Retrofitting of Plastered Low-Strength Square Concrete Columns: Axial Performance of CFRP Jacketing without Plaster Removal

Abstract Seismic retrofitting of existing reinforced concrete (RC) columns with fiber-reinforced polymer (FRP) jackets typically requires removing plaster to ensure direct bonding. Although widely practiced, plaster removal increases labor, cost, and environmental impact and can damage the weak concrete surfaces common in substandard buildings. Previous experimental studies have mostly examined FRP confinement applied directly to concrete; however, the axial behavior of columns strengthened without plaster removal remains largely unexplored. In particular, the combined effects of plaster thickness, plaster strength, and FRP jacket configuration have not been systematically evaluated for square columns with retained plaster. This study addresses this gap by experimentally investigating the monotonic axial behavior of plastered concrete columns retrofitted with carbon FRP (CFRP) jackets. Twenty unreinforced square columns (275 × 275 × 550 mm), cast with low-strength concrete (approximately 10 MPa), were tested under axial compression. The parameters varied were plaster thickness (12.5, 25.0, and 37.5 mm), plaster compressive strength (approximately 4.5 and 9.0 MPa), and CFRP jacket configuration (one or two layers). Test results show that, within the engineering-relevant axial strain range (≤1.5%), CFRP jacketing over plastered surfaces effectively maintains the axial load-carrying capacity regardless of plaster properties, demonstrating adequate confinement. These findings confirm the feasibility of CFRP retrofitting without plaster removal and provide a practical framework for strengthening RC members constructed with low-strength concrete. A new constitutive model was developed to represent the axial stress–strain response of plastered CFRP-jacketed concrete, explicitly incorporating plaster thickness, plaster strength, and CFRP jacket configuration. The proposed model captures the experimental behavior with high accuracy and offers a reliable tool for the design and assessment of plaster-interlayered CFRP-strengthened columns.

Authors

Institutions

Publication Details

Journal
Journal of Composites for Construction
Published
2026-10-27
DOI
https://doi.org/10.1061/jccof2.cceng-5641
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Retrofitting of Plastered Low-Strength Square Concrete Columns: Axial Performance of CFRP Jacketing without Plaster Removal

Ali Gurkan Genc, Alper İlki̇, Medine Ispir
1 links
Journal of Composites for Construction
Structural Behavior of Reinforced Concrete
article

Retrofitting of Plastered Low-Strength Square Concrete Columns: Axial Performance of CFRP Jacketing without Plaster Removal

Ali Gurkan Genc, Alper İlki̇, Medine Ispir
article en

Abstract

Abstract Seismic retrofitting of existing reinforced concrete (RC) columns with fiber-reinforced polymer (FRP) jackets typically requires removing plaster to ensure direct bonding. Although widely practiced, plaster removal increases labor, cost, and environmental impact and can damage the weak concrete surfaces common in substandard buildings. Previous experimental studies have mostly examined FRP confinement applied directly to concrete; however, the axial behavior of columns strengthened without plaster removal remains largely unexplored. In particular, the combined effects of plaster thickness, plaster strength, and FRP jacket configuration have not been systematically evaluated for square columns with retained plaster. This study addresses this gap by experimentally investigating the monotonic axial behavior of plastered concrete columns retrofitted with carbon FRP (CFRP) jackets. Twenty unreinforced square columns (275 × 275 × 550 mm), cast with low-strength concrete (approximately 10 MPa), were tested under axial compression. The parameters varied were plaster thickness (12.5, 25.0, and 37.5 mm), plaster compressive strength (approximately 4.5 and 9.0 MPa), and CFRP jacket configuration (one or two layers). Test results show that, within the engineering-relevant axial strain range (≤1.5%), CFRP jacketing over plastered surfaces effectively maintains the axial load-carrying capacity regardless of plaster properties, demonstrating adequate confinement. These findings confirm the feasibility of CFRP retrofitting without plaster removal and provide a practical framework for strengthening RC members constructed with low-strength concrete. A new constitutive model was developed to represent the axial stress–strain response of plastered CFRP-jacketed concrete, explicitly incorporating plaster thickness, plaster strength, and CFRP jacket configuration. The proposed model captures the experimental behavior with high accuracy and offers a reliable tool for the design and assessment of plaster-interlayered CFRP-strengthened columns.

Journal of Composites for ConstructionVol. 31(1)
Istanbul Technical University (TR)
Industry, innovation and infrastructure
Openalex Percentile: Top 16%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon