Agreement Between ECG-Derived Heart Rate Variability and Finger-PPG Pulse Rate Variability During Rest: A Dual-Sensor Study Using Polar H10 and LifePulsePro

Background. Finger photoplethysmography (PPG) permits brief measurements of pulse rate variability (PRV), although pulse intervals and ECG R–R intervals represent different physiological events. Objective. To assess the agreement of Polar H10 R–R intervals with LifePulsePro finger pulse intervals at rest, examine time-domain HRV/PRV and repeatability, and explore ECG-to-finger pulse arrival time (PAT) and a derived velocity index in relation to age and sex. Methods. Twenty-five three-minute recordings obtained from 13 volunteers during quiet seated rest were evaluated. Five thousand two hundred forty-four accepted ECG–PPG interval pairs were recalculated from the synchronized interval exports. Repeated measurements were averaged within volunteer for inferential analysis. Results. Volunteer-level mean absolute interval error was 5.23 ms (95% CI 4.53–5.93), with mean within-record correlation r=0.965 (95% CI 0.947–0.983) and signed bias +0.010 ms (p=0.760). PPG SDNN and RMSSD exceeded ECG values by 4.73% and 15.22%, respectively. MAE test–retest ICC(3,1) was 0.85. Mean PAT-foot was 182.2 ms and the protocol-specific velocity index vPAT averaged 5.05 m/s (95% CI 4.75–5.34). Eleven of 13 volunteer values were at or below the application’s preliminary age-group medians. Conclusions. Finger PPG preserved beat-to-beat timing closely during quiet rest, but time-domain PRV indices showed measurable positive bias, especially RMSSD. PAT and vPAT can be described with the dual-sensor system; they require independent vascular validation before clinical interpretation.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-10-26
DOI
https://doi.org/10.5281/zenodo.23660056
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Agreement Between ECG-Derived Heart Rate Variability and Finger-PPG Pulse Rate Variability During Rest: A Dual-Sensor Study Using Polar H10 and LifePulsePro

Aydar Safin
Zenodo (CERN European Organization for Nuclear Research)
Non-Invasive Vital Sign Monitoring
preprint

Agreement Between ECG-Derived Heart Rate Variability and Finger-PPG Pulse Rate Variability During Rest: A Dual-Sensor Study Using Polar H10 and LifePulsePro

Aydar Safin
preprint en

Abstract

Background. Finger photoplethysmography (PPG) permits brief measurements of pulse rate variability (PRV), although pulse intervals and ECG R–R intervals represent different physiological events. Objective. To assess the agreement of Polar H10 R–R intervals with LifePulsePro finger pulse intervals at rest, examine time-domain HRV/PRV and repeatability, and explore ECG-to-finger pulse arrival time (PAT) and a derived velocity index in relation to age and sex. Methods. Twenty-five three-minute recordings obtained from 13 volunteers during quiet seated rest were evaluated. Five thousand two hundred forty-four accepted ECG–PPG interval pairs were recalculated from the synchronized interval exports. Repeated measurements were averaged within volunteer for inferential analysis. Results. Volunteer-level mean absolute interval error was 5.23 ms (95% CI 4.53–5.93), with mean within-record correlation r=0.965 (95% CI 0.947–0.983) and signed bias +0.010 ms (p=0.760). PPG SDNN and RMSSD exceeded ECG values by 4.73% and 15.22%, respectively. MAE test–retest ICC(3,1) was 0.85. Mean PAT-foot was 182.2 ms and the protocol-specific velocity index vPAT averaged 5.05 m/s (95% CI 4.75–5.34). Eleven of 13 volunteer values were at or below the application’s preliminary age-group medians. Conclusions. Finger PPG preserved beat-to-beat timing closely during quiet rest, but time-domain PRV indices showed measurable positive bias, especially RMSSD. PAT and vPAT can be described with the dual-sensor system; they require independent vascular validation before clinical interpretation.

Zenodo (CERN European Organization for Nuclear Research)
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Agreement Between ECG-Derived Heart Rate Variability and Finger-PPG Pulse Rate Variability During Rest: A Dual-Sensor Study Using Polar H10 and LifePulsePro — Aydar Safin · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS