Disposable Screen-Printed Ca2+ Sensor Using NH2-MIL-125@rGO as Solid-Contact Layer for Raw Milk Analysis

Solid-contact ion-selective electrodes have been extensively utilized for calcium ion detection, particularly in applications involving milk samples. In this study, a solid-contact was developed using a composite material of Ti8O8(OH)4(H2bdc-NH2)6 (NH2-MIL-125) and reduced graphene oxide (rGO) to prepare calcium SC-ISE (NH2-MIL-125@rGO/Ca2+-ISE). The NH2-MIL-125@rGO/Ca2+-ISE demonstrated high double-layer capacitance (222 μF) and rapid electron transfer capabilities. Within the calcium ion concentration range of 10−7~10−1 M, the electrode exhibited an excellent Nernstian response, with a rapid response time (2~3 s) and a low detection limit of 10−7.2 M. Additionally, the electrode performed exceptionally in water layer and anti-interference tests, showing enhanced potential stability and response speed while being unaffected by environmental factors such as light, CO2, and O2. These results confirm the superior performance of the NH2-MIL-125@rGO composite as a solid-contact layer, therefore constructed disposable screen-printed calcium potentiometric sensor. In particular, it demonstrated the capability for rapid and accurate analysis of calcium content in untreated milk samples, highlighting the significant practical potential for development of calibration-free SC-ISEs.

Authors

Institutions

Publication Details

Journal
eChem
Published
2026-10-26
DOI
https://doi.org/10.53941/echem.2026.100012
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Disposable Screen-Printed Ca2+ Sensor Using NH2-MIL-125@rGO as Solid-Contact Layer for Raw Milk Analysis

Qingbo An, Jing Sun, Yunrui Fang, Wanting Zhang et al.
3 links
eChem
Analytical Chemistry and Sensors
article

Disposable Screen-Printed Ca2+ Sensor Using NH2-MIL-125@rGO as Solid-Contact Layer for Raw Milk Analysis

Qingbo An, Jing Sun, Yunrui Fang, Wanting Zhang, Bin Cai, Zhongqian Song, Li Niu
article en

Abstract

Solid-contact ion-selective electrodes have been extensively utilized for calcium ion detection, particularly in applications involving milk samples. In this study, a solid-contact was developed using a composite material of Ti8O8(OH)4(H2bdc-NH2)6 (NH2-MIL-125) and reduced graphene oxide (rGO) to prepare calcium SC-ISE (NH2-MIL-125@rGO/Ca2+-ISE). The NH2-MIL-125@rGO/Ca2+-ISE demonstrated high double-layer capacitance (222 μF) and rapid electron transfer capabilities. Within the calcium ion concentration range of 10−7~10−1 M, the electrode exhibited an excellent Nernstian response, with a rapid response time (2~3 s) and a low detection limit of 10−7.2 M. Additionally, the electrode performed exceptionally in water layer and anti-interference tests, showing enhanced potential stability and response speed while being unaffected by environmental factors such as light, CO2, and O2. These results confirm the superior performance of the NH2-MIL-125@rGO composite as a solid-contact layer, therefore constructed disposable screen-printed calcium potentiometric sensor. In particular, it demonstrated the capability for rapid and accurate analysis of calcium content in untreated milk samples, highlighting the significant practical potential for development of calibration-free SC-ISEs.

eChemVol. 2(2)
Changchun University of Science and Technology (CN), Shandong University (CN), Sun Yat-sen University (CN), Shandong First Medical University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 26%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Disposable Screen-Printed Ca2+ Sensor Using NH2-MIL-125@rGO as Solid-Contact Layer for Raw Milk Analysis — Qingbo An, Jing Sun, et al. · eChem (2026) | TGRS Research Map | TGRS