Heart rate and blood pressure variability, and baroreflex sensitivity, during heat exposure in persons with type 2 diabetes and hypertension

The autonomic nervous system regulates cardiovascular homeostasis during stressors such as heat, but the effects of type 2 diabetes (T2D) with hypertension on such responses are unclear. Twenty male participants (10 with type 2 diabetes and hypertension and 10 age-matched healthy controls; mean ages 64 ± 4.14 and 63 ± 5.42 years) underwent a 90-minute whole-body heat exposure at 40 °C and 50% relative humidity. Heart rate variability (HRV), baroreflex sensitivity (BRS), and blood pressure variability (BPV) were assessed before, during and after the heat exposure. Heat exposure increased heart rate in both groups but this response was less in T2D (5.43 bpm; ~ 7% increase) versus controls (13.96 bpm; ~ 22% increase; p = 0.014). Similarly, reductions in HRV indices to heat stress were generally smaller in magnitude among participants with T2D. For example, high-frequency power (HF RR) decreased by 31.21 ms² (~54.5% reduction) in T2D because of heat exposure, compared with a reduction of 179.35 ms² (~74% reduction) in controls (p = 0.038). Further, LF BRS decreased by 1.07 ms/mmHg (~25% reduction) vs. 3.96 ms/mmHg (~51% reduction) (p = 0.021), HF BRS by 1.58 ms/mmHg (~35% reduction) vs. 4.15 ms/mmHg (~62% reduction) (p = 0.034), and mean BRS by 1.18 ms/mmHg (~26% reduction) vs. 4.16 ms/mmHg (~58% reduction) (p = 0.010) in those with T2D versus controls, respectively. Low-frequency power (LF RR), LF/HF ratio and BPV parameters also showed smaller (though nonsignificant) changes in T2D. Overall, combined T2D and hypertension produced blunted autonomic responses to short-term heat exposure, potentially increasing vulnerability to temperature extremes.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-10-27
DOI
https://doi.org/10.1371/journal.pone.0361367
Primary Topic
Heart Rate Variability and Autonomic Control
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heart rate and blood pressure variability, and baroreflex sensitivity, during heat exposure in persons with type 2 diabetes and hypertension

Anje Christina Höper, Erlend Hoftun Farbu, Mojdeh Rafieian, Henna Hyrkäs-Palmu et al.
1 links
PLoS ONE
Heart Rate Variability and Autonomic Control
article

Heart rate and blood pressure variability, and baroreflex sensitivity, during heat exposure in persons with type 2 diabetes and hypertension

Anje Christina Höper, Erlend Hoftun Farbu, Mojdeh Rafieian, Henna Hyrkäs-Palmu, Rasmus I. P. Valtonen, Craig G. Crandall, Tiina Maria Ikäheimo, Mika Kallio
article en

Abstract

The autonomic nervous system regulates cardiovascular homeostasis during stressors such as heat, but the effects of type 2 diabetes (T2D) with hypertension on such responses are unclear. Twenty male participants (10 with type 2 diabetes and hypertension and 10 age-matched healthy controls; mean ages 64 ± 4.14 and 63 ± 5.42 years) underwent a 90-minute whole-body heat exposure at 40 °C and 50% relative humidity. Heart rate variability (HRV), baroreflex sensitivity (BRS), and blood pressure variability (BPV) were assessed before, during and after the heat exposure. Heat exposure increased heart rate in both groups but this response was less in T2D (5.43 bpm; ~ 7% increase) versus controls (13.96 bpm; ~ 22% increase; p = 0.014). Similarly, reductions in HRV indices to heat stress were generally smaller in magnitude among participants with T2D. For example, high-frequency power (HF RR) decreased by 31.21 ms² (~54.5% reduction) in T2D because of heat exposure, compared with a reduction of 179.35 ms² (~74% reduction) in controls (p = 0.038). Further, LF BRS decreased by 1.07 ms/mmHg (~25% reduction) vs. 3.96 ms/mmHg (~51% reduction) (p = 0.021), HF BRS by 1.58 ms/mmHg (~35% reduction) vs. 4.15 ms/mmHg (~62% reduction) (p = 0.034), and mean BRS by 1.18 ms/mmHg (~26% reduction) vs. 4.16 ms/mmHg (~58% reduction) (p = 0.010) in those with T2D versus controls, respectively. Low-frequency power (LF RR), LF/HF ratio and BPV parameters also showed smaller (though nonsignificant) changes in T2D. Overall, combined T2D and hypertension produced blunted autonomic responses to short-term heat exposure, potentially increasing vulnerability to temperature extremes.

PLoS ONEVol. 21(10)
University Hospital of North Norway (NO), Oulu University Hospital (FI), Texas Health Dallas (US), UiT The Arctic University of Norway (NO), The University of Texas Southwestern Medical Center (US), University of Oulu (FI)
Juho Vainion Säätiö
Good health and well-being
Openalex Percentile: Top 11%
Heart Rate Variability and Autonomic Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon