Comparison of Cumulative Dissipated Energy Between Two Phacoemulsification Systems Using a Modified Flip-and-Chop Technique With Multidirectional Jerking Movement From a Phacoemulsification Handpiece

IntroductionThe four-dimensional Unity phacoemulsification tip is designed to optimize tip motion and reduce time and energy consumption in cataract surgery.This study highlights a modified flip-and-chop technique with an added multidirectional jerking motion to the phacoemulsification handpiece intraocularly (referred to as the "five-dimensional flip-and-chop") and compares the cumulative dissipated energy (CDE) between the fourdimensional Unity system (Alcon Inc., Geneva, Switzerland) and the torsional Centurion system (Alcon Inc., Geneva, Switzerland) under this technique. MethodsThis is a retrospective, sequential, non-randomized comparison of 40 consecutive cases of Centurion to 40 consecutive cases of Unity performed by a single surgeon at a single ambulatory surgical suite.The initial cataract density between the groups was compared using optical coherence tomography (OCT) image quality (IQ) values from a single Maestro 2 device (Topcon, Tokyo, Japan). ResultsThe two groups had comparable mean ages, sex distributions, and IQs.The mean CDE was significantly lower in the Unity group (5.39; SD=2.8) than in the Centurion group (8.23; SD=5.9), with p=0.0075. ConclusionUtilizing the modified "five-dimensional flip-and-chop" technique, the four-dimensional Unity system produced significantly lower CDE than the torsional Centurion system.The addition of this technique to the phacoemulsification handpiece may further improve the efficiency of phacoemulsification.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2026-10-26
DOI
https://doi.org/10.7759/cureus.118645
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Cumulative Dissipated Energy Between Two Phacoemulsification Systems Using a Modified Flip-and-Chop Technique With Multidirectional Jerking Movement From a Phacoemulsification Handpiece

Emily J. S. Kang, Ming Chen, Hung-Yuan Lin
Cureus
Intraocular Surgery and Lenses
article

Comparison of Cumulative Dissipated Energy Between Two Phacoemulsification Systems Using a Modified Flip-and-Chop Technique With Multidirectional Jerking Movement From a Phacoemulsification Handpiece

Emily J. S. Kang, Ming Chen, Hung-Yuan Lin
article en

Abstract

IntroductionThe four-dimensional Unity phacoemulsification tip is designed to optimize tip motion and reduce time and energy consumption in cataract surgery.This study highlights a modified flip-and-chop technique with an added multidirectional jerking motion to the phacoemulsification handpiece intraocularly (referred to as the "five-dimensional flip-and-chop") and compares the cumulative dissipated energy (CDE) between the fourdimensional Unity system (Alcon Inc., Geneva, Switzerland) and the torsional Centurion system (Alcon Inc., Geneva, Switzerland) under this technique. MethodsThis is a retrospective, sequential, non-randomized comparison of 40 consecutive cases of Centurion to 40 consecutive cases of Unity performed by a single surgeon at a single ambulatory surgical suite.The initial cataract density between the groups was compared using optical coherence tomography (OCT) image quality (IQ) values from a single Maestro 2 device (Topcon, Tokyo, Japan). ResultsThe two groups had comparable mean ages, sex distributions, and IQs.The mean CDE was significantly lower in the Unity group (5.39; SD=2.8) than in the Centurion group (8.23; SD=5.9), with p=0.0075. ConclusionUtilizing the modified "five-dimensional flip-and-chop" technique, the four-dimensional Unity system produced significantly lower CDE than the torsional Centurion system.The addition of this technique to the phacoemulsification handpiece may further improve the efficiency of phacoemulsification.

Cureus
University of Hawaiʻi at Mānoa (US)
Openalex Percentile: Top 8%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon