Poly(indole-5-carboxylic acid) Synthesized by Acid-Assisted Polymerization as an Innovative Material for Detecting Cationic Surfactants and Heavy-Metal Ions

Abstract Poly(indole-5-carboxylic acid) [poly(IN5CA)] was prepared by acid-assisted oxidative polymerization of the indole-5-carboxylic acid monomer in concentrated formic acid, using ammonium peroxodisulfate as the oxidant, at three monomer-to-oxidant ratios, and evaluated as a proof-of-concept sensing platform. MALDI-TOF mass spectrometry showed a dominant peak consistent with a cyclic trimer, together with a minor series of higher-mass peaks spaced at single monomer-unit intervals, indicating that a small fraction of the material extends as linear oligomers. Raman and ATR-FTIR spectroscopy confirmed oxidized conjugated segments. At the highest oxidant loading (1:1), ATR-FTIR revealed strong carboxylate (COO–) bands indicative of an additional, oxidant-induced transformation of the carboxylic acid groups; the intermediate 2:1 ratio was therefore selected, as it yielded oxidized conjugated oligomers without this transformation. X-ray diffraction showed the material to be predominantly amorphous, with a minor crystalline component attributed to a residual sulfate-based salt derived from the oxidant. The selected formulation remained stable within its UV–vis spectral envelope over 21 days, while fluorescence intensity showed a modest, nonmonotonic variation over the same period. Poly(IN5CA), immobilized as a drop-cast film on glassy-carbon electrodes, showed a concentration-dependent potentiometric response to the cationic surfactants CTAB and CHX, attributed to neutralization of the film’s negative surface charge. The CTAB slope (−21.2 mV/decade) was markedly sub-Nernstian for a monovalent cation, whereas the CHX slope (−29.2 mV/decade) closely approached the theoretical value expected for an effectively divalent cation. A potentiometric response to the heavy metal ions tested was not reproducible under the present conditions. In solution, the free polymer showed a fluorometric response to both surfactants and to Pb2+, Co2+, Ni2+, Fe2+, and Cu2+, with the direction and magnitude of the response varying by ion. A preliminary paper-based assay further confirmed that CTAB- and CHX-induced fluorescence changes remain detectable when poly(IN5CA) is immobilized on a solid support, though with a concentration dependence distinct from that observed in solution. This pattern of divergent, ion-specific responses across both transduction modes is consistent with a chemically interpretable fingerprint rather than selective behavior. Although drift correction, selectivity, reversibility, and validation in real matrices remain necessary, the results identify poly(IN5CA) as a promising low-cost material for sensor arrays, wastewater surveillance, disinfectant residue monitoring, and adaptive process control.

Authors

Institutions

Publication Details

Journal
ACS Polymers Au
Published
2026-10-22
DOI
https://doi.org/10.1021/acspolymersau.6c00193
Primary Topic
Conducting polymers and applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Poly(indole-5-carboxylic acid) Synthesized by Acid-Assisted Polymerization as an Innovative Material for Detecting Cationic Surfactants and Heavy-Metal Ions

Jiřina Hromádková, Libor Kobera, Zuzana Walterová, Martin Hrubý et al.
ACS Polymers Au
Conducting polymers and applications
article

Poly(indole-5-carboxylic acid) Synthesized by Acid-Assisted Polymerization as an Innovative Material for Detecting Cationic Surfactants and Heavy-Metal Ions

Jiřina Hromádková, Libor Kobera, Zuzana Walterová, Martin Hrubý, Elena Tomšík, Jiří Pánek, Václav Pokorný, Ivana Šeděnková, Nikol Janić
article en

Abstract

Abstract Poly(indole-5-carboxylic acid) [poly(IN5CA)] was prepared by acid-assisted oxidative polymerization of the indole-5-carboxylic acid monomer in concentrated formic acid, using ammonium peroxodisulfate as the oxidant, at three monomer-to-oxidant ratios, and evaluated as a proof-of-concept sensing platform. MALDI-TOF mass spectrometry showed a dominant peak consistent with a cyclic trimer, together with a minor series of higher-mass peaks spaced at single monomer-unit intervals, indicating that a small fraction of the material extends as linear oligomers. Raman and ATR-FTIR spectroscopy confirmed oxidized conjugated segments. At the highest oxidant loading (1:1), ATR-FTIR revealed strong carboxylate (COO–) bands indicative of an additional, oxidant-induced transformation of the carboxylic acid groups; the intermediate 2:1 ratio was therefore selected, as it yielded oxidized conjugated oligomers without this transformation. X-ray diffraction showed the material to be predominantly amorphous, with a minor crystalline component attributed to a residual sulfate-based salt derived from the oxidant. The selected formulation remained stable within its UV–vis spectral envelope over 21 days, while fluorescence intensity showed a modest, nonmonotonic variation over the same period. Poly(IN5CA), immobilized as a drop-cast film on glassy-carbon electrodes, showed a concentration-dependent potentiometric response to the cationic surfactants CTAB and CHX, attributed to neutralization of the film’s negative surface charge. The CTAB slope (−21.2 mV/decade) was markedly sub-Nernstian for a monovalent cation, whereas the CHX slope (−29.2 mV/decade) closely approached the theoretical value expected for an effectively divalent cation. A potentiometric response to the heavy metal ions tested was not reproducible under the present conditions. In solution, the free polymer showed a fluorometric response to both surfactants and to Pb2+, Co2+, Ni2+, Fe2+, and Cu2+, with the direction and magnitude of the response varying by ion. A preliminary paper-based assay further confirmed that CTAB- and CHX-induced fluorescence changes remain detectable when poly(IN5CA) is immobilized on a solid support, though with a concentration dependence distinct from that observed in solution. This pattern of divergent, ion-specific responses across both transduction modes is consistent with a chemically interpretable fingerprint rather than selective behavior. Although drift correction, selectivity, reversibility, and validation in real matrices remain necessary, the results identify poly(IN5CA) as a promising low-cost material for sensor arrays, wastewater surveillance, disinfectant residue monitoring, and adaptive process control.

ACS Polymers Au
Czech Academy of Sciences, Institute of Macromolecular Chemistry (CZ), University of Chemistry and Technology, Prague (CZ)
Openalex Percentile: Top 26%
Conducting polymers and applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon