Performance of ChatGPT-5 under a minimal binary prompt for detection of distal radius fractures on plain radiographs

BACKGROUND: General-purpose multimodal large language models (LLMs) are being applied to radiology, but their performance under the simplest realistic clinical query (a single binary fracture-or-not prompt) has not been rigorously quantified. We evaluated ChatGPT-5 on this task using a public distal radius dataset. METHODS: In this retrospective diagnostic accuracy study, 396 anteroposterior distal radius radiographs from the Stanford MURA dataset were submitted to ChatGPT-5, each in a fresh temporary chat session. The prompt was: "Is there a fracture in this X-ray? Answer with yes or no." The reference standard was an image-level label assigned by consensus between a senior orthopedic resident and a board-certified orthopedic surgeon; MURA study-level labels were used only to select candidate images. Twenty-six radiographs (6.6%) returned a hedged response and were excluded from the primary analysis, leaving 370; all 26 were added back in three sensitivity analyses. Outcomes were sensitivity, specificity, PPV, NPV, F1, balanced accuracy, and Cohen's kappa, with 95% Wilson confidence intervals and McNemar's test for error asymmetry. RESULTS: = 4.06, p = 0.044). Non-binary responses occurred in 7.6% of fracture-positive and 5.7% of fracture-negative radiographs (p = 0.54); counting all as errors lowered sensitivity to 47.3% (40.2-54.5), and no assumption raised it above 54.9%. Projected to 20% prevalence, PPV was 30.3% and NPV 85.2%. CONCLUSION: Under a minimal binary prompt and without task-specific fine-tuning, ChatGPT-5 missed approximately half of distal radius fractures and fell well below published performance for dedicated CNN-based fracture detectors. Results are specific to this model version, this prompt, this anatomical region, and this dataset; they constrain claims about autonomous, minimal-prompt use rather than the broader potential of engineered LLM-based radiological workflows.

Authors

Institutions

Publication Details

Journal
Emergency Radiology
Published
2026-10-26
DOI
https://doi.org/10.1007/s10140-026-02550-7
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of ChatGPT-5 under a minimal binary prompt for detection of distal radius fractures on plain radiographs

Dror Ronel, Yaniv Keren, Bana Awad
Emergency Radiology
Artificial Intelligence in Healthcare and Education
article

Performance of ChatGPT-5 under a minimal binary prompt for detection of distal radius fractures on plain radiographs

Dror Ronel, Yaniv Keren, Bana Awad
article en

Abstract

BACKGROUND: General-purpose multimodal large language models (LLMs) are being applied to radiology, but their performance under the simplest realistic clinical query (a single binary fracture-or-not prompt) has not been rigorously quantified. We evaluated ChatGPT-5 on this task using a public distal radius dataset. METHODS: In this retrospective diagnostic accuracy study, 396 anteroposterior distal radius radiographs from the Stanford MURA dataset were submitted to ChatGPT-5, each in a fresh temporary chat session. The prompt was: "Is there a fracture in this X-ray? Answer with yes or no." The reference standard was an image-level label assigned by consensus between a senior orthopedic resident and a board-certified orthopedic surgeon; MURA study-level labels were used only to select candidate images. Twenty-six radiographs (6.6%) returned a hedged response and were excluded from the primary analysis, leaving 370; all 26 were added back in three sensitivity analyses. Outcomes were sensitivity, specificity, PPV, NPV, F1, balanced accuracy, and Cohen's kappa, with 95% Wilson confidence intervals and McNemar's test for error asymmetry. RESULTS: = 4.06, p = 0.044). Non-binary responses occurred in 7.6% of fracture-positive and 5.7% of fracture-negative radiographs (p = 0.54); counting all as errors lowered sensitivity to 47.3% (40.2-54.5), and no assumption raised it above 54.9%. Projected to 20% prevalence, PPV was 30.3% and NPV 85.2%. CONCLUSION: Under a minimal binary prompt and without task-specific fine-tuning, ChatGPT-5 missed approximately half of distal radius fractures and fell well below published performance for dedicated CNN-based fracture detectors. Results are specific to this model version, this prompt, this anatomical region, and this dataset; they constrain claims about autonomous, minimal-prompt use rather than the broader potential of engineered LLM-based radiological workflows.

Emergency Radiology
Technion – Israel Institute of Technology (IL), Rambam Health Care Campus (IL), Rappaport Family Institute for Research in the Medical Sciences (IL)
Technion-Israel Institute of Technology
Openalex Percentile: Top 19%
Artificial Intelligence in Healthcare and Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon