Synthetic-to-Real 5D Pose Estimation for Acoustically Levitated Micro-Calibrators in Lab-on-a-Chip Devices

Established acoustofluidic lab-on-a-chip devices enable contactless, label-free trapping of cells, but do not provide a quantitative readout of a levitated sample’s orientation, restricting their analytical reach. We present a synthetic-to-real deep learning framework that addresses this gap by estimating the five-dimensional (5D) pose of a trident-shaped micro-calibrator co-trapped with the cells. Here, 5D pose denotes the two-dimensional (2D) bounding-box center in the image plane and the calibrator’s three-dimensional (3D) orientation. Printed by two-photon polymerization with 10, 15, and 20 μm arms, the calibrator provides the rigid, asymmetric geometry that a translucent, deformable spheroid lacks. The framework cascades detection, foreground segmentation, and rotation regression, with the normalized bounding-box center as a positional auxiliary input, and optionally applies temporal smoothing; it is trained on domain-randomized renderings, eliminating manual 3D pose annotation. On 15,000 synthetic test images, it reached a mean geodesic rotation error of 0.82°. The ablation study showed that the positional input substantially improves rotation estimation and background removal further lowers the error, and identified segmentation, not detection, as the dominant upstream error source. Pseudo-label adaptation raised the expert-assessed correctness rate from 34.71% to 83.62% on 5281 real microscopy frames from which the pseudo-labels were drawn (adaptation performance) and from 2.48% to 29.34% on 242 held-out fluorescence frames with adherent cells (generalization performance). This demonstrates the feasibility of a calibrator-based orientation readout on an established acoustofluidic platform without hardware change.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2026-10-27
DOI
https://doi.org/10.3390/mi17111231
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synthetic-to-Real 5D Pose Estimation for Acoustically Levitated Micro-Calibrators in Lab-on-a-Chip Devices

Yasemin Geiger, Oliver Hayden, Stefanie Sudhop, Benedikt Kaufmann et al.
1 links
Micromachines
Microfluidic and Bio-sensing Technologies
article

Synthetic-to-Real 5D Pose Estimation for Acoustically Levitated Micro-Calibrators in Lab-on-a-Chip Devices

Yasemin Geiger, Oliver Hayden, Stefanie Sudhop, Benedikt Kaufmann, Eckehard G. Steinbach, Zhijin Li, Shilpi Pandey, Dilan Kılıç, Valentina Leone, Zongxie Chen, Matthias E. Rebhan
article en

Abstract

Established acoustofluidic lab-on-a-chip devices enable contactless, label-free trapping of cells, but do not provide a quantitative readout of a levitated sample’s orientation, restricting their analytical reach. We present a synthetic-to-real deep learning framework that addresses this gap by estimating the five-dimensional (5D) pose of a trident-shaped micro-calibrator co-trapped with the cells. Here, 5D pose denotes the two-dimensional (2D) bounding-box center in the image plane and the calibrator’s three-dimensional (3D) orientation. Printed by two-photon polymerization with 10, 15, and 20 μm arms, the calibrator provides the rigid, asymmetric geometry that a translucent, deformable spheroid lacks. The framework cascades detection, foreground segmentation, and rotation regression, with the normalized bounding-box center as a positional auxiliary input, and optionally applies temporal smoothing; it is trained on domain-randomized renderings, eliminating manual 3D pose annotation. On 15,000 synthetic test images, it reached a mean geodesic rotation error of 0.82°. The ablation study showed that the positional input substantially improves rotation estimation and background removal further lowers the error, and identified segmentation, not detection, as the dominant upstream error source. Pseudo-label adaptation raised the expert-assessed correctness rate from 34.71% to 83.62% on 5281 real microscopy frames from which the pseudo-labels were drawn (adaptation performance) and from 2.48% to 29.34% on 242 held-out fluorescence frames with adherent cells (generalization performance). This demonstrates the feasibility of a calibrator-based orientation readout on an established acoustofluidic platform without hardware change.

MicromachinesVol. 17(11)
Munich University of Applied Sciences (DE), TUM Klinikum (DE), Technical University of Munich (DE)
Deutsche Forschungsgemeinschaft, China Scholarship Council
Openalex Percentile: Top 25%
Microfluidic and Bio-sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon