T2 mapping of individual fascicles of the sciatic nerve at 7 T using multi-echo spin–echo
Abstract Objective Neuropathies can selectively affect individual fascicles within peripheral nerves, but diagnosis is limited by MRI spatial resolution and signal-to-noise ratio. This feasibility study aimed to leverage 7 T MRI to measure sub-millimetric T 2 maps of sciatic nerve fascicles in healthy subjects. Materials and methods Accelerated multi-echo spin–echo sequences were acquired in six healthy volunteers at 7 T. Acceleration included generalised autocalibrating partially parallel acquisition (GRAPPA) and GRAPPATINI, which integrates GRAPPA with model-based accelerated relaxometry. Extended phase graph (EPG) modelling of signal decay was used to compute T 2 maps. Quantitative maps were visually assessed and T 2 values were extracted from regions of interest. Results High-resolution imaging (0.4×0.4x3.0 mm 3 ) enabled visualisation of individual fascicles. T 2 values were lower in fascicles (57.0 ms) than in the non-fascicular intraneural compartment (76.2 ms) and intermuscular fat (132.7 ms). Compared with GRAPPA alone, GRAPPATINI reduced acquisition time (11:05 to 3:35 min) while maintaining fascicle depiction and T 2 consistency (mean difference: 1.45 ms). Overlaying T 2 on S 0 maps enhanced fascicle delineation, facilitating anatomical interpretation. Discussion This approach demonstrated the feasibility of high-resolution T 2 mapping of peripheral nerve fascicles at 7 T, offering a potential tool for improved assessment of nerve microstructure and early neuropathy detection.
Authors
- Tom Hilbert (ORCID: https://orcid.org/0000-0001-8207-4908)
- Dimitrios C. Karampinos (ORCID: https://orcid.org/0000-0003-4922-3662)
- Agustina M. Lascano (ORCID: https://orcid.org/0000-0001-7572-8811)
- Gian Franco Piredda (ORCID: https://orcid.org/0000-0002-8449-6634)
- Frédéric Grouiller (ORCID: https://orcid.org/0000-0003-3445-5831)
- Emilie Sleight (ORCID: https://orcid.org/0000-0003-0034-4578)
- Johann M. E. Jende (ORCID: https://orcid.org/0000-0002-1387-9304)
- Ludovica Romanin (ORCID: https://orcid.org/0000-0001-5031-3302)
- Karl-Olof Lovblad
- Felix T. Kurz
- Karim Gariani
- Laura Gui
Institutions
- University of Geneva (CH)
- German Cancer Research Center (DE)
- Centre Hospitalier Universitaire Vaudois (CH)
- University Hospital of Geneva (CH)
- Centre d'Imagerie BioMedicale (CH)
- École Polytechnique Fédérale de Lausanne (CH)
- Geneva College (US)
- University of Lausanne (CH)
Publication Details
- Journal
- Magnetic Resonance Materials in Physics Biology and Medicine
- Published
- 2026-10-26
- DOI
- https://doi.org/10.1007/s10334-026-01430-y
- Primary Topic
- Advanced MRI Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- École Polytechnique Fédérale de Lausanne
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
- Centre d'Imagerie BioMédicale
- Siemens Healthineers