Stable 2-year migration on radiostereometric analysis and improved gait speed and function after bicruciate-retaining TKA: a prospective cohort of 25 patients

BACKGROUND AND PURPOSE: In bicruciate-retaining total knee arthroplasty (BCR TKA) the preservation of both cruciate ligaments necessitates a different tibial tray design with reduced bone-implant interface. These ligaments also influence knee joint force dynamics and may thereby affect component migration. The primary aim of our study was to assess the fixation of BCR TKA up to 2 years postoperatively. Secondary aims included the evaluation of clinical and functional outcomes. METHODS: This prospective study (https://osf.io/zqt8d) included 25 BCR TKA patients. Migration of both components was assessed at different follow-up time points by model-based radiostereometric analysis (RSA) using bone markers. Primary outcome was total translation (TT) and total rotation (TR) at the 2-year follow-up. Secondary outcomes included at-home gait parameters (gait speed, stride length, stride time) assessed with wearable sensors, patient-reported outcome measures (PROMs), and adverse events (AEs). RESULTS: At the 2-year follow-up, least-squares mean tibial TT was 0.22 mm (95% confidence interval [CI] 0.16-0.28) (tibia) and femoral TT 0.43 mm (CI 0.30-0.57). The least-squares mean tibial TR was 0.53° (CI 0.43-0.63) and femoral TR 0.64° (CI 0.46-0.82). PROMs improved significantly after surgery, with improvements exceeding the predefined minimal clinically important difference (MCID). Gait outcomes revealed a significant gait speed improvement, which remained below MCID, and no significant difference from healthy controls 1 year postoperatively. AEs included 2 intraoperative tibial eminence fractures, 4 cases of persistent postoperative pain, and 2 cases of postoperative oedema with temporary knee stiffness. CONCLUSION: RSA analysis of this BCR TKA demonstrated a stabilizing migration pattern that remained below established TKA benchmark values (for different designs), indicating good fixation at 2-year follow-up. The findings were accompanied by an improved PROM, whereas gait speed improvement was below MCID.

Authors

Institutions

Publication Details

Journal
Acta Orthopaedica
Published
2026-10-26
DOI
https://doi.org/10.2340/17453674.2026.46950
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stable 2-year migration on radiostereometric analysis and improved gait speed and function after bicruciate-retaining TKA: a prospective cohort of 25 patients

Kelly Mills, Koen C. Defoort, Saskia Susan, Simon Nurettin van Laarhoven et al.
Acta Orthopaedica
Total Knee Arthroplasty Outcomes
article

Stable 2-year migration on radiostereometric analysis and improved gait speed and function after bicruciate-retaining TKA: a prospective cohort of 25 patients

Kelly Mills, Koen C. Defoort, Saskia Susan, Simon Nurettin van Laarhoven, Petra J. C. Heesterbeek
article en

Abstract

BACKGROUND AND PURPOSE: In bicruciate-retaining total knee arthroplasty (BCR TKA) the preservation of both cruciate ligaments necessitates a different tibial tray design with reduced bone-implant interface. These ligaments also influence knee joint force dynamics and may thereby affect component migration. The primary aim of our study was to assess the fixation of BCR TKA up to 2 years postoperatively. Secondary aims included the evaluation of clinical and functional outcomes. METHODS: This prospective study (https://osf.io/zqt8d) included 25 BCR TKA patients. Migration of both components was assessed at different follow-up time points by model-based radiostereometric analysis (RSA) using bone markers. Primary outcome was total translation (TT) and total rotation (TR) at the 2-year follow-up. Secondary outcomes included at-home gait parameters (gait speed, stride length, stride time) assessed with wearable sensors, patient-reported outcome measures (PROMs), and adverse events (AEs). RESULTS: At the 2-year follow-up, least-squares mean tibial TT was 0.22 mm (95% confidence interval [CI] 0.16-0.28) (tibia) and femoral TT 0.43 mm (CI 0.30-0.57). The least-squares mean tibial TR was 0.53° (CI 0.43-0.63) and femoral TR 0.64° (CI 0.46-0.82). PROMs improved significantly after surgery, with improvements exceeding the predefined minimal clinically important difference (MCID). Gait outcomes revealed a significant gait speed improvement, which remained below MCID, and no significant difference from healthy controls 1 year postoperatively. AEs included 2 intraoperative tibial eminence fractures, 4 cases of persistent postoperative pain, and 2 cases of postoperative oedema with temporary knee stiffness. CONCLUSION: RSA analysis of this BCR TKA demonstrated a stabilizing migration pattern that remained below established TKA benchmark values (for different designs), indicating good fixation at 2-year follow-up. The findings were accompanied by an improved PROM, whereas gait speed improvement was below MCID.

Acta OrthopaedicaVol. 97
Sint Maartenskliniek (NL)
Openalex Percentile: Top 10%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon