Joint reconstruction of multi-contrast relaxation-diffusion imaging

Diffusion MRI across multiple gradient directions, b-values and echo times (TEs) provides complementary tissue contrast but requires extensive sampling. Joint k-space and q-space undersampling requires reconstruction that preserves diffusion- and TE-dependent signal variation while exploiting shared anatomical information. Here we introduce DIFFUSE (Diffusion-relaxometry Implicit Field Fitting from Undersampled k-q Space across Echoes), a subject-specific joint k-q-TE image reconstruction framework. It fits a single implicit neural representation (INR) directly to complementary undersampled multi-coil k-space measurements across diffusion encodings and echo times. The INR (a self-supervised neural network) maps spatial location, b-value and TE to baseline b0 signals and spherical harmonic coefficients for directional diffusion-weighted image reconstruction. The measurement-specific forward model incorporates phase, coil sensitivities and motion and eddy current related transforms. We evaluated DIFFUSE using retrospective Human Connectome Project data, controlled motion simulations and in vivo multi-shell and multi-TE acquisitions. At sixfold in-plane acceleration, DIFFUSE reduced normalized mean squared error by 57-73% relative to SENSE across two diffusion shells in the retrospective experiment. In the controlled motion experiment, motion-aware DIFFUSE reduced normalized mean squared error by 66-72% relative to static DIFFUSE. The prospective study demonstrated multi-shell reconstruction at 1.3 mm isotropic resolution with significantly high signal-to-noise ratio (SNR). In a separate multi-TE experiment, a single representation jointly reconstructed all nine contrasts corresponding to 3 b-value/TE combinations. DIFFUSE thus provides a common reconstruction strategy for accelerated protocols spanning multiple diffusion encodings and echo times.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-10-26
DOI
https://doi.org/10.64898/2026.10.21.760608
Primary Topic
Advanced MRI Techniques and Applications
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Joint reconstruction of multi-contrast relaxation-diffusion imaging

William Consagra, Lipeng Ning, Yogesh Rathi A, Kawin Setsompop et al.
bioRxiv (Cold Spring Harbor Laboratory)
Advanced MRI Techniques and Applications
preprint

Joint reconstruction of multi-contrast relaxation-diffusion imaging

William Consagra, Lipeng Ning, Yogesh Rathi A, Kawin Setsompop, Yunqi Wang, Qiang Liu
preprint en

Abstract

Diffusion MRI across multiple gradient directions, b-values and echo times (TEs) provides complementary tissue contrast but requires extensive sampling. Joint k-space and q-space undersampling requires reconstruction that preserves diffusion- and TE-dependent signal variation while exploiting shared anatomical information. Here we introduce DIFFUSE (Diffusion-relaxometry Implicit Field Fitting from Undersampled k-q Space across Echoes), a subject-specific joint k-q-TE image reconstruction framework. It fits a single implicit neural representation (INR) directly to complementary undersampled multi-coil k-space measurements across diffusion encodings and echo times. The INR (a self-supervised neural network) maps spatial location, b-value and TE to baseline b0 signals and spherical harmonic coefficients for directional diffusion-weighted image reconstruction. The measurement-specific forward model incorporates phase, coil sensitivities and motion and eddy current related transforms. We evaluated DIFFUSE using retrospective Human Connectome Project data, controlled motion simulations and in vivo multi-shell and multi-TE acquisitions. At sixfold in-plane acceleration, DIFFUSE reduced normalized mean squared error by 57-73% relative to SENSE across two diffusion shells in the retrospective experiment. In the controlled motion experiment, motion-aware DIFFUSE reduced normalized mean squared error by 66-72% relative to static DIFFUSE. The prospective study demonstrated multi-shell reconstruction at 1.3 mm isotropic resolution with significantly high signal-to-noise ratio (SNR). In a separate multi-TE experiment, a single representation jointly reconstructed all nine contrasts corresponding to 3 b-value/TE combinations. DIFFUSE thus provides a common reconstruction strategy for accelerated protocols spanning multiple diffusion encodings and echo times.

bioRxiv (Cold Spring Harbor Laboratory)
Brigham and Women's Hospital (US), Harvard University (US), University of South Carolina (US), Stanford University (US)
National Institutes of Health, National Institute of Mental Health
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon