Association of MASLD With Atrial Fibrillation Recurrence After Catheter Ablation: A Meta‐Analysis

ABSTRACT Background Atrial fibrillation (AF) recurrence after catheter ablation remains common. Metabolic dysfunction–associated steatotic liver disease (MASLD) is increasingly recognized as a cardiometabolic condition and has been linked to incident AF, but its association with AF recurrence after catheter ablation remains unclear. This meta‐analysis aimed to determine whether MASLD is associated with recurrent AF after catheter ablation Methods We searched PubMed, Web of Science, and Scopus till July 2026 for studies that included adults with AF undergoing catheter ablation and compared the risk of AF recurrence between those with and without MASLD. A random‐effects model was used to synthesize HRs and corresponding 95% CIs. Between‐study variability was evaluated with the I 2 measure, with additional subgroup analyses stratified by AF type and MASLD diagnostic method. Results Six studies comprising 2921 patients (894 with MASLD) were included. MASLD was significantly associated with an increased risk of AF recurrence after ablation (HR 1.91, 95% CI 1.39–2.64; p < 0.001), with substantial heterogeneity ( I 2 = 69.7%). The association remained significant in both paroxysmal (HR 1.78, 95% CI 1.36–2.33) and persistent AF (HR 1.61, 95% CI 1.26–2.05), with no significant subgroup difference ( p = 0.58). Studies using imaging‐based diagnosis of MASLD showed a significant association, whereas the association was not significant when the Fatty Liver Index was used, with no evidence of a difference between diagnostic‐method subgroups ( p = 0.47) Conclusion MASLD is associated with a higher risk of AF recurrence after catheter ablation and may help identify patients at greater risk of recurrence. Further prospective studies are needed to provide a more comprehensive understanding of this association.

Authors

Institutions

Publication Details

Journal
Pacing and Clinical Electrophysiology
Published
2026-10-26
DOI
https://doi.org/10.1111/pace.70470
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Association of MASLD With Atrial Fibrillation Recurrence After Catheter Ablation: A Meta‐Analysis

Maha AbuZarifa, nada abdelmohsen, Mohamed K. Harfoush, Fawaz K Alfahmi et al.
Pacing and Clinical Electrophysiology
Atrial Fibrillation Management and Outcomes
article

Association of MASLD With Atrial Fibrillation Recurrence After Catheter Ablation: A Meta‐Analysis

Maha AbuZarifa, nada abdelmohsen, Mohamed K. Harfoush, Fawaz K Alfahmi, Aimen Amirat, Shehab Aldeen Allahawyah, Ahmed Adel Mohamed, El‐Sayed A. Issa, Heba S. Mrouj, Ahmed Elhadi, Reda Roshdy
article en

Abstract

ABSTRACT Background Atrial fibrillation (AF) recurrence after catheter ablation remains common. Metabolic dysfunction–associated steatotic liver disease (MASLD) is increasingly recognized as a cardiometabolic condition and has been linked to incident AF, but its association with AF recurrence after catheter ablation remains unclear. This meta‐analysis aimed to determine whether MASLD is associated with recurrent AF after catheter ablation Methods We searched PubMed, Web of Science, and Scopus till July 2026 for studies that included adults with AF undergoing catheter ablation and compared the risk of AF recurrence between those with and without MASLD. A random‐effects model was used to synthesize HRs and corresponding 95% CIs. Between‐study variability was evaluated with the I 2 measure, with additional subgroup analyses stratified by AF type and MASLD diagnostic method. Results Six studies comprising 2921 patients (894 with MASLD) were included. MASLD was significantly associated with an increased risk of AF recurrence after ablation (HR 1.91, 95% CI 1.39–2.64; p < 0.001), with substantial heterogeneity ( I 2 = 69.7%). The association remained significant in both paroxysmal (HR 1.78, 95% CI 1.36–2.33) and persistent AF (HR 1.61, 95% CI 1.26–2.05), with no significant subgroup difference ( p = 0.58). Studies using imaging‐based diagnosis of MASLD showed a significant association, whereas the association was not significant when the Fatty Liver Index was used, with no evidence of a difference between diagnostic‐method subgroups ( p = 0.47) Conclusion MASLD is associated with a higher risk of AF recurrence after catheter ablation and may help identify patients at greater risk of recurrence. Further prospective studies are needed to provide a more comprehensive understanding of this association.

Pacing and Clinical Electrophysiology
Damietta University (EG), Jordan University of Science and Technology (JO), Hashemite University (JO), Mansoura University (EG), Taif University (SA), South Valley University (EG), University of Algiers Benyoucef Benkhedda (DZ), Zagazig University (EG), Al-Quds University (PS), Horus University – Egypt (EG), Alexandria University (EG)
Openalex Percentile: Top 12%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon