Soiling, cleaning frequency, and oversizing of pole-mounted photovoltaic configurations in arid climates

This paper presents an experimental assessment of soiling effects, cleaning requirements, and design implications for pole-integrated off-grid photovoltaic systems in arid environments, with emphasis on low-maintainability installations, where cleaning is impractical and soiling is a major concern. This study is based on a one-year field measurement campaign at the Qatar Environment and Energy Research Institute's Outdoor Test Facility in Doha, Qatar. Five photovoltaic configurations are evaluated simultaneously under identical conditions: 22°-tilted back-contact, 22°-tilted bifacial, vertical back-contact, vertical bifacial, and octagonal Vertical Photovoltaic Tube modules. The key metrics are the effective soiling loss, the threshold-based cleaning frequency, and the capacity oversizing factor that compensates soiling when cleaning is not possible. Since optical sensor-based instrumental soiling data exists only for the tilted reference plane, image-based scaling factors are applied to estimate the soiling in the other configurations. The results show a geometry-dependent soiling hierarchy. Tilted configurations require approximately 19 threshold-triggered cleanings per year; if they are never cleaned, they need 1.7% (best month) to 66.4% (worst month, reconstructed) additional capacity, and 14.2% under typical (campaign-mean) conditions. Vertical configurations require one to two cleanings per year and 0.3–6.4% additional capacity. The Vertical Photovoltaic Tube triggered no cleaning in the observed year and has an estimated 0.1–2.0% additional capacity (soiling estimated from image-based factors). These findings indicate that soiling resilience is a principal design advantage of the Vertical Photovoltaic Tube for remote, low-maintenance deployments, and they provide design guidance on module geometry, cleaning strategy, and system sizing in hot-arid climates.

Authors

Institutions

Publication Details

Journal
Solar Energy
Published
2026-10-26
DOI
https://doi.org/10.1016/j.solener.2026.115261
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Soiling, cleaning frequency, and oversizing of pole-mounted photovoltaic configurations in arid climates

Yusuf Biçer, Dhanup Somasekharan Pillai, Tareq A. Al‐Ansari, Khaled A’amar
Solar Energy
Solar Thermal and Photovoltaic Systems
article

Soiling, cleaning frequency, and oversizing of pole-mounted photovoltaic configurations in arid climates

Yusuf Biçer, Dhanup Somasekharan Pillai, Tareq A. Al‐Ansari, Khaled A’amar
article en

Abstract

This paper presents an experimental assessment of soiling effects, cleaning requirements, and design implications for pole-integrated off-grid photovoltaic systems in arid environments, with emphasis on low-maintainability installations, where cleaning is impractical and soiling is a major concern. This study is based on a one-year field measurement campaign at the Qatar Environment and Energy Research Institute's Outdoor Test Facility in Doha, Qatar. Five photovoltaic configurations are evaluated simultaneously under identical conditions: 22°-tilted back-contact, 22°-tilted bifacial, vertical back-contact, vertical bifacial, and octagonal Vertical Photovoltaic Tube modules. The key metrics are the effective soiling loss, the threshold-based cleaning frequency, and the capacity oversizing factor that compensates soiling when cleaning is not possible. Since optical sensor-based instrumental soiling data exists only for the tilted reference plane, image-based scaling factors are applied to estimate the soiling in the other configurations. The results show a geometry-dependent soiling hierarchy. Tilted configurations require approximately 19 threshold-triggered cleanings per year; if they are never cleaned, they need 1.7% (best month) to 66.4% (worst month, reconstructed) additional capacity, and 14.2% under typical (campaign-mean) conditions. Vertical configurations require one to two cleanings per year and 0.3–6.4% additional capacity. The Vertical Photovoltaic Tube triggered no cleaning in the observed year and has an estimated 0.1–2.0% additional capacity (soiling estimated from image-based factors). These findings indicate that soiling resilience is a principal design advantage of the Vertical Photovoltaic Tube for remote, low-maintenance deployments, and they provide design guidance on module geometry, cleaning strategy, and system sizing in hot-arid climates.

Solar EnergyVol. 320
Hamad bin Khalifa University (QA)
Qatar National Research Fund, Qatar National Library
Openalex Percentile: Top 35%
Solar Thermal and Photovoltaic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon