Advances in Miniaturized Implantable Antennas for Biomedical Telemetry: A Review and Comparative Analysis

The diversity of implantable medical devices (IMDs) has led to a variety of antenna topologies. The miniaturization of these antennas has consequences primarily affecting parameters such as the gain, penetration depth, and specific absorption rate (SAR), power handling and link margin. Given the increasing number and diversity of currently existing miniaturized implantable antenna topologies, it is time to synthesize the literature. In response to this need, this work groups recent designs into three topology classes: form-based, spatial-based, and function-based. This classification is necessary and useful as it allows for the evaluation of important design considerations. With the application of this classification, we identify the representative designs in each class and then compare them to identify future research directions. The representative form-based design achieves the smallest footprint (1.59 mm3) and offers circular polarization (CP), but it suffers from low realized gain (−30.1 to −31.9 dBi) and high SAR (439–534 W/kg), with experimental validation reported at an implantation depth of 4 mm in a tissue-equivalent head phantom. The representative spatial-based multiple-input multiple-output (MIMO) design improves isolation (31.78 dB) and supports higher data rates (120 Mbps) with moderate SAR (52.3 W/kg) at a reported depth of 50 mm in minced meat, but requires a larger footprint (5.6 mm3). In comparison, the representative functional-based duplexing design achieves a relatively high realized gain (−20.2 to −20.3 dBi), a validated implantation depth of 65 mm in minced meat, and high isolation (29.5 dB). Despite recent advances, implantable antenna performance remains constrained by tissue loss, SAR, miniaturization, isolation, flexible integration, and communication range. Yet link-budget analysis shows all topologies achieve a 5–20 m range at a 10 dB margin, confirming tissue loss and SAR as the overriding bottlenecks. To address these issues, it will be necessary to utilize the most advanced decoupling techniques, low-loss biocompatible materials, and performance-driven system optimization to develop safe, compact, high-performance implantable wireless systems for advanced biomedical telemetry applications.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-10-27
DOI
https://doi.org/10.3390/electronics15214963
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advances in Miniaturized Implantable Antennas for Biomedical Telemetry: A Review and Comparative Analysis

Mohammed M. Bait‐Suwailam, Abdelhalim Chaabane
2 links
Electronics
Wireless Body Area Networks
article

Advances in Miniaturized Implantable Antennas for Biomedical Telemetry: A Review and Comparative Analysis

Mohammed M. Bait‐Suwailam, Abdelhalim Chaabane
article en

Abstract

The diversity of implantable medical devices (IMDs) has led to a variety of antenna topologies. The miniaturization of these antennas has consequences primarily affecting parameters such as the gain, penetration depth, and specific absorption rate (SAR), power handling and link margin. Given the increasing number and diversity of currently existing miniaturized implantable antenna topologies, it is time to synthesize the literature. In response to this need, this work groups recent designs into three topology classes: form-based, spatial-based, and function-based. This classification is necessary and useful as it allows for the evaluation of important design considerations. With the application of this classification, we identify the representative designs in each class and then compare them to identify future research directions. The representative form-based design achieves the smallest footprint (1.59 mm3) and offers circular polarization (CP), but it suffers from low realized gain (−30.1 to −31.9 dBi) and high SAR (439–534 W/kg), with experimental validation reported at an implantation depth of 4 mm in a tissue-equivalent head phantom. The representative spatial-based multiple-input multiple-output (MIMO) design improves isolation (31.78 dB) and supports higher data rates (120 Mbps) with moderate SAR (52.3 W/kg) at a reported depth of 50 mm in minced meat, but requires a larger footprint (5.6 mm3). In comparison, the representative functional-based duplexing design achieves a relatively high realized gain (−20.2 to −20.3 dBi), a validated implantation depth of 65 mm in minced meat, and high isolation (29.5 dB). Despite recent advances, implantable antenna performance remains constrained by tissue loss, SAR, miniaturization, isolation, flexible integration, and communication range. Yet link-budget analysis shows all topologies achieve a 5–20 m range at a 10 dB margin, confirming tissue loss and SAR as the overriding bottlenecks. To address these issues, it will be necessary to utilize the most advanced decoupling techniques, low-loss biocompatible materials, and performance-driven system optimization to develop safe, compact, high-performance implantable wireless systems for advanced biomedical telemetry applications.

ElectronicsVol. 15(21)
University Ferhat Abbas of Setif (DZ), Sultan Qaboos University (OM)
Good health and well-being
Openalex Percentile: Top 25%
Wireless Body Area Networks
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon