The Screening–Confirmation Gap in Corrosion Under Insulation Inspection: A Critical Review of NDT Evidence, Field Limitations and Asset Integrity Decision Support

Corrosion under insulation (CUI) remains a major asset integrity concern in process plants because degradation occurs beneath insulation, cladding, coatings, or protective wrapping, where direct visual access to the metal surface is restricted. A wide range of non-destructive testing (NDT) and monitoring methods have been used to manage CUI; however, these methods generate different levels of engineering evidence. Moisture detection, thermography, and sensor-based monitoring may indicate corrosion-favorable conditions or activity, whereas pulsed eddy current testing (PEC), guided wave testing (GWT), and radiography can support through-insulation screening of suspicious areas. In contrast, ultrasonic thickness measurement (UTM) and phased-array ultrasonic testing (PAUT)-based corrosion mapping are more appropriately positioned as local confirmation methods after access or inspection windows are created. This review examines the screening-confirmation gap in CUI inspection by classifying inspection and monitoring methods based on the evidence type and decision-support value. This review proposes an evidence-chain framework that links risk indication, screening indication, activity monitoring, local confirmation, and asset integrity decision support. This framework shows why screening and monitoring outputs are valuable for prioritization but should not be overclaimed as final evidence for repair planning, remaining life assessment, risk-based inspection (RBI) updates, or fitness-for-service (FFS) decisions. By distinguishing between indirect risk indicators, suspicious wall-loss responses, active-source evidence, and local confirmation data, this review provides a more defensible basis for integrating NDT results into CUI inspection planning and asset integrity management.

Authors

Institutions

Publication Details

Journal
Corrosion and Materials Degradation
Published
2026-10-22
DOI
https://doi.org/10.3390/cmd7040070
Primary Topic
Structural Integrity and Reliability Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Screening–Confirmation Gap in Corrosion Under Insulation Inspection: A Critical Review of NDT Evidence, Field Limitations and Asset Integrity Decision Support

Jan Lean Tai, Mohammad Sohel
Corrosion and Materials Degradation
Structural Integrity and Reliability Analysis
article

The Screening–Confirmation Gap in Corrosion Under Insulation Inspection: A Critical Review of NDT Evidence, Field Limitations and Asset Integrity Decision Support

Jan Lean Tai, Mohammad Sohel
article en

Abstract

Corrosion under insulation (CUI) remains a major asset integrity concern in process plants because degradation occurs beneath insulation, cladding, coatings, or protective wrapping, where direct visual access to the metal surface is restricted. A wide range of non-destructive testing (NDT) and monitoring methods have been used to manage CUI; however, these methods generate different levels of engineering evidence. Moisture detection, thermography, and sensor-based monitoring may indicate corrosion-favorable conditions or activity, whereas pulsed eddy current testing (PEC), guided wave testing (GWT), and radiography can support through-insulation screening of suspicious areas. In contrast, ultrasonic thickness measurement (UTM) and phased-array ultrasonic testing (PAUT)-based corrosion mapping are more appropriately positioned as local confirmation methods after access or inspection windows are created. This review examines the screening-confirmation gap in CUI inspection by classifying inspection and monitoring methods based on the evidence type and decision-support value. This review proposes an evidence-chain framework that links risk indication, screening indication, activity monitoring, local confirmation, and asset integrity decision support. This framework shows why screening and monitoring outputs are valuable for prioritization but should not be overclaimed as final evidence for repair planning, remaining life assessment, risk-based inspection (RBI) updates, or fitness-for-service (FFS) decisions. By distinguishing between indirect risk indicators, suspicious wall-loss responses, active-source evidence, and local confirmation data, this review provides a more defensible basis for integrating NDT results into CUI inspection planning and asset integrity management.

Corrosion and Materials DegradationVol. 7(4)
Universiti Putra Malaysia (MY)
Openalex Percentile: Top 22%
Structural Integrity and Reliability Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon