Mechanistic Understanding of Tissue-Plane Adaptability in Cohesive Polydensified Matrix Hyaluronic Acid Gels Intense and Volume

BACKGROUND Hyaluronic acid (HA) gel behavior depends on material properties, injection technique, implantation depth, and tissue biomechanics. Despite similar HA concentrations and overlapping clinical indications, cohesive polydensified matrix (CPM) gels CPM-I and CPM-V exhibit distinct tissue-plane–dependent projection profiles. OBJECTIVE The aim of this study was to determine whether differences in tissue-plane adaptability between CPM-I and CPM-V are explained by differences in their mechanical behavior under clinically relevant loading conditions. MATERIALS AND METHODS Standardized 100-μL injections of CPM-I and CPM-V were performed in a synthetic tissue model at subdermal and deep implantation depths. Bolus morphology was quantified by 3-dimensional morphometric analysis. Material behavior was characterized using linear and nonlinear oscillatory rheology, compression testing, and extrusion force measurements. RESULTS CPM-I demonstrated greater depth-dependent changes than CPM-V. Deep implantation reduced projection height and bolus volume by 12% and 11% for CPM-I versus 6% and 2% for CPM-V. CPM-I also exhibited greater lateral spread, greater strain to flow, and approximately two-fold higher extrusion force, whereas CPM-V demonstrated greater elastic stiffness. Compression end points were similar. CONCLUSION Despite similar HA concentrations, CPM-I and CPM-V exhibit distinct mechanical and morphometric behaviors. Differences under nonlinear deformation and pressure-driven flow suggest that manufacturing-derived polymer architecture influences tissue-plane adaptability and may support filler selection according to tissue biomechanics.

Authors

Institutions

Publication Details

Journal
Dermatologic Surgery
Published
2026-10-22
DOI
https://doi.org/10.1097/dss.0000000000005395
Primary Topic
Facial Rejuvenation and Surgery Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanistic Understanding of Tissue-Plane Adaptability in Cohesive Polydensified Matrix Hyaluronic Acid Gels Intense and Volume

Ardalan Minokadeh, Pia Katharina Vestweber, Brian S. Biesman, Mimi R. Borrelli et al.
Dermatologic Surgery
Facial Rejuvenation and Surgery Techniques
article

Mechanistic Understanding of Tissue-Plane Adaptability in Cohesive Polydensified Matrix Hyaluronic Acid Gels Intense and Volume

Ardalan Minokadeh, Pia Katharina Vestweber, Brian S. Biesman, Mimi R. Borrelli, Dalvi Humzah, Seda Kazarian, Colin Drabe, Gabriela Casabona
article en

Abstract

BACKGROUND Hyaluronic acid (HA) gel behavior depends on material properties, injection technique, implantation depth, and tissue biomechanics. Despite similar HA concentrations and overlapping clinical indications, cohesive polydensified matrix (CPM) gels CPM-I and CPM-V exhibit distinct tissue-plane–dependent projection profiles. OBJECTIVE The aim of this study was to determine whether differences in tissue-plane adaptability between CPM-I and CPM-V are explained by differences in their mechanical behavior under clinically relevant loading conditions. MATERIALS AND METHODS Standardized 100-μL injections of CPM-I and CPM-V were performed in a synthetic tissue model at subdermal and deep implantation depths. Bolus morphology was quantified by 3-dimensional morphometric analysis. Material behavior was characterized using linear and nonlinear oscillatory rheology, compression testing, and extrusion force measurements. RESULTS CPM-I demonstrated greater depth-dependent changes than CPM-V. Deep implantation reduced projection height and bolus volume by 12% and 11% for CPM-I versus 6% and 2% for CPM-V. CPM-I also exhibited greater lateral spread, greater strain to flow, and approximately two-fold higher extrusion force, whereas CPM-V demonstrated greater elastic stiffness. Compression end points were similar. CONCLUSION Despite similar HA concentrations, CPM-I and CPM-V exhibit distinct mechanical and morphometric behaviors. Differences under nonlinear deformation and pressure-driven flow suggest that manufacturing-derived polymer architecture influences tissue-plane adaptability and may support filler selection according to tissue biomechanics.

Dermatologic Surgery
Merz (United States) (US), Merz (Germany) (DE), Skin Care and Laser Physicians of Beverly Hills (US), Princess of Wales Community Hospital (GB)
Openalex Percentile: Top 10%
Facial Rejuvenation and Surgery Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon