Association Between Cilio-Lenticular Distance and Anterior Chamber Depth in Primary Angle-Closure Glaucoma

Purpose: To investigate the lens and ciliary spatial characteristics in primary angle-closure glaucoma (PACG) patients using ocular magnetic resonance imaging (MRI), aiming to elucidate the mechanism underlying PACG pathogenesis. Methods: This is a cross-sectional observational case-control study that used a clinical 3.0T MRI with a specialized coil to acquire binocular images in the axial plane. Quantitative measurements were conducted to obtain anatomical parameters of the lens, ciliary body, and vitreous cavity, including lens equator diameter (LED), cilio-lenticular distance (CLD), ciliary to ciliary distance (CCD), vitreous cavity width, and vitreous cavity depth. Linear mixed effects models were used for statistical analysis. Result: Twenty-five eyes of 13 PACG patients and 19 eyes of 10 healthy participants were enrolled in this study. The PACG group exhibited a statistically significant larger Sectional Area of Lens (33.72 ± 2.50 mm2 vs. 30.72 ± 2.42 mm2, P = 0.005), lower CCD (9.74 ± 0.45 mm vs. 10.41 ± 0.62 mm, P = 0.003), and lower CLD (0.51 ± 0.09 mm vs. 0.85 ± 0.17 mm, P < 0.001). No differences were found in LED and characteristic parameters of vitreous cavities. CLD demonstrated a high predictive performance for PACG (area under the curve [AUC] = 0.979), approaching that of the classical parameter anterior chamber depth (AUC = 0.993), with both showing statistical significance (P < 0.001). Conclusions: A smaller CLD correlates with a shallow anterior chamber and indicates a more crowded ciliary-lens configuration, a crucial indictor of PACG.

Authors

Institutions

Publication Details

Journal
Investigative Ophthalmology & Visual Science
Published
2026-10-26
DOI
https://doi.org/10.1167/iovs.67.12.64
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Association Between Cilio-Lenticular Distance and Anterior Chamber Depth in Primary Angle-Closure Glaucoma

Rongrong Le, Peijuan Wang, 张绍丹, Yanqian Xie et al.
Investigative Ophthalmology & Visual Science
Glaucoma and retinal disorders
article

Association Between Cilio-Lenticular Distance and Anterior Chamber Depth in Primary Angle-Closure Glaucoma

Rongrong Le, Peijuan Wang, 张绍丹, Yanqian Xie, Kun Xiong, Jingjing Zuo, Fengping Zhao, Yongzhen Yu, Changrong Lei, Huiyan Mao, Haishuang Lin, Xuanli Zheng, Xiaojie Wang, Yuanbo Liang, Ying Han, Nikhita Mummaneni
article en

Abstract

Purpose: To investigate the lens and ciliary spatial characteristics in primary angle-closure glaucoma (PACG) patients using ocular magnetic resonance imaging (MRI), aiming to elucidate the mechanism underlying PACG pathogenesis. Methods: This is a cross-sectional observational case-control study that used a clinical 3.0T MRI with a specialized coil to acquire binocular images in the axial plane. Quantitative measurements were conducted to obtain anatomical parameters of the lens, ciliary body, and vitreous cavity, including lens equator diameter (LED), cilio-lenticular distance (CLD), ciliary to ciliary distance (CCD), vitreous cavity width, and vitreous cavity depth. Linear mixed effects models were used for statistical analysis. Result: Twenty-five eyes of 13 PACG patients and 19 eyes of 10 healthy participants were enrolled in this study. The PACG group exhibited a statistically significant larger Sectional Area of Lens (33.72 ± 2.50 mm2 vs. 30.72 ± 2.42 mm2, P = 0.005), lower CCD (9.74 ± 0.45 mm vs. 10.41 ± 0.62 mm, P = 0.003), and lower CLD (0.51 ± 0.09 mm vs. 0.85 ± 0.17 mm, P < 0.001). No differences were found in LED and characteristic parameters of vitreous cavities. CLD demonstrated a high predictive performance for PACG (area under the curve [AUC] = 0.979), approaching that of the classical parameter anterior chamber depth (AUC = 0.993), with both showing statistical significance (P < 0.001). Conclusions: A smaller CLD correlates with a shallow anterior chamber and indicates a more crowded ciliary-lens configuration, a crucial indictor of PACG.

Investigative Ophthalmology & Visual ScienceVol. 67(12)
University of California, San Francisco (US), Wenzhou Medical University (CN), Affiliated Eye Hospital of Wenzhou Medical College (CN), Aier Eye Hospital Group (China) (CN)
Openalex Percentile: Top 9%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon