Post-market device experience reports of dorsal root ganglion stimulation: a 10-year retrospective analysis of the FDA MAUDE database

Background Dorsal root ganglion stimulation is an established therapy for focal neuropathic pain, including complex regional pain syndrome. Post-market adverse event data spanning the full post-approval decade are lacking. Methods We retrospectively analyzed dorsal root ganglion stimulation-related U.S. Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) reports (January 2016–May 2026). Records underwent multi-stage deduplication, combining a blinded manual review by four independent investigators with a custom two-stage algorithmic protocol to merge complex residual duplicates. Thematic analysis was performed using NVivo V.15. Results Following deduplication, 10 532 reports were included. 10 334 were reported as serious injuries. Among reports with documented sex (n = 4796), 60.2% were female. Age was reported in 4329 records, and the median was 44 years (IQR: 36–50). The USA contributed 88.4% of geographically identified reports. Most reported patient-related issues were “inadequate pain relief” (n=7135), followed by “failure of implant” (n=781), “implant pain” (n=548), and “cerebrospinal fluid leakage” (n=274). “Migration” was the most prevalent device problem code (n=2426), followed by “high impedance” (n=1560), “therapeutic or diagnostic output failure” (n=1167), and “fracture” (n=1160). Implant-year data were right-truncated. Conclusion Reported dorsal root ganglion stimulation events are dominated by lead migration, impedance abnormality, and fracture frequently co-presenting with persistence of symptoms. These patterns support engineering attention to lead fixation and structured hardware surveillance within routine follow-up. Because MAUDE lacks denominator data, results are signal generating. Prospective registries with implant-level denominators are needed to define true complication rates and distinguish hardware failure from programming-related efficacy loss.

Authors

Institutions

Publication Details

Journal
Regional Anesthesia & Pain Medicine
Published
2026-10-26
DOI
https://doi.org/10.1136/rapm-2026-108423
Primary Topic
Pain Management and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Post-market device experience reports of dorsal root ganglion stimulation: a 10-year retrospective analysis of the FDA MAUDE database

Yasmin Negida, Martin W. Gerges, Maya Magdy Abdelwahab, Yousef Hawas et al.
Regional Anesthesia & Pain Medicine
Pain Management and Treatment
article

Post-market device experience reports of dorsal root ganglion stimulation: a 10-year retrospective analysis of the FDA MAUDE database

Yasmin Negida, Martin W. Gerges, Maya Magdy Abdelwahab, Yousef Hawas, Ibraheem M. Alkhawaldeh, Ahmed Harb, Mubarak I. Abdalla, Mohamed Marouf
article en

Abstract

Background Dorsal root ganglion stimulation is an established therapy for focal neuropathic pain, including complex regional pain syndrome. Post-market adverse event data spanning the full post-approval decade are lacking. Methods We retrospectively analyzed dorsal root ganglion stimulation-related U.S. Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) reports (January 2016–May 2026). Records underwent multi-stage deduplication, combining a blinded manual review by four independent investigators with a custom two-stage algorithmic protocol to merge complex residual duplicates. Thematic analysis was performed using NVivo V.15. Results Following deduplication, 10 532 reports were included. 10 334 were reported as serious injuries. Among reports with documented sex (n = 4796), 60.2% were female. Age was reported in 4329 records, and the median was 44 years (IQR: 36–50). The USA contributed 88.4% of geographically identified reports. Most reported patient-related issues were “inadequate pain relief” (n=7135), followed by “failure of implant” (n=781), “implant pain” (n=548), and “cerebrospinal fluid leakage” (n=274). “Migration” was the most prevalent device problem code (n=2426), followed by “high impedance” (n=1560), “therapeutic or diagnostic output failure” (n=1167), and “fracture” (n=1160). Implant-year data were right-truncated. Conclusion Reported dorsal root ganglion stimulation events are dominated by lead migration, impedance abnormality, and fracture frequently co-presenting with persistence of symptoms. These patterns support engineering attention to lead fixation and structured hardware surveillance within routine follow-up. Because MAUDE lacks denominator data, results are signal generating. Prospective registries with implant-level denominators are needed to define true complication rates and distinguish hardware failure from programming-related efficacy loss.

Regional Anesthesia & Pain Medicine
Mansoura University (EG), Al-Azhar University (EG), Virginia Commonwealth University (US), Mutah University (JO), Tanta University (EG), Omdurman Islamic University (SD), Helwan University (EG)
Openalex Percentile: Top 8%
Pain Management and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon