Colorectal polyp size measurement comparing biopsy forceps with visual assessment during real-time colonoscopy: A prospective, multicenter, international study
BACKGROUNDColorectal polyp size is important for assigning appropriate surveillance intervals, but conventional visual assessment (VA) often results in size misclassification.The use of a biopsy forceps (BF) might improve polyp size assessment as suggested in current guidelines. AIMTo compare measurement performance of BF-assisted size measurement with VA during real-time colonoscopy. METHODSA prospective, multicenter, international study was conducted at 5 tertiary hospitals.Patients aged ≥ 18 years scheduled for screening, surveillance, or diagnostic colonoscopy were included.Polyps were measured during colonoscopy with VA, BF, and a laser system (reference standard) and then removed and sent for histopathological assessment.The primary outcome was inter-method agreement of BF and VA compared to laserbased size measurement.Secondary outcomes included inter-method agreement between BF and VA and size misclassification.Furthermore, clinical implications were explored. RESULTSAmong 110 patients, 276 polyps were detected, including 138 with successful reference laser-based measurements, of which 137 were analyzed.Moderate agreement was found for BF and VA compared to laser measurements (κ = 0.534 vs 0.514) with wide limits of agreement (± 3 mm), while almost perfect agreement (κ = 0.863) was observed between BF and VA.Both BF and VA underestimated polyp size by -0.16 mm and -0.11 mm, 4 / 32 underestimating around 14%-50% of > 5 mm and ≥ 10 mm polyps and overestimating approximately 2%-11% of ≤ 5 mm and < 10 mm polyps.Around 2% of patients were assigned an incorrect surveillance interval using BF and VA, and when implementing a resect-and-discard strategy, 11% of ≤ 5 mm polyps would have undergone histopathology and 14% of > 5 mm polyps would have been discarded. CONCLUSIONBF-assisted size measurement performs similarly to conventional VA, without improving precision or reducing size misclassification.Thus, BF can unlikely replace VA in routine colonoscopy, nor be recommended in clinical guidelines.
Authors
- Nathaniel A. Cohen (ORCID: https://orcid.org/0000-0001-9252-9208)
- Vincent Rijckborst
- Arjun Dave Koch (ORCID: https://orcid.org/0000-0003-0683-2126)
- Dana Ben‐Ami Shor (ORCID: https://orcid.org/0000-0002-0657-2881)
- Milou L. M. van Riswijk (ORCID: https://orcid.org/0000-0002-0589-685X)
- Omer Goldstein
- Douglas Kevin Rex (ORCID: https://orcid.org/0000-0002-9836-4309)
- Demi Gerritsen (ORCID: https://orcid.org/0009-0002-9037-4665)
- Peter D. Siersema
- Safwat Odeh
- Seth A Gross
Institutions
- Radboud University Nijmegen (NL)
- Tel Aviv Sourasky Medical Center (IL)
- Radboud University Medical Center (NL)
- NYU Langone Health (US)
- Bnai Zion Medical Center (IL)
- Erasmus MC Cancer Institute (NL)
- Indiana University Indianapolis (US)
- Indiana University School of Medicine (US)
Publication Details
- Journal
- World Journal of Gastrointestinal Endoscopy
- Published
- 2026-10-26
- DOI
- https://doi.org/10.4253/wjge.126001
- Primary Topic
- Colorectal Cancer Screening and Detection
- Type
- article
- Field-Weighted Citation Impact
- 0.00