A barcode-enabled distance-based paper sensor using silver chloranilate for semi-quantitative determination of chloride in various water sources

. The method exhibited adequate selectivity for the coexisting ions evaluated and yielded recoveries of 98.98-105.39% with RSD values not exceeding 5% in spiked water samples. Results obtained using the d-PAD were comparable to those obtained by Mohr titration, with relative errors ranging from 0.64% to 4.31%. Overall, the combined distance-based and barcode-assisted readouts provide a simple and portable platform for point-of-need chloride analysis in water samples.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2026-11-26
DOI
https://doi.org/10.1039/d6ay01764a
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A barcode-enabled distance-based paper sensor using silver chloranilate for semi-quantitative determination of chloride in various water sources

Nutthaporn Malahom, Niyada Khunkhong, Rattapol Meelapsom, Daniel Citterio et al.
Analytical Methods
Biosensors and Analytical Detection
article

A barcode-enabled distance-based paper sensor using silver chloranilate for semi-quantitative determination of chloride in various water sources

Nutthaporn Malahom, Niyada Khunkhong, Rattapol Meelapsom, Daniel Citterio, Yanawut Manmana, Purim Jarujamrus, Thanaporn Songsaard, Thunwarat Sudchada, Rakfan Phothi
article en

Abstract

. The method exhibited adequate selectivity for the coexisting ions evaluated and yielded recoveries of 98.98-105.39% with RSD values not exceeding 5% in spiked water samples. Results obtained using the d-PAD were comparable to those obtained by Mohr titration, with relative errors ranging from 0.64% to 4.31%. Overall, the combined distance-based and barcode-assisted readouts provide a simple and portable platform for point-of-need chloride analysis in water samples.

Analytical MethodsVol. 18(45)
Keio University (JP), Kalasin University (TH), Ratchathani University (TH), King Mongkut's University of Technology Thonburi (TH), Ubon Ratchathani University (TH), Walailak University (TH)
National Research Council of Thailand
Clean water and sanitation
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
A barcode-enabled distance-based paper sensor using silver chloranilate for semi-quantitative determination of chloride in various water sources — Nutthaporn Malahom, Niyada Khunkhong, et al. · Analytical Methods (2026) | TGRS Research Map | TGRS