Guide-sheath-assisted bailout technique for intra-procedural single-leaflet device attachment using the PASCAL system: a case report

Abstract Background Single-leaflet device attachment(SLDA)is a rare but serious complication of mitral valve transcatheter edge-to-edge repair(MTEER). When SLDA occurs after full device release, management options are limited. In contrast, intra-procedural SLDA recognized before full implant release may allow a specific bailout strategy. Case summary A 77-year-old man with severe degenerative mitral regurgitation (MR) underwent MTEER using the PASCAL Ace system because of high surgical risk. Initial device implantation reduced MR from severe to mild. However, after removal of both clasp lines during the release process, SLDA occurred at the posterior leaflet, resulting in recurrent severe MR. Although standard retrieval was no longer feasible, the implant remained connected to the steerable catheter. Under fluoroscopic and transesophageal echocardiographic guidance, a guide sheath was advanced coaxially toward the implant. Controlled insertion of the guide sheath between the clasp and paddle, followed by gradual paddle opening, enabled leaflet disengagement and successful device retrieval without leaflet injury. A second implantation achieved a sufficient reduction in mitral regurgitation. Discussion This case demonstrates a novel bailout technique for intra-procedural SLDA. Successful retrieval requires precise coaxial device alignment, careful catheter manipulation, continuous monitoring of leaflet tension, and meticulous guidance using fluoroscopy and transesophageal echocardiography (TEE). Importantly, prompt recognition of SLDA by TEE is a prerequisite of this technique. In conclusion, the guide-sheath-assisted retrieval technique can represent a potential bailout strategy for intra-procedural SLDA before full implant release during MTEER.

Authors

Institutions

Publication Details

Journal
European Heart Journal - Case Reports
Published
2026-10-24
DOI
https://doi.org/10.1093/ehjcr/ytag800
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Guide-sheath-assisted bailout technique for intra-procedural single-leaflet device attachment using the PASCAL system: a case report

Kazuya Kawai, Yoko Nakaoka, Yuki Nishimura, Hiroki Sugane et al.
European Heart Journal - Case Reports
Cardiac Valve Diseases and Treatments
article

Guide-sheath-assisted bailout technique for intra-procedural single-leaflet device attachment using the PASCAL system: a case report

Kazuya Kawai, Yoko Nakaoka, Yuki Nishimura, Hiroki Sugane, M Nukariya
article en

Abstract

Abstract Background Single-leaflet device attachment(SLDA)is a rare but serious complication of mitral valve transcatheter edge-to-edge repair(MTEER). When SLDA occurs after full device release, management options are limited. In contrast, intra-procedural SLDA recognized before full implant release may allow a specific bailout strategy. Case summary A 77-year-old man with severe degenerative mitral regurgitation (MR) underwent MTEER using the PASCAL Ace system because of high surgical risk. Initial device implantation reduced MR from severe to mild. However, after removal of both clasp lines during the release process, SLDA occurred at the posterior leaflet, resulting in recurrent severe MR. Although standard retrieval was no longer feasible, the implant remained connected to the steerable catheter. Under fluoroscopic and transesophageal echocardiographic guidance, a guide sheath was advanced coaxially toward the implant. Controlled insertion of the guide sheath between the clasp and paddle, followed by gradual paddle opening, enabled leaflet disengagement and successful device retrieval without leaflet injury. A second implantation achieved a sufficient reduction in mitral regurgitation. Discussion This case demonstrates a novel bailout technique for intra-procedural SLDA. Successful retrieval requires precise coaxial device alignment, careful catheter manipulation, continuous monitoring of leaflet tension, and meticulous guidance using fluoroscopy and transesophageal echocardiography (TEE). Importantly, prompt recognition of SLDA by TEE is a prerequisite of this technique. In conclusion, the guide-sheath-assisted retrieval technique can represent a potential bailout strategy for intra-procedural SLDA before full implant release during MTEER.

European Heart Journal - Case Reports
Chikamori Hospital (JP)
Openalex Percentile: Top 12%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon