Low‐dose CT denoising using a diffusion prior via score distillation sampling

BACKGROUND: Low-dose computed tomography (LDCT) reduces radiation exposure but amplifies noise, which can degrade diagnostic reliability. Recent studies have applied diffusion-based models to LDCT denoising and shown promising performance. However, many of these approaches require paired LDCT and normal-dose CT (NDCT) data or dose-specific retraining, and their reconstruction procedures are often strictly coupled to a predefined diffusion trajectory. PURPOSE: This study proposes an optimization-based LDCT denoising framework that uses a pre-trained NDCT diffusion model as an image prior and can be applied across various dose levels without dose-specific retraining. METHODS: We formulate LDCT denoising as an optimization problem guided by a pre-trained score-based generative model (SGM) trained only on NDCT images. The Poisson data fidelity term enforces consistency with the measured projection data, whereas the score distillation sampling (SDS) term acts as a regularizer that guides the reconstruction toward the NDCT distribution learned by the pre-trained SGM. The denoised image is obtained by iteratively optimizing a projection-domain residual variable using the combined Poisson data fidelity gradient and SDS-based regularization gradient. RESULTS: The proposed method effectively suppressed noise while preserving fine anatomical structures across multiple dose levels using a single pre-trained diffusion model. Quantitative evaluations with respect to full-dose reference images and visual comparisons demonstrated competitive performance compared with supervised and self-supervised LDCT denoising baselines. CONCLUSIONS: The results show that diffusion-based image priors can be leveraged across various low-dose levels within the proposed optimization-based denoising framework. Our work suggests that SDS-guided diffusion priors are a promising direction for LDCT denoising in data-limited settings.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2026-10-26
DOI
https://doi.org/10.1002/mp.70707
Primary Topic
Image and Signal Denoising Methods
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low‐dose CT denoising using a diffusion prior via score distillation sampling

Jooho Lee, Jongduk Baek, Hojin Jung
Medical Physics
Image and Signal Denoising Methods
article

Low‐dose CT denoising using a diffusion prior via score distillation sampling

Jooho Lee, Jongduk Baek, Hojin Jung
article en

Abstract

BACKGROUND: Low-dose computed tomography (LDCT) reduces radiation exposure but amplifies noise, which can degrade diagnostic reliability. Recent studies have applied diffusion-based models to LDCT denoising and shown promising performance. However, many of these approaches require paired LDCT and normal-dose CT (NDCT) data or dose-specific retraining, and their reconstruction procedures are often strictly coupled to a predefined diffusion trajectory. PURPOSE: This study proposes an optimization-based LDCT denoising framework that uses a pre-trained NDCT diffusion model as an image prior and can be applied across various dose levels without dose-specific retraining. METHODS: We formulate LDCT denoising as an optimization problem guided by a pre-trained score-based generative model (SGM) trained only on NDCT images. The Poisson data fidelity term enforces consistency with the measured projection data, whereas the score distillation sampling (SDS) term acts as a regularizer that guides the reconstruction toward the NDCT distribution learned by the pre-trained SGM. The denoised image is obtained by iteratively optimizing a projection-domain residual variable using the combined Poisson data fidelity gradient and SDS-based regularization gradient. RESULTS: The proposed method effectively suppressed noise while preserving fine anatomical structures across multiple dose levels using a single pre-trained diffusion model. Quantitative evaluations with respect to full-dose reference images and visual comparisons demonstrated competitive performance compared with supervised and self-supervised LDCT denoising baselines. CONCLUSIONS: The results show that diffusion-based image priors can be leveraged across various low-dose levels within the proposed optimization-based denoising framework. Our work suggests that SDS-guided diffusion priors are a promising direction for LDCT denoising in data-limited settings.

Medical PhysicsVol. 53(11)
Yonsei University (KR)
National Research Foundation of Korea
Openalex Percentile: Top 17%
Image and Signal Denoising Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon