Comparative evaluation of long-term corona- and environmentally-aged high-temperature vulcanized silicone rubber nano-composites

This study presents an aging evaluation of high-temperature vulcanized silicone rubber nanocomposites subjected to corona-induced deterioration over different durations, as well as their retardation through the incorporation of nanosized fillers to improve high-voltage insulation performance. In addition to performing corona aging using a multi-needle electrode test system for 72, 172, and 272 h, the test samples were aged in a specially constructed chamber for 5040 h under AC voltage and different environmental stresses, including temperature, humidity, ultraviolet radiation, and acidic and salt fog. Following these different aging treatments (corona/environmental stress), diagnosis based on surface partial discharge and volume/surface current was performed to determine modifications in the electrical properties of the materials under investigation. As a result, the deterioration of the tested samples’ surface properties was indicated by an increase in the mean partial discharge magnitude. Furthermore, a significant change in surface conductivity was noticed at high ambient temperature and test voltage. The results showed that under the given experimental arrangement, corona discharge for about 272 h is adequate to cause considerable degradation of the material properties. Overall, the sample containing 5 wt% of boron nitride demonstrated consistent performance under all investigated conditions, leading to improved aging resistance against different stresses.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-10-22
DOI
https://doi.org/10.1038/s41598-026-76698-0
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative evaluation of long-term corona- and environmentally-aged high-temperature vulcanized silicone rubber nano-composites

Ali Ahmed Salem, Muhammad Zaheer Saleem, Abdulrahman Ahmed Ghaleb Amer, Zulkarnain Ahmad Noorden
Scientific Reports
High voltage insulation and dielectric phenomena
article

Comparative evaluation of long-term corona- and environmentally-aged high-temperature vulcanized silicone rubber nano-composites

Ali Ahmed Salem, Muhammad Zaheer Saleem, Abdulrahman Ahmed Ghaleb Amer, Zulkarnain Ahmad Noorden
article en

Abstract

This study presents an aging evaluation of high-temperature vulcanized silicone rubber nanocomposites subjected to corona-induced deterioration over different durations, as well as their retardation through the incorporation of nanosized fillers to improve high-voltage insulation performance. In addition to performing corona aging using a multi-needle electrode test system for 72, 172, and 272 h, the test samples were aged in a specially constructed chamber for 5040 h under AC voltage and different environmental stresses, including temperature, humidity, ultraviolet radiation, and acidic and salt fog. Following these different aging treatments (corona/environmental stress), diagnosis based on surface partial discharge and volume/surface current was performed to determine modifications in the electrical properties of the materials under investigation. As a result, the deterioration of the tested samples’ surface properties was indicated by an increase in the mean partial discharge magnitude. Furthermore, a significant change in surface conductivity was noticed at high ambient temperature and test voltage. The results showed that under the given experimental arrangement, corona discharge for about 272 h is adequate to cause considerable degradation of the material properties. Overall, the sample containing 5 wt% of boron nitride demonstrated consistent performance under all investigated conditions, leading to improved aging resistance against different stresses.

Scientific Reports
Universiti Putra Malaysia (MY), King Fahd University of Petroleum and Minerals (SA), Sana'a University (YE), University of Technology Malaysia (MY), Ghulam Ishaq Khan Institute of Engineering Sciences and Technology (PK)
Openalex Percentile: Top 28%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon