Case Report: Endoscopic balloon dilation assisted by a polyethylene tube as a protective sheath for benign rectal anastomotic stricture

Background Endoscopic balloon dilation (EBD) is a first-line treatment for benign colorectal anastomotic strictures. However, exposed surgical staples may cause balloon rupture and technical failure during dilation. Case presentation A 56-year-old woman developed a severe rectal anastomotic stricture after a laparoscopic Dixon procedure with a diverting loop ileostomy for rectal adenocarcinoma. A standard colonoscope could not initially pass through the stricture, whereas a 6-mm endoscope could traverse it. EBD was performed sequentially, with stepwise dilation to 12 mm during the first session and dilation to 15 mm during the second session. During the third session, an 18-mm balloon ruptured after contacting exposed staples within the stricture ring. The staples were firmly embedded and could not be removed with grasping forceps. A polyethylene (PE) tube was therefore modified as a temporary protective sheath. The tube was placed over the colonoscope, and the excess tube wall was folded longitudinally and secured with a releasable slipknot made from sterile dental floss to minimize the diameter of the assembly. After the assembly crossed the stricture, the slipknot was released, allowing the PE tube to reopen, cover the exposed staples, and form a protective conduit. A new 18-mm balloon was inflated within the sheath, and dilation was completed without further balloon rupture. Follow-up colonoscopies approximately 2 and 5 months later showed continued anastomotic patency. The patient subsequently underwent ileostomy reversal and reported unobstructed defecation at telephone follow-up on October 27, 2026. Conclusion A temporary PE protective sheath may provide a practical rescue option when a dilation balloon ruptures after contact with exposed staples during colorectal EBD and the staples cannot be removed with grasping forceps. Further clinical experience is required to evaluate the safety and reproducibility of this technique.

Authors

Institutions

Publication Details

Journal
Frontiers in Medicine
Published
2026-11-18
DOI
https://doi.org/10.3389/fmed.2026.1978385
Primary Topic
Esophageal and GI Pathology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Case Report: Endoscopic balloon dilation assisted by a polyethylene tube as a protective sheath for benign rectal anastomotic stricture

Yongfeng Yan, Yufan Ma, Ren Weidong, Qin Zhang et al.
1 links
Frontiers in Medicine
Esophageal and GI Pathology
article

Case Report: Endoscopic balloon dilation assisted by a polyethylene tube as a protective sheath for benign rectal anastomotic stricture

Yongfeng Yan, Yufan Ma, Ren Weidong, Qin Zhang, Keluo Ayi
article en

Abstract

Background Endoscopic balloon dilation (EBD) is a first-line treatment for benign colorectal anastomotic strictures. However, exposed surgical staples may cause balloon rupture and technical failure during dilation. Case presentation A 56-year-old woman developed a severe rectal anastomotic stricture after a laparoscopic Dixon procedure with a diverting loop ileostomy for rectal adenocarcinoma. A standard colonoscope could not initially pass through the stricture, whereas a 6-mm endoscope could traverse it. EBD was performed sequentially, with stepwise dilation to 12 mm during the first session and dilation to 15 mm during the second session. During the third session, an 18-mm balloon ruptured after contacting exposed staples within the stricture ring. The staples were firmly embedded and could not be removed with grasping forceps. A polyethylene (PE) tube was therefore modified as a temporary protective sheath. The tube was placed over the colonoscope, and the excess tube wall was folded longitudinally and secured with a releasable slipknot made from sterile dental floss to minimize the diameter of the assembly. After the assembly crossed the stricture, the slipknot was released, allowing the PE tube to reopen, cover the exposed staples, and form a protective conduit. A new 18-mm balloon was inflated within the sheath, and dilation was completed without further balloon rupture. Follow-up colonoscopies approximately 2 and 5 months later showed continued anastomotic patency. The patient subsequently underwent ileostomy reversal and reported unobstructed defecation at telephone follow-up on October 27, 2026. Conclusion A temporary PE protective sheath may provide a practical rescue option when a dilation balloon ruptures after contact with exposed staples during colorectal EBD and the staples cannot be removed with grasping forceps. Further clinical experience is required to evaluate the safety and reproducibility of this technique.

Frontiers in MedicineVol. 13
Southwest Medical University (CN), Affiliated Hospital of Southwest Medical University (CN)
Good health and well-being
Esophageal and GI Pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon