Metric-driven Pre-acquisition Diagnostics for Automated Microscopy Ultraviolet Surface Excitation (MUSE)

Background Automated microscopy enables large-scale tiled imaging but remains sensitive to variations in alignment, illumination, focus, and sample coverage that may only be detected after acquisition. We present an adaptive pre-acquisition quality-control framework for microscopy ultraviolet surface excitation (MUSE) that uses sparse scout imaging and tile-level metrics to guide acquisition and selective rescanning. Methods The framework quantifies brightness, dynamic range, focus, tissue fraction, and exposure error across the field of view. For example, in a representative 10 × 10 acquisition (100 tiles, 20-megapixel imagery), the mean p99 brightness was 0.525 (CV 10.4%), the mean dynamic range was 0.331, the median focus score was 0.0333, and the median tissue fraction was 0.943. Furthermore, applying a conservative exposure-error threshold (|error| > 0.25) identified 25% of tiles as rescan candidates. Results These results show that compact tile-level metrics can be converted into actionable quality gates, enabling early detection of local acquisition errors and targeted rescanning to improve mosaic consistency while minimizing unnecessary acquisition.

Authors

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-10-27
DOI
https://doi.org/10.64898/2026.10.22.760904
Primary Topic
Image Processing Techniques and Applications
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Metric-driven Pre-acquisition Diagnostics for Automated Microscopy Ultraviolet Surface Excitation (MUSE)

Bryan Davies, Matthew Nunez
bioRxiv (Cold Spring Harbor Laboratory)
Image Processing Techniques and Applications
preprint

Metric-driven Pre-acquisition Diagnostics for Automated Microscopy Ultraviolet Surface Excitation (MUSE)

Bryan Davies, Matthew Nunez
preprint en

Abstract

Background Automated microscopy enables large-scale tiled imaging but remains sensitive to variations in alignment, illumination, focus, and sample coverage that may only be detected after acquisition. We present an adaptive pre-acquisition quality-control framework for microscopy ultraviolet surface excitation (MUSE) that uses sparse scout imaging and tile-level metrics to guide acquisition and selective rescanning. Methods The framework quantifies brightness, dynamic range, focus, tissue fraction, and exposure error across the field of view. For example, in a representative 10 × 10 acquisition (100 tiles, 20-megapixel imagery), the mean p99 brightness was 0.525 (CV 10.4%), the mean dynamic range was 0.331, the median focus score was 0.0333, and the median tissue fraction was 0.943. Furthermore, applying a conservative exposure-error threshold (|error| > 0.25) identified 25% of tiles as rescan candidates. Results These results show that compact tile-level metrics can be converted into actionable quality gates, enabling early detection of local acquisition errors and targeted rescanning to improve mosaic consistency while minimizing unnecessary acquisition.

bioRxiv (Cold Spring Harbor Laboratory)
Image Processing Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon