Ti-Containing Mesh Implants Modified by Heterostructures Based on Noble Metal: Fabrication and Study of Biological Activity

Ti-based mesh implants (“titanium silk” TiS and NiTi alloy) offer excellent tissue integration for oncologic surgery but lack intrinsic antibacterial activity. To address this, we fabricated Ag nanoparticles and Ag/M (M = Pt, Au) heterostructures on mesh surfaces via vapor-phase deposition, with noble metal sublayers functionalized by Ag nanofilms and nanoclusters. The modified implants were comprehensively characterized using SEM, AFM, XPS, and ICP-AES and evaluated through in vitro biocompatibility and antibacterial assays. The functional performance of the heterostructures is governed by two key phenomena: a chemical sublayer effect and a geometry-dependent substrate effect, which together dictate ion release kinetics. The Ag/Au interface sustains Ag+ release, whereas Ag/Pt drives rapid Ag+ dissolution. All heterostructures demonstrated effective antibacterial activity against planktonic S. aureus within 24 h. Key factors responsible for reduction in the more resilient P. aeruginosa on the Ag/M heterostructures were hypothesized. Cytotoxicity was dictated by the released ion cocktail: Ag/Pt/NiTi exhibited elevated toxicity which may be associated with the combined release of Ag+, Ni2+ and Pt2+, whereas all Ag/Au-based heterostructures showed excellent biocompatibility (viability 75–108%). Notably, gold sublayers were associated with elevated IL-10 secretion by 72 h. Based on overall biological performance, Ag/Au heterostructures offering sustained antibacterial activity against planktonic bacteria, low cytotoxicity, and a cytokine profile that may be favorable for long-term integration are promising candidates for mesh implants. Also, h-Ag/Pt/TiS showed an optimal balance between rapid antibacterial action and biocompatibility and therefore appears to be a suitable candidate for further in vivo investigation.

Authors

Institutions

Publication Details

Journal
Journal of Functional Biomaterials
Published
2026-10-27
DOI
https://doi.org/10.3390/jfb17110547
Primary Topic
Nanoparticles: synthesis and applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ti-Containing Mesh Implants Modified by Heterostructures Based on Noble Metal: Fabrication and Study of Biological Activity

David Sergeevichev, Anastasiya D. Fedorenko, S. I. Dorovskikh, Aleksey Kolodin et al.
2 links
Journal of Functional Biomaterials
Nanoparticles: synthesis and applications
article

Ti-Containing Mesh Implants Modified by Heterostructures Based on Noble Metal: Fabrication and Study of Biological Activity

David Sergeevichev, Anastasiya D. Fedorenko, S. I. Dorovskikh, Aleksey Kolodin, Tatiana Ya. Guselnikova, Alexander A. Zheravin, Natalya Morozova, Evgeniia Vikulova
article en

Abstract

Ti-based mesh implants (“titanium silk” TiS and NiTi alloy) offer excellent tissue integration for oncologic surgery but lack intrinsic antibacterial activity. To address this, we fabricated Ag nanoparticles and Ag/M (M = Pt, Au) heterostructures on mesh surfaces via vapor-phase deposition, with noble metal sublayers functionalized by Ag nanofilms and nanoclusters. The modified implants were comprehensively characterized using SEM, AFM, XPS, and ICP-AES and evaluated through in vitro biocompatibility and antibacterial assays. The functional performance of the heterostructures is governed by two key phenomena: a chemical sublayer effect and a geometry-dependent substrate effect, which together dictate ion release kinetics. The Ag/Au interface sustains Ag+ release, whereas Ag/Pt drives rapid Ag+ dissolution. All heterostructures demonstrated effective antibacterial activity against planktonic S. aureus within 24 h. Key factors responsible for reduction in the more resilient P. aeruginosa on the Ag/M heterostructures were hypothesized. Cytotoxicity was dictated by the released ion cocktail: Ag/Pt/NiTi exhibited elevated toxicity which may be associated with the combined release of Ag+, Ni2+ and Pt2+, whereas all Ag/Au-based heterostructures showed excellent biocompatibility (viability 75–108%). Notably, gold sublayers were associated with elevated IL-10 secretion by 72 h. Based on overall biological performance, Ag/Au heterostructures offering sustained antibacterial activity against planktonic bacteria, low cytotoxicity, and a cytokine profile that may be favorable for long-term integration are promising candidates for mesh implants. Also, h-Ag/Pt/TiS showed an optimal balance between rapid antibacterial action and biocompatibility and therefore appears to be a suitable candidate for further in vivo investigation.

Journal of Functional BiomaterialsVol. 17(11)
Russian Academy of Sciences (RU), Siberian Branch of the Russian Academy of Sciences (RU), Nikolaev Institute of Inorganic Chemistry (RU), Meshalkin National Medical Research Center (RU)
Russian Science Foundation
Good health and well-being
Openalex Percentile: Top 29%
Nanoparticles: synthesis and applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon