Multi-Parameter Optimization and Imaging Performance Evaluation of a 16 × 1 Ce:GAGG Linear Scintillator Detector: A Monte Carlo Simulation Study

Ce:GAGG linear scintillator detectors are promising for high-resolution radiation imaging, but signal sharing near pixel boundaries can affect position resolution. A Geant4 model of a 16 × 1 array was used to assess the lateral pixel dimension (PT), reflector thickness (REF), reflector material, metal interlayer and anti-scatter grid (ASG). The Gaussian-equivalent full width at half maximum (FWHM) of the reconstructed-position distribution and the spatial frequency at 50% modulation transfer (MTF50) were evaluated at central and boundary irradiation positions. PT = 1.0 mm, REF = 0.3 mm and MgO gave a favorable balance between central and boundary responses; the metal interlayer had little influence. A W ASG with 0.60 mm bars and a height of 5.0 mm was selected by comparing total and neighboring-channel energy-deposition tallies in a scattering-phantom geometry. Relative to the reference configuration, the phase-integrated adjacent-channel optical-response fraction decreased from 13.66% to 1.53%, the slanted-edge 10–90% width decreased from 2.951 to 1.876 mm, and the imaging MTF50 point estimate increased from 0.163 to 0.256 cycles mm−1. The integrated recorded optical-photon count decreased by 47.2%. In an ASG-free optical comparison, bar-pattern modulation increased from 0.361 to 0.668. The numerical results apply to the specified simulation and scoring conditions.

Authors

Institutions

Publication Details

Journal
Materials
Published
2026-10-27
DOI
https://doi.org/10.3390/ma19214516
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-Parameter Optimization and Imaging Performance Evaluation of a 16 × 1 Ce:GAGG Linear Scintillator Detector: A Monte Carlo Simulation Study

Meng Cao, Zhu Liu, Zhaoran Guan, Jian Huang et al.
2 links
Materials
Radiation Detection and Scintillator Technologies
article

Multi-Parameter Optimization and Imaging Performance Evaluation of a 16 × 1 Ce:GAGG Linear Scintillator Detector: A Monte Carlo Simulation Study

Meng Cao, Zhu Liu, Zhaoran Guan, Jian Huang, Yanggang Jia, Xinya Wang, Linjun Wang, Haofei Huang
article en

Abstract

Ce:GAGG linear scintillator detectors are promising for high-resolution radiation imaging, but signal sharing near pixel boundaries can affect position resolution. A Geant4 model of a 16 × 1 array was used to assess the lateral pixel dimension (PT), reflector thickness (REF), reflector material, metal interlayer and anti-scatter grid (ASG). The Gaussian-equivalent full width at half maximum (FWHM) of the reconstructed-position distribution and the spatial frequency at 50% modulation transfer (MTF50) were evaluated at central and boundary irradiation positions. PT = 1.0 mm, REF = 0.3 mm and MgO gave a favorable balance between central and boundary responses; the metal interlayer had little influence. A W ASG with 0.60 mm bars and a height of 5.0 mm was selected by comparing total and neighboring-channel energy-deposition tallies in a scattering-phantom geometry. Relative to the reference configuration, the phase-integrated adjacent-channel optical-response fraction decreased from 13.66% to 1.53%, the slanted-edge 10–90% width decreased from 2.951 to 1.876 mm, and the imaging MTF50 point estimate increased from 0.163 to 0.256 cycles mm−1. The integrated recorded optical-photon count decreased by 47.2%. In an ASG-free optical comparison, bar-pattern modulation increased from 0.361 to 0.668. The numerical results apply to the specified simulation and scoring conditions.

MaterialsVol. 19(21)
Shanghai University (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 14%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon