Characterization of airway mucus using quantitative MRI: an in vitro proof-of-concept study

Abstract Objectives A characteristic of chronic obstructive pulmonary disease is mucus hypersecretion. In this proof-of-concept study, we aimed to characterize airway mucus using a quantitative ultrashort echo time (UTE) magnetic resonance imaging (MRI) sequence in a controlled in vitro synthetic mucus model to establish a technical foundation for future in vivo studies. Materials and methods UTE double-echo steady-state (UTE-DESS) was performed to acquire the signal from free induction decay-like signal and spin/stimulated echo-like signal echoes; quantitative MRI parameters (T1, T2, and diffusivity) were estimated. Synthetic mucus phantoms were prepared using mucin (0.20%, 0.50%, and 1.0%) mixed with xanthan gum (0.10%, 0.25%, and 0.50%) to replicate the viscoelastic properties of human laryngeal mucus, and samples were embedded in 1% agar for imaging. Results The mucus phantoms with varying concentrations of mucin and xanthan exhibited visual differences in color and opacity. Estimated T1 values were 2.23 ± 0.16, 2.37 ± 0.20, and 2.09 ± 0.18 s (mean ± standard deviation) for the three tubes with relative mucus concentrations of 1, 2.5, and 5, respectively. Corresponding T2 values were 806.6 ± 105.6, 687.4 ± 78.0, and 475.0 ± 41.3 ms, while diffusivity values were 2.36 ± 0.14, 2.31 ± 0.18, and 2.33 ± 0.18 µm 2 /ms for the three tubes. Only the T2 relaxation times showed a significant linear correlation with mucus concentration ( r = -0.9998, p = 0.0112). Conclusion UTE-DESS MRI could be feasible for characterizing airway mucus. T2 relaxation time showed a strong inverse correlation with increasing mucus concentration, indicating its sensitivity to mucus content. Key Points Question Can a novel quantitative ultrashort echo time MRI sequence noninvasively characterize airway mucus properties and overcome conventional lung imaging limitations in muco-obstructive diseases? Findings In this controlled in vitro model, UTE-DESS MRI mapping demonstrated that T2 relaxation times alone showed a strong inverse correlation with increasing mucus concentrations. Relevance statement This exploratory proof-of-concept establishes a technical foundation for radiation-free, noninvasive T2 mapping to monitor and phenotype chronic obstructive pulmonary disease and other mucoobstructive lung diseases in future in vivo studies.

Authors

Institutions

Publication Details

Journal
European Radiology Experimental
Published
2026-10-26
DOI
https://doi.org/10.1186/s41747-026-00842-8
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization of airway mucus using quantitative MRI: an in vitro proof-of-concept study

Hyungseok Jang, Ahmadreza Ghasemiesfe, Sam Sedaghat, Misagh Piran et al.
European Radiology Experimental
Advanced MRI Techniques and Applications
article

Characterization of airway mucus using quantitative MRI: an in vitro proof-of-concept study

Hyungseok Jang, Ahmadreza Ghasemiesfe, Sam Sedaghat, Misagh Piran, Eddie Fu, Youngkyoo Jung, Jin Il Park
article en

Abstract

Abstract Objectives A characteristic of chronic obstructive pulmonary disease is mucus hypersecretion. In this proof-of-concept study, we aimed to characterize airway mucus using a quantitative ultrashort echo time (UTE) magnetic resonance imaging (MRI) sequence in a controlled in vitro synthetic mucus model to establish a technical foundation for future in vivo studies. Materials and methods UTE double-echo steady-state (UTE-DESS) was performed to acquire the signal from free induction decay-like signal and spin/stimulated echo-like signal echoes; quantitative MRI parameters (T1, T2, and diffusivity) were estimated. Synthetic mucus phantoms were prepared using mucin (0.20%, 0.50%, and 1.0%) mixed with xanthan gum (0.10%, 0.25%, and 0.50%) to replicate the viscoelastic properties of human laryngeal mucus, and samples were embedded in 1% agar for imaging. Results The mucus phantoms with varying concentrations of mucin and xanthan exhibited visual differences in color and opacity. Estimated T1 values were 2.23 ± 0.16, 2.37 ± 0.20, and 2.09 ± 0.18 s (mean ± standard deviation) for the three tubes with relative mucus concentrations of 1, 2.5, and 5, respectively. Corresponding T2 values were 806.6 ± 105.6, 687.4 ± 78.0, and 475.0 ± 41.3 ms, while diffusivity values were 2.36 ± 0.14, 2.31 ± 0.18, and 2.33 ± 0.18 µm 2 /ms for the three tubes. Only the T2 relaxation times showed a significant linear correlation with mucus concentration ( r = -0.9998, p = 0.0112). Conclusion UTE-DESS MRI could be feasible for characterizing airway mucus. T2 relaxation time showed a strong inverse correlation with increasing mucus concentration, indicating its sensitivity to mucus content. Key Points Question Can a novel quantitative ultrashort echo time MRI sequence noninvasively characterize airway mucus properties and overcome conventional lung imaging limitations in muco-obstructive diseases? Findings In this controlled in vitro model, UTE-DESS MRI mapping demonstrated that T2 relaxation times alone showed a strong inverse correlation with increasing mucus concentrations. Relevance statement This exploratory proof-of-concept establishes a technical foundation for radiation-free, noninvasive T2 mapping to monitor and phenotype chronic obstructive pulmonary disease and other mucoobstructive lung diseases in future in vivo studies.

European Radiology ExperimentalVol. 10(1)
University Hospital Heidelberg (DE), University of California, Davis (US)
Openalex Percentile: Top 13%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon