Frequency Control: Addressing Sensor Bias Fault Insensitivity in Integral Control Approaches

Adnan Alamili, Mamadou Baïlo Camara, Ahmed Al Ameri, Ali M. H. Kadhim
3 links
Electronics
Frequency Control in Power Systems
article

A Unified Control and Fault Diagnosis Framework for Single-Area Load Frequency Control: Addressing Sensor Bias Fault Insensitivity in Integral Control Approaches

Adnan Alamili, Mamadou Baïlo Camara, Ahmed Al Ameri, Ali M. H. Kadhim
article en

Abstract

This paper presents a unified control and fault diagnosis (UCFD) framework for single-area load frequency control (LFC) systems subject to load disturbances and sensor bias faults. Although integral-based LFC can eliminate steady-state frequency errors under nominal conditions, persistent sensor biases may be interpreted as genuine frequency deviations, resulting in erroneous control actions. To address this limitation, the proposed framework replaces integral action with a state-feedback and feedforward control structure and employs two dedicated observers: an augmented-state observer for reconstructing the system states and sensor bias as an additional state, and a residual-generation observer for generating a residual associated with load disturbances. By explicitly incorporating the measured load disturbance into the augmented observer, the proposed approach separates physical load variations from sensor-induced measurement errors and enables unbiased state reconstruction. The residual-generation observer, together with an auxiliary first-order compensator, is then used for load-disturbance rejection, while sensor bias accommodation is performed at the state-estimation level. An analytical expression for the compensator gain is derived from the steady-state disturbance-rejection condition, while its time constant is selected to provide appropriate separation between observer and compensation dynamics. The proposed framework is evaluated through four simulation cases involving load disturbances and sensor bias faults with different temporal profiles, including a combined scenario with model-parameter uncertainty and stochastic load demand. The results are compared with an integral state-feedback approach using frequency-regulation and control-effort metrics. Although integral control provides slightly better nominal performance, the proposed framework achieves substantially improved frequency regulation under faulty conditions and maintains zero steady-state frequency deviation in the presence of persistent sensor bias. Moreover, under faulty and uncertain conditions, the proposed framework reduces both the cumulative squared control effort and the peak control demand, demonstrating enhanced resilience to sensor-bias faults without imposing excessive actuator requirements.

ElectronicsVol. 15(21)
Université Le Havre Normandie (FR), Groupe de Recherche en Electrotechnique et Automatique du Havre (FR), University of Kufa (IQ)
Openalex Percentile: Top 24%
Frequency Control in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon