Thermal Performance and Cooling-Energy Savings of Green Roofs in a Hot-Desert Climate: A Verified Coupled Envelope–HVAC Model for Mexicali, Mexico

The cooling benefit of green roofs in the extreme heat of northern Mexico has rarely been quantified with dynamic models that couple the envelope with a controlled air-conditioning system. This study develops such a model for a 4 m × 4 m × 3 m concrete mini-building in Mexicali, Mexico (hot-desert climate), and compares a bare 0.15 m concrete roof with the same slab covered by a green roof. The model couples one-dimensional conduction through the roof and four walls, orientation-specific solar irradiance, evapotranspiration and photosynthesis sinks, a dynamic indoor-air balance and an inverter air conditioner with a proportional–integral–derivative controller tuned by the Ziegler–Nichols method, whose electricity use follows a vapour-compression cycle. The numerical solution was verified against analytical solutions, an independent implicit solver and energy-closure checks. Driven by measured weather for 10–16 June 2025, the green roof reduced the weekly cooling electricity from 163.3 to 133.3 kWh (18.4%), the peak electric demand by 22% and the roof heat gain by 66%, and avoided the capacity saturation of the conventional building. The added thermal resistance of the green-roof layers accounted for 16.3 percentage points of the saving, evapotranspiration for 3.4 points and photosynthesis for 0.6 points, whereas the canopy optical properties cost 1.8 points. A global sensitivity analysis gave a 5–95% range of 15.1–23.2% for the saving; the green-layer conductivity model, the sky temperature, the crop coefficient and the set point were the most influential inputs. The green roof required 455 L of irrigation water per week.

Authors

Publication Details

Journal
Preprints.org
Published
2026-10-26
DOI
https://doi.org/10.20944/preprints202610.2517.v1
Primary Topic
Urban Heat Island Mitigation
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Thermal Performance and Cooling-Energy Savings of Green Roofs in a Hot-Desert Climate: A Verified Coupled Envelope–HVAC Model for Mexicali, Mexico

Érick Gilberto Espinosa Martínez, Sergio Quezada García, M. Azucena Escobedo Izquierdo, Xochitl M. Zapata Morales
Preprints.org
Urban Heat Island Mitigation
preprint

Thermal Performance and Cooling-Energy Savings of Green Roofs in a Hot-Desert Climate: A Verified Coupled Envelope–HVAC Model for Mexicali, Mexico

Érick Gilberto Espinosa Martínez, Sergio Quezada García, M. Azucena Escobedo Izquierdo, Xochitl M. Zapata Morales
preprint en

Abstract

The cooling benefit of green roofs in the extreme heat of northern Mexico has rarely been quantified with dynamic models that couple the envelope with a controlled air-conditioning system. This study develops such a model for a 4 m × 4 m × 3 m concrete mini-building in Mexicali, Mexico (hot-desert climate), and compares a bare 0.15 m concrete roof with the same slab covered by a green roof. The model couples one-dimensional conduction through the roof and four walls, orientation-specific solar irradiance, evapotranspiration and photosynthesis sinks, a dynamic indoor-air balance and an inverter air conditioner with a proportional–integral–derivative controller tuned by the Ziegler–Nichols method, whose electricity use follows a vapour-compression cycle. The numerical solution was verified against analytical solutions, an independent implicit solver and energy-closure checks. Driven by measured weather for 10–16 June 2025, the green roof reduced the weekly cooling electricity from 163.3 to 133.3 kWh (18.4%), the peak electric demand by 22% and the roof heat gain by 66%, and avoided the capacity saturation of the conventional building. The added thermal resistance of the green-roof layers accounted for 16.3 percentage points of the saving, evapotranspiration for 3.4 points and photosynthesis for 0.6 points, whereas the canopy optical properties cost 1.8 points. A global sensitivity analysis gave a 5–95% range of 15.1–23.2% for the saving; the green-layer conductivity model, the sky temperature, the crop coefficient and the set point were the most influential inputs. The green roof required 455 L of irrigation water per week.

Preprints.org
Urban Heat Island Mitigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon