A Novel High-Performance Non-Enzymatic Electrochemical Glucose Sensor for Aqueous Media Based on MWCNT Modified with Aluminium/Zinc Layered Hydroxide-Ferulate

A novel non-enzymatic electrochemical glucose sensor based on aluminium/zinc layered hydroxide-ferulate (Al/ZLH-FA)-modified multi-walled carbon nanotubes (MWCNTs) was fabricated as a carbon paste electrode.The composite was morphologically characterized by transmission electron microscopy (TEM), while its electrochemical behaviour was evaluated using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and squarewave voltammetry (SWV).Under optimized experimental conditions, the sensor exhibited a linear response to glucose concentrations ranging from 3 to 300 µmol L -1 , with a correlation coefficient (R 2 ) of 0.9984.The limit of detection (LOD) was calculated to be 0.05 µmol L -1 .Transmission electron microscopy (TEM) has been used to determine the morphology of Al/ZLH-FA and Al/ZLH-FA/MWCNT, respectively.Because of its remarkable selectivity and sensitivity, the Al/ZLH-FA/MWCNT composite electrode that was produced was useful for analytical applications.

Publication Details

Journal
Malaysian Journal of Chemistry
Published
2026-10-27
DOI
https://doi.org/10.55373/mjchem.v28i5.99
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel High-Performance Non-Enzymatic Electrochemical Glucose Sensor for Aqueous Media Based on MWCNT Modified with Aluminium/Zinc Layered Hydroxide-Ferulate

Malaysian Journal of Chemistry
Electrochemical sensors and biosensors
article

A Novel High-Performance Non-Enzymatic Electrochemical Glucose Sensor for Aqueous Media Based on MWCNT Modified with Aluminium/Zinc Layered Hydroxide-Ferulate

article en

Abstract

A novel non-enzymatic electrochemical glucose sensor based on aluminium/zinc layered hydroxide-ferulate (Al/ZLH-FA)-modified multi-walled carbon nanotubes (MWCNTs) was fabricated as a carbon paste electrode.The composite was morphologically characterized by transmission electron microscopy (TEM), while its electrochemical behaviour was evaluated using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and squarewave voltammetry (SWV).Under optimized experimental conditions, the sensor exhibited a linear response to glucose concentrations ranging from 3 to 300 µmol L -1 , with a correlation coefficient (R 2 ) of 0.9984.The limit of detection (LOD) was calculated to be 0.05 µmol L -1 .Transmission electron microscopy (TEM) has been used to determine the morphology of Al/ZLH-FA and Al/ZLH-FA/MWCNT, respectively.Because of its remarkable selectivity and sensitivity, the Al/ZLH-FA/MWCNT composite electrode that was produced was useful for analytical applications.

Malaysian Journal of ChemistryVol. 28(5)
Openalex Percentile: Top 25%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
A Novel High-Performance Non-Enzymatic Electrochemical Glucose Sensor for Aqueous Media Based on MWCNT Modified with Aluminium/Zinc Layered Hydroxide-Ferulate · Malaysian Journal of Chemistry (2026) | TGRS Research Map | TGRS