Dual-Microstructure Configuration Design Enabling Highly Sensitive Biotemplated Flexible Capacitive Pressure Sensors

Flexible capacitive pressure sensors (FCPSs) that resolve subtle pressure are central to soft robotics and human health monitoring. Their sensitivity is affected by microstructures incorporated at the interface between the electrode and dielectric layers, but fabricating fine artificial microstructures typically requires costly techniques. Biological templates offer a cost-effective way to form these microstructures, yet biotemplated FCPSs have remained limited in sensitivity. Efforts to improve sensitivity have predominantly focused on microstructure geometries, whereas the microstructure configuration in the sensor has not been well-studied. Here, we establish design insights for microstructure configurations through simplified computational analysis, revealing that amplifying the effective interelectrode distance variation rate and effective permittivity variation rate within the structured region is the key to enhancing overall sensitivity. Following this insight, we propose a dual-microstructure configuration that increases the air fraction within the structured region, leading to the amplified effective permittivity variation rate. Both computational and experimental assessments demonstrate that the dual-microstructure configuration outperforms conventional ones in sensitivity, with the fabricated sensor achieving the highest sensitivity of 4.3 kPa-1 among all the reported biotemplated FCPSs using the same dielectric materials (Table S1), along with a fast response/recovery time of 46/20 ms, a low detection limit of 1.2 Pa, and stable operation over 7500 cycles. These performance attributes enable the sensor for applications in robotic hand tactile sensing for soft objects and real-time physiological signal monitoring. Consequently, the proposed dual-microstructure configuration offers a generalizable pathway to enhance the sensitivity of biotemplated FCPSs, promoting the development of high-performance, cost-effective flexible pressure sensors.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2026-10-26
DOI
https://doi.org/10.1021/acsami.6c13548
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual-Microstructure Configuration Design Enabling Highly Sensitive Biotemplated Flexible Capacitive Pressure Sensors

Sijun Seong, Xiwen Gong, Zachary Pizzo, Carlos A. Figueroa Morales et al.
ACS Applied Materials & Interfaces
Advanced Sensor and Energy Harvesting Materials
article

Dual-Microstructure Configuration Design Enabling Highly Sensitive Biotemplated Flexible Capacitive Pressure Sensors

Sijun Seong, Xiwen Gong, Zachary Pizzo, Carlos A. Figueroa Morales, Zhengtao Hu, Ke Li, Zhuokai Qu, Jierui Zhao, Tony Zheng
article en

Abstract

Flexible capacitive pressure sensors (FCPSs) that resolve subtle pressure are central to soft robotics and human health monitoring. Their sensitivity is affected by microstructures incorporated at the interface between the electrode and dielectric layers, but fabricating fine artificial microstructures typically requires costly techniques. Biological templates offer a cost-effective way to form these microstructures, yet biotemplated FCPSs have remained limited in sensitivity. Efforts to improve sensitivity have predominantly focused on microstructure geometries, whereas the microstructure configuration in the sensor has not been well-studied. Here, we establish design insights for microstructure configurations through simplified computational analysis, revealing that amplifying the effective interelectrode distance variation rate and effective permittivity variation rate within the structured region is the key to enhancing overall sensitivity. Following this insight, we propose a dual-microstructure configuration that increases the air fraction within the structured region, leading to the amplified effective permittivity variation rate. Both computational and experimental assessments demonstrate that the dual-microstructure configuration outperforms conventional ones in sensitivity, with the fabricated sensor achieving the highest sensitivity of 4.3 kPa-1 among all the reported biotemplated FCPSs using the same dielectric materials (Table S1), along with a fast response/recovery time of 46/20 ms, a low detection limit of 1.2 Pa, and stable operation over 7500 cycles. These performance attributes enable the sensor for applications in robotic hand tactile sensing for soft objects and real-time physiological signal monitoring. Consequently, the proposed dual-microstructure configuration offers a generalizable pathway to enhance the sensitivity of biotemplated FCPSs, promoting the development of high-performance, cost-effective flexible pressure sensors.

ACS Applied Materials & Interfaces
University of Michigan (US)
University of Michigan, American Chemical Society Petroleum Research Fund, Horace H. Rackham School of Graduate Studies, University of Michigan
Openalex Percentile: Top 25%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon