A retrospective analysis of tidal breathing pulmonary function characteristics in infants and young children with recurrent wheezing

Background Recurrent wheezing is common in infants and young children, but objective lung function assessment is limited because conventional spirometry is often not feasible. Tidal breathing pulmonary function testing may help characterize expiratory flow abnormalities in this age group. Objective To evaluate tidal breathing pulmonary function characteristics in infants and young children with recurrent wheezing. Methods This retrospective study included 178 children who underwent tidal breathing pulmonary function testing from March 2025 to March 2026, including 120 with recurrent wheezing and 58 non-wheezing controls. Core indices, abnormality patterns, multivariable logistic regression, sensitivity analyses, and exploratory ROC analysis were evaluated. Results Children with recurrent wheezing had a lower ratio of time to peak tidal expiratory flow to total expiratory time (tPTEF/tE) than non-wheezing controls, with a mean difference of −0.041 and P < 0.001. The ratio of volume to peak tidal expiratory flow to total expiratory volume (VPTEF/VE) was also lower in the recurrent wheezing group, with a mean difference of −0.045 and P < 0.001. Any tidal breathing pulmonary function abnormality was more frequent in the recurrent wheezing group than in controls, at 75.8% and 27.6%, respectively, P < 0.001. In a combined multivariable model including both core indices, higher tPTEF/tE and VPTEF/VE were independently associated with lower odds of recurrent wheezing, with adjusted ORs of 0.746 and 0.746 per 0.01 increase, respectively, both P < 0.001. Sensitivity analyses excluding premature infants, pneumonia cases, oxygen therapy, bronchodilator exposure, and lower-quality but analyzable tests showed consistent results. Exploratory ROC analysis showed moderate discriminatory ability, with AUCs of 0.779 for tPTEF/tE and 0.792 for VPTEF/VE. Conclusion Infants and young children with recurrent wheezing showed lower tPTEF/tE and VPTEF/VE, suggesting altered tidal expiratory breathing mechanics. These indices may provide supportive objective information for evaluating recurrent wheezing, but they should not be used as standalone diagnostic markers.

Authors

Publication Details

Journal
Frontiers in Pediatrics
Published
2026-10-26
DOI
https://doi.org/10.3389/fped.2026.1966843
Primary Topic
Asthma and respiratory diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A retrospective analysis of tidal breathing pulmonary function characteristics in infants and young children with recurrent wheezing

王艳敏, Huahua Tian, Qian Ding, Xiaowei Wang et al.
Frontiers in Pediatrics
Asthma and respiratory diseases
article

A retrospective analysis of tidal breathing pulmonary function characteristics in infants and young children with recurrent wheezing

王艳敏, Huahua Tian, Qian Ding, Xiaowei Wang, Jiao Chen
article en

Abstract

Background Recurrent wheezing is common in infants and young children, but objective lung function assessment is limited because conventional spirometry is often not feasible. Tidal breathing pulmonary function testing may help characterize expiratory flow abnormalities in this age group. Objective To evaluate tidal breathing pulmonary function characteristics in infants and young children with recurrent wheezing. Methods This retrospective study included 178 children who underwent tidal breathing pulmonary function testing from March 2025 to March 2026, including 120 with recurrent wheezing and 58 non-wheezing controls. Core indices, abnormality patterns, multivariable logistic regression, sensitivity analyses, and exploratory ROC analysis were evaluated. Results Children with recurrent wheezing had a lower ratio of time to peak tidal expiratory flow to total expiratory time (tPTEF/tE) than non-wheezing controls, with a mean difference of −0.041 and P < 0.001. The ratio of volume to peak tidal expiratory flow to total expiratory volume (VPTEF/VE) was also lower in the recurrent wheezing group, with a mean difference of −0.045 and P < 0.001. Any tidal breathing pulmonary function abnormality was more frequent in the recurrent wheezing group than in controls, at 75.8% and 27.6%, respectively, P < 0.001. In a combined multivariable model including both core indices, higher tPTEF/tE and VPTEF/VE were independently associated with lower odds of recurrent wheezing, with adjusted ORs of 0.746 and 0.746 per 0.01 increase, respectively, both P < 0.001. Sensitivity analyses excluding premature infants, pneumonia cases, oxygen therapy, bronchodilator exposure, and lower-quality but analyzable tests showed consistent results. Exploratory ROC analysis showed moderate discriminatory ability, with AUCs of 0.779 for tPTEF/tE and 0.792 for VPTEF/VE. Conclusion Infants and young children with recurrent wheezing showed lower tPTEF/tE and VPTEF/VE, suggesting altered tidal expiratory breathing mechanics. These indices may provide supportive objective information for evaluating recurrent wheezing, but they should not be used as standalone diagnostic markers.

Frontiers in PediatricsVol. 14
Openalex Percentile: Top 13%
Asthma and respiratory diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon