Impact of sodium hypochlorite and sterilization on R-Motion reciprocating file cyclic fatigue resistance

INTRODUCTION. Chemical exposure and sterilization may influence the fatigue behavior of nickel-titanium endodontic instruments. AIM. To evaluate the effects of immersion in 2.5% sodium hypochlorite and autoclave sterilization on dynamic cyclic fatigue resistance of R-Motion files. MATERIALS AND METHODS. Eighty R25 instruments (25/.06) were allocated to four groups ( n = 20): untreated control, autoclave sterilization, immersion in 2.5 mL of 2.5% NaOCl for 3 minutes, and immersion followed by sterilization. Dynamic fatigue was tested in a metallic canal with a 45° curvature and a radius of 6.06 mm. Time to fracture and fragment length were recorded. RESULTS. No significant differences were found for time to fracture ( p = 0.149; effect size = 0.431; power = 0.899) or fragment length ( p = 0.655; effect size = 0.118; power = 0.120). CONCLUSION. Under the tested conditions, NaOCl exposure, sterilization and their combination did not significantly change cyclic fatigue resistance relative to untreated instruments.

Authors

Institutions

Publication Details

Journal
Endodontics Today
Published
2026-10-27
DOI
https://doi.org/10.36377/et-0252
Primary Topic
Endodontics and Root Canal Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of sodium hypochlorite and sterilization on R-Motion reciprocating file cyclic fatigue resistance

Thais Machado de Carvalho Coutinho, Irís Nogueira Bincelli Seckler, Marília Fagury Videira Marceliano‐Alves, Vivian Ronquete et al.
Endodontics Today
Endodontics and Root Canal Treatments
article

Impact of sodium hypochlorite and sterilization on R-Motion reciprocating file cyclic fatigue resistance

Thais Machado de Carvalho Coutinho, Irís Nogueira Bincelli Seckler, Marília Fagury Videira Marceliano‐Alves, Vivian Ronquete, Marcos Roberto dos Santos Frozoni, Ana Grasiela da Silva Limoeiro, Mariane Jordão da Cunha, C.C.R.B. Felix, C. Silva, J. Alves
article en

Abstract

INTRODUCTION. Chemical exposure and sterilization may influence the fatigue behavior of nickel-titanium endodontic instruments. AIM. To evaluate the effects of immersion in 2.5% sodium hypochlorite and autoclave sterilization on dynamic cyclic fatigue resistance of R-Motion files. MATERIALS AND METHODS. Eighty R25 instruments (25/.06) were allocated to four groups ( n = 20): untreated control, autoclave sterilization, immersion in 2.5 mL of 2.5% NaOCl for 3 minutes, and immersion followed by sterilization. Dynamic fatigue was tested in a metallic canal with a 45° curvature and a radius of 6.06 mm. Time to fracture and fragment length were recorded. RESULTS. No significant differences were found for time to fracture ( p = 0.149; effect size = 0.431; power = 0.899) or fragment length ( p = 0.655; effect size = 0.118; power = 0.120). CONCLUSION. Under the tested conditions, NaOCl exposure, sterilization and their combination did not significantly change cyclic fatigue resistance relative to untreated instruments.

Endodontics Today
Universidade de São Paulo (BR), Universidade Iguaçu (BR), Dr. D.Y. Patil Vidyapeeth, Pune (IN), Faculdade São Leopoldo Mandic (BR), Dr D Y Patil Dental College & Hospital (IN), Universidade de Santo Amaro (BR)
Good health and well-being
Openalex Percentile: Top 11%
Endodontics and Root Canal Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon