Fibrinolysis resistance in sepsis assessed by serial beside viscoelastometry is associated with plasma protein profiles and organ- failure severity: a prospective observational study

Background: Fibrinolysis resistance is associated with adverse outcomes in sepsis and can be quantified at the bedside by tissue plasminogen activator-enhanced viscoelastometric testing, using the fibrin-adjusted (FIBA10) clot lysis time (TPA-LT) expressed as the TPA-LT/FIBA10 ratio. In this study of adults admitted to intensive care with sepsis, plasma tissue plasminogen activator activity, plasminogen activator inhibitor-1 activity (PAI-1), plasminogen and a2-antiplasmin were measured serially alongside TPA-LT/FIBA10 and Sequential Organ Failure Assessment (SOFA-2) scores. Whether the bedside TPA-LT/FIBA10 measure of fibrinolysis resistance reflects the underlying plasma fibrinolytic protein environment, and whether it tracks organ-failure severity, has not been established. Results: This prospective observational study included 283 paired observations in 69 septic patients admitted with a median Acute Physiology and Chronic Health Evaluation III score 81, median SOFA-2 score 13 and a 38% ICU mortality. PAI-1 increased and plasminogen decreased with increasing fibrinolysis resistance (1.77 [1.50-2.09]-fold increase and 0.81 [0.76-0.87]-fold decrease, respectively, per e-fold increase in TPA-LT/FIBA10). Increasing organ-failure severity was also associated with increased PAI-1 and decreased plasminogen (1.23 [1.17-1.29]-fold increase and 0.95 [0.93-0.96]-fold decrease, respectively, per point increase in SOFA-2). In contrast, tissue plasminogen activator activity and absolute a2-antiplasmin did not relate to fibrinolysis resistance or organ failure. Principal component analysis of the fibrinolysis proteins, organ-failure severity and fibrinolysis resistance identified a dominant axis explaining 35% of the variance, on which PAI-1, SOFA-2 and TPA-LT/FIBA10 loaded together in opposition to plasminogen. Unsupervised clustering of the dataset, performed without reference to patient outcomes, separated a fibrinolysis inhibitor- high, substrate-depleted group with 61% mortality compared to 29% in the preserved- fibrinolysis group. During the ICU stay, PAI-1 decreased within 72 hours in survivors but remained unchanged in non-survivors (interaction p<0.001). A trend was observed for plasminogen levels increasing in survivors but remaining static in non-survivors. Conclusions: Changes in key fibrinolysis proteins, organ-failure severity and fibrinolysis resistance measured by viscoelastometry were coupled facets of the response to sepsis dominated by fibrinolysis inhibitor excess and substrate depletion rather than by reduced activator availability. These findings provide biological validation for bedside viscoelastometric quantification of fibrinolysis resistance and support prospective evaluation of substrate-directed profibrinolytic strategies.

Authors

Institutions

Publication Details

Journal
medRxiv
Published
2026-10-26
DOI
https://doi.org/10.64898/2026.10.24.26366401
Primary Topic
Sepsis Diagnosis and Treatment
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Fibrinolysis resistance in sepsis assessed by serial beside viscoelastometry is associated with plasma protein profiles and organ- failure severity: a prospective observational study

Lucy A. Coupland, David John Rabbolini, Philip Crispin, Anders Åneman et al.
medRxiv
Sepsis Diagnosis and Treatment
preprint

Fibrinolysis resistance in sepsis assessed by serial beside viscoelastometry is associated with plasma protein profiles and organ- failure severity: a prospective observational study

Lucy A. Coupland, David John Rabbolini, Philip Crispin, Anders Åneman, Robert Lindsay Medcalf, Eurwin Suryana, Matthew Self, Steve Frost, Peter Moore, Ruby Law, Charitani Keragala
preprint en

Abstract

Background: Fibrinolysis resistance is associated with adverse outcomes in sepsis and can be quantified at the bedside by tissue plasminogen activator-enhanced viscoelastometric testing, using the fibrin-adjusted (FIBA10) clot lysis time (TPA-LT) expressed as the TPA-LT/FIBA10 ratio. In this study of adults admitted to intensive care with sepsis, plasma tissue plasminogen activator activity, plasminogen activator inhibitor-1 activity (PAI-1), plasminogen and a2-antiplasmin were measured serially alongside TPA-LT/FIBA10 and Sequential Organ Failure Assessment (SOFA-2) scores. Whether the bedside TPA-LT/FIBA10 measure of fibrinolysis resistance reflects the underlying plasma fibrinolytic protein environment, and whether it tracks organ-failure severity, has not been established. Results: This prospective observational study included 283 paired observations in 69 septic patients admitted with a median Acute Physiology and Chronic Health Evaluation III score 81, median SOFA-2 score 13 and a 38% ICU mortality. PAI-1 increased and plasminogen decreased with increasing fibrinolysis resistance (1.77 [1.50-2.09]-fold increase and 0.81 [0.76-0.87]-fold decrease, respectively, per e-fold increase in TPA-LT/FIBA10). Increasing organ-failure severity was also associated with increased PAI-1 and decreased plasminogen (1.23 [1.17-1.29]-fold increase and 0.95 [0.93-0.96]-fold decrease, respectively, per point increase in SOFA-2). In contrast, tissue plasminogen activator activity and absolute a2-antiplasmin did not relate to fibrinolysis resistance or organ failure. Principal component analysis of the fibrinolysis proteins, organ-failure severity and fibrinolysis resistance identified a dominant axis explaining 35% of the variance, on which PAI-1, SOFA-2 and TPA-LT/FIBA10 loaded together in opposition to plasminogen. Unsupervised clustering of the dataset, performed without reference to patient outcomes, separated a fibrinolysis inhibitor- high, substrate-depleted group with 61% mortality compared to 29% in the preserved- fibrinolysis group. During the ICU stay, PAI-1 decreased within 72 hours in survivors but remained unchanged in non-survivors (interaction p<0.001). A trend was observed for plasminogen levels increasing in survivors but remaining static in non-survivors. Conclusions: Changes in key fibrinolysis proteins, organ-failure severity and fibrinolysis resistance measured by viscoelastometry were coupled facets of the response to sepsis dominated by fibrinolysis inhibitor excess and substrate depletion rather than by reduced activator availability. These findings provide biological validation for bedside viscoelastometric quantification of fibrinolysis resistance and support prospective evaluation of substrate-directed profibrinolytic strategies.

medRxiv
University of Colorado Hospital (US), The University of Sydney (AU), University of Wollongong (AU), Discovery Institute (US), Liverpool Hospital (AU), Canberra Hospital (AU), University of Colorado Anschutz Medical Campus (US), Monash University (AU), University of Colorado Denver (US)
National Health and Medical Research Council
Sepsis Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon