PFAS Leaching from Common Sampling Materials Using a Standardized Protocol

Abstract Accurate measurement of per‐ and polyfluoroalkyl substances (PFAS) in environmental samples requires minimizing external contamination sources, yet the sampling items themselves can introduce PFAS. Existing sampling guidance often relies on precautionary assumptions rather than empirical data, and prior studies have lacked standardized leaching protocols, limiting interstudy comparability. This study evaluated PFAS leaching from 24 items commonly used for collecting environmental samples and five groundwater pumps under controlled conditions using a modified EPA Method 1313 leaching procedure. Leachate samples were analyzed for an expanded suite of 70 PFAS using LC–MS/MS based on EPA Method 1633. Overall, 37 of the 70 target PFAS were detected at least once in the leachates. Materials with the greatest likelihood of direct sample contact had the lowest overall PFAS leachate concentrations, suggesting limited risk of significant sample contamination under typical field conditions. Testing of the leachate from low‐density polyethylene (LDPE) and high‐density polyethylene (HDPE), and silicone tubing, bailers, and bladders resulted in some of the lowest analyte detections. In contrast, pronounced compound‐ and material‐specific results were observed for a specific nylon braided rope, polytetrafluoroethylene (PTFE) tubing, and PTFE bladders, all of which yielded the highest PFAS concentrations and the broadest analyte profiles in leachate. Evaluation of sampling pumps yielded scattered detections without consistent differentiation. This work may be used as a basis for future researchers to evaluate equipment and materials that may contribute PFAS to environmental samples.

Authors

Publication Details

Journal
Groundwater Monitoring & Remediation
Published
2026-10-22
DOI
https://doi.org/10.1111/gwmr.70089
Primary Topic
Per- and polyfluoroalkyl substances research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PFAS Leaching from Common Sampling Materials Using a Standardized Protocol

Taryn McKnight, Alana Cohen, Jim Fenstermacher, Charles Neslund
Groundwater Monitoring & Remediation
Per- and polyfluoroalkyl substances research
article

PFAS Leaching from Common Sampling Materials Using a Standardized Protocol

Taryn McKnight, Alana Cohen, Jim Fenstermacher, Charles Neslund
article en

Abstract

Abstract Accurate measurement of per‐ and polyfluoroalkyl substances (PFAS) in environmental samples requires minimizing external contamination sources, yet the sampling items themselves can introduce PFAS. Existing sampling guidance often relies on precautionary assumptions rather than empirical data, and prior studies have lacked standardized leaching protocols, limiting interstudy comparability. This study evaluated PFAS leaching from 24 items commonly used for collecting environmental samples and five groundwater pumps under controlled conditions using a modified EPA Method 1313 leaching procedure. Leachate samples were analyzed for an expanded suite of 70 PFAS using LC–MS/MS based on EPA Method 1633. Overall, 37 of the 70 target PFAS were detected at least once in the leachates. Materials with the greatest likelihood of direct sample contact had the lowest overall PFAS leachate concentrations, suggesting limited risk of significant sample contamination under typical field conditions. Testing of the leachate from low‐density polyethylene (LDPE) and high‐density polyethylene (HDPE), and silicone tubing, bailers, and bladders resulted in some of the lowest analyte detections. In contrast, pronounced compound‐ and material‐specific results were observed for a specific nylon braided rope, polytetrafluoroethylene (PTFE) tubing, and PTFE bladders, all of which yielded the highest PFAS concentrations and the broadest analyte profiles in leachate. Evaluation of sampling pumps yielded scattered detections without consistent differentiation. This work may be used as a basis for future researchers to evaluate equipment and materials that may contribute PFAS to environmental samples.

Groundwater Monitoring & Remediation
Openalex Percentile: Top 23%
Per- and polyfluoroalkyl substances research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
PFAS Leaching from Common Sampling Materials Using a Standardized Protocol — Taryn McKnight, Alana Cohen, et al. · Groundwater Monitoring & Remediation (2026) | TGRS Research Map | TGRS