Motion-robust high-resolution 3D-GRASE pseudo-continuous ASL perfusion imaging at 3T

Purpose: High resolution arterial spin labeling (ASL)-based perfusion imaging is desirable for many applications but suffers from low SNR and motion sensitivity due to the necessity for highly segmented readouts. Acquisition and reconstruction strategies were optimized for motion-robust high-resolution pseudo-continuous arterial spin labeling (pCASL) of the brain at 3T using segmented 3D Gradient and Spin Echo (3D-GRASE) at 2.0-mm isotropic resolution. Methods: A high-resolution 3D-GRASE pCASL sequence was implemented at 3T and evaluated with a focus on the interaction between background suppression strength and motion-corrected reconstruction, together with the fat suppression and control-tag subtraction strategies that strong suppression requires. Motion correction was performed using a novel motion-compensated (alignedSENSE-based) reconstruction that simultaneously estimates the motion and image, accounting for contrast changes between tag and control data. Eight healthy volunteers were scanned under motion-free and cued motion conditions. Image quality was assessed against motion-free reference images using peak signal-to-noise ratio (PSNR) and a structural similarity index measure (SSIM). Results: The optimized acquisition-reconstruction pipeline enabled robust 2.0-mm isotropic pCASL at 3T and showed improved resistance to motion-related degradation. Strong BGS provided near-complete suppression of static tissue, and water excitation reduced lipid contamination and improved coil sensitivity estimation. The regularized alignedSENSE motion correction further improved perfusion-image quality, increasing SSIM by 18.7% under Strong BGS. Conclusion: Robust high-resolution pCASL at 3T can be achieved through combined optimization of acquisition and reconstruction. The combination of Strong BGS, water excitation, reference-superimposed processing, and regularized motion correction mitigates motion-related degradation and yields higher-quality perfusion images for high-resolution ASL.

Authors

Institutions

Publication Details

Journal
medRxiv
Published
2026-10-26
DOI
https://doi.org/10.64898/2026.10.23.26366363
Primary Topic
Advanced MRI Techniques and Applications
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Motion-robust high-resolution 3D-GRASE pseudo-continuous ASL perfusion imaging at 3T

Mark Chiew, Minhao Hu, Frederik Lange, Peter Jezzard et al.
medRxiv
Advanced MRI Techniques and Applications
preprint

Motion-robust high-resolution 3D-GRASE pseudo-continuous ASL perfusion imaging at 3T

Mark Chiew, Minhao Hu, Frederik Lange, Peter Jezzard, Thomas W. Okell
preprint en

Abstract

Purpose: High resolution arterial spin labeling (ASL)-based perfusion imaging is desirable for many applications but suffers from low SNR and motion sensitivity due to the necessity for highly segmented readouts. Acquisition and reconstruction strategies were optimized for motion-robust high-resolution pseudo-continuous arterial spin labeling (pCASL) of the brain at 3T using segmented 3D Gradient and Spin Echo (3D-GRASE) at 2.0-mm isotropic resolution. Methods: A high-resolution 3D-GRASE pCASL sequence was implemented at 3T and evaluated with a focus on the interaction between background suppression strength and motion-corrected reconstruction, together with the fat suppression and control-tag subtraction strategies that strong suppression requires. Motion correction was performed using a novel motion-compensated (alignedSENSE-based) reconstruction that simultaneously estimates the motion and image, accounting for contrast changes between tag and control data. Eight healthy volunteers were scanned under motion-free and cued motion conditions. Image quality was assessed against motion-free reference images using peak signal-to-noise ratio (PSNR) and a structural similarity index measure (SSIM). Results: The optimized acquisition-reconstruction pipeline enabled robust 2.0-mm isotropic pCASL at 3T and showed improved resistance to motion-related degradation. Strong BGS provided near-complete suppression of static tissue, and water excitation reduced lipid contamination and improved coil sensitivity estimation. The regularized alignedSENSE motion correction further improved perfusion-image quality, increasing SSIM by 18.7% under Strong BGS. Conclusion: Robust high-resolution pCASL at 3T can be achieved through combined optimization of acquisition and reconstruction. The combination of Strong BGS, water excitation, reference-superimposed processing, and regularized motion correction mitigates motion-related degradation and yields higher-quality perfusion images for high-resolution ASL.

medRxiv
Sunnybrook Health Science Centre (CA), University of Toronto (CA), University of Oxford (GB), Wellcome Centre for Integrative Neuroimaging (GB), Sunnybrook Research Institute (CA)
Wellcome Trust, National Institute for Health and Care Research, Royal Society, University of Oxford, Canada Research Chairs, NIHR Oxford Biomedical Research Centre
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon