Rapid and sensitive on-chip microcapillary electrophoresis for discrete SARS-CoV-2 immunocomplex diagnostics

Rapid, sensitive, and quantitative molecular diagnostics remain in sustained demand, driving the development of miniaturized analytical platforms. Conventional rapid antigen tests rely on lateral-flow techniques, requiring capture and detection antibodies, gold nanoparticle labels, and precise binding kinetics to generate a visible signal. Microcapillary electrophoresis (µCE) is well established for genomic DNA separation, yet its extension to protein analysis remains limited. Here we report a µCE method for rapid separation and detection of SARS-CoV-2 immunocomplexes, using a polymethyl methacrylate microfluidic chip filled with 5.5% linear polyacrylamide as the sieving matrix to perform an on-chip immunoassay. Unlike lateral-flow formats, our platform requires only a single fluorescently labeled antibody, with a positive or negative result read directly from the presence or absence of an immunocomplex peak. Fluorescently labeled antibodies were incubated with SARS-CoV-2 nucleocapsid protein (Np) to form immunocomplexes, the bound complex was resolved from free antibody within 30 s, based on the difference in electrophoretic mobility caused by altered charge-to-size ratio. Fluorescence signals were acquired by fluorescence microscopy and processed with a custom Python pipeline for electropherogram analysis and peak profiling. The assay resolved Np antigen across the alpha, beta, and delta variants and produced consistent, reproducible signals from clinical oropharyngeal swab specimens, achieving a detection limit of 5 µg/mL with minimal reagent consumption. Specificity was confirmed against a panel of common respiratory pathogens, respiratory syncytial virus, adenovirus, or influenza virus, with no visible immunocomplex peak indicating negligible cross-reactivity. Its sub-minute separation time and compatibility with automation position this µCE platform as a scalable route to decentralized point-of-care testing and screening for infectious diseases.

Authors

Institutions

Publication Details

Journal
Advances in Industrial and Engineering Chemistry
Published
2026-10-26
DOI
https://doi.org/10.1007/s44405-026-00054-z
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid and sensitive on-chip microcapillary electrophoresis for discrete SARS-CoV-2 immunocomplex diagnostics

Gayathri Sureshkumar, To Thanh Truc Truong, Tae Seok Seo, Trung Nghia Tang
Advances in Industrial and Engineering Chemistry
Microfluidic and Capillary Electrophoresis Applications
article

Rapid and sensitive on-chip microcapillary electrophoresis for discrete SARS-CoV-2 immunocomplex diagnostics

Gayathri Sureshkumar, To Thanh Truc Truong, Tae Seok Seo, Trung Nghia Tang
article en

Abstract

Rapid, sensitive, and quantitative molecular diagnostics remain in sustained demand, driving the development of miniaturized analytical platforms. Conventional rapid antigen tests rely on lateral-flow techniques, requiring capture and detection antibodies, gold nanoparticle labels, and precise binding kinetics to generate a visible signal. Microcapillary electrophoresis (µCE) is well established for genomic DNA separation, yet its extension to protein analysis remains limited. Here we report a µCE method for rapid separation and detection of SARS-CoV-2 immunocomplexes, using a polymethyl methacrylate microfluidic chip filled with 5.5% linear polyacrylamide as the sieving matrix to perform an on-chip immunoassay. Unlike lateral-flow formats, our platform requires only a single fluorescently labeled antibody, with a positive or negative result read directly from the presence or absence of an immunocomplex peak. Fluorescently labeled antibodies were incubated with SARS-CoV-2 nucleocapsid protein (Np) to form immunocomplexes, the bound complex was resolved from free antibody within 30 s, based on the difference in electrophoretic mobility caused by altered charge-to-size ratio. Fluorescence signals were acquired by fluorescence microscopy and processed with a custom Python pipeline for electropherogram analysis and peak profiling. The assay resolved Np antigen across the alpha, beta, and delta variants and produced consistent, reproducible signals from clinical oropharyngeal swab specimens, achieving a detection limit of 5 µg/mL with minimal reagent consumption. Specificity was confirmed against a panel of common respiratory pathogens, respiratory syncytial virus, adenovirus, or influenza virus, with no visible immunocomplex peak indicating negligible cross-reactivity. Its sub-minute separation time and compatibility with automation position this µCE platform as a scalable route to decentralized point-of-care testing and screening for infectious diseases.

Advances in Industrial and Engineering ChemistryVol. 2(1)
Kyung Hee University (KR)
Openalex Percentile: Top 25%
Microfluidic and Capillary Electrophoresis Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Rapid and sensitive on-chip microcapillary electrophoresis for discrete SARS-CoV-2 immunocomplex diagnostics — Gayathri Sureshkumar, To Thanh Truc Truong, et al. · Advances in Industrial and Engineering Chemistry (2026) | TGRS Research Map | TGRS