Smartphone-Assisted Phenol–Sulfuric Acid Assay with ImageJ Analysis for Total Carbohydrate Quantification

The phenol–sulfuric acid (PSA) assay is widely recognized for its versatility and simplicity in the detection and quantification of carbohydrates. However, as well as the appropriate reagents, this method requires a UV–visible spectrophotometer, the cost of which may be prohibitive for some research groups. This study aims to revisit the PSA assay and investigate a novel smartphone-assisted method as a potential alternative to using a spectrophotometer. To the best of our knowledge this is the first time the PSA assay has been used in this way. A range of monosaccharides—glucose, fructose, galactose, xylose, arabinose, mannose, fucose, rhamnose, and galacturonic acid—were tested to establish calibration curves and evaluate the PSA assay’s quantitative parameters, utilizing both the traditional spectrophotometer-based method and the adapted smartphone-assisted assay, where ImageJ was used to estimate the change in “colour” of the samples. Calibration curves generated from the traditional method demonstrated excellent linearity, with adjusted coefficients of determination (Adj. R2) between 0.992 and 0.998; the slopes (m), intercepts (c) and the standard deviation of the residuals of these curves (sx/y) were used to estimate the limits of detection (LOD) and limits of quantification (LOQ) at 95% confidence. For the traditional PSA assay, the LOD values ranged from 5.5 to 12.3 ppm and the LOQ values from 16.8 to 37.5 ppm. Differences in the LOD/LOQ between different monosaccharides were attributed to variations in chemical reactivity, molecular structure, and chromophore absorbance at 490 nm. The smartphone-assisted PSA assay with ImageJ also demonstrated excellent linearity, with adjusted coefficients of determination (Adj. R2) between 0.991 and 0.997. The LOD values ranged from 7.9 to 13.1 ppm and the LOQ values from 24.1 to 39.9 ppm, providing an alternative for use in resource-limited environments. To demonstrate the potential usefulness of this assay, two case studies were undertaken: (i) to estimate the total carbohydrate content of pectin-like polymers from okra and potato, using both the traditional and smartphone-assisted PSA assay with ImageJ; and (ii) to generate a chromatogram in the preparative size exclusion chromatography (SEC) of a commercial citrus pectin sample. In the first case study, the total carbohydrate contents across all samples were similar using both methods and in the second case study this allowed the analysis of 32 samples (in triplicate) in one image. Future work should focus on fully optimising both image capture and the analysis steps of the new protocol and extending the method’s applicability to complex biological and environmental matrices. Overall, this study offers an alternative to the traditional PSA assay, reinforcing its role as a fundamental tool in modern carbohydrate quantification.

Authors

Institutions

Publication Details

Journal
Molecules
Published
2026-10-22
DOI
https://doi.org/10.3390/molecules31213794
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Smartphone-Assisted Phenol–Sulfuric Acid Assay with ImageJ Analysis for Total Carbohydrate Quantification

Zaiba Iqbal, Gordon A. Morris
Molecules
Biosensors and Analytical Detection
article

Smartphone-Assisted Phenol–Sulfuric Acid Assay with ImageJ Analysis for Total Carbohydrate Quantification

Zaiba Iqbal, Gordon A. Morris
article en

Abstract

The phenol–sulfuric acid (PSA) assay is widely recognized for its versatility and simplicity in the detection and quantification of carbohydrates. However, as well as the appropriate reagents, this method requires a UV–visible spectrophotometer, the cost of which may be prohibitive for some research groups. This study aims to revisit the PSA assay and investigate a novel smartphone-assisted method as a potential alternative to using a spectrophotometer. To the best of our knowledge this is the first time the PSA assay has been used in this way. A range of monosaccharides—glucose, fructose, galactose, xylose, arabinose, mannose, fucose, rhamnose, and galacturonic acid—were tested to establish calibration curves and evaluate the PSA assay’s quantitative parameters, utilizing both the traditional spectrophotometer-based method and the adapted smartphone-assisted assay, where ImageJ was used to estimate the change in “colour” of the samples. Calibration curves generated from the traditional method demonstrated excellent linearity, with adjusted coefficients of determination (Adj. R2) between 0.992 and 0.998; the slopes (m), intercepts (c) and the standard deviation of the residuals of these curves (sx/y) were used to estimate the limits of detection (LOD) and limits of quantification (LOQ) at 95% confidence. For the traditional PSA assay, the LOD values ranged from 5.5 to 12.3 ppm and the LOQ values from 16.8 to 37.5 ppm. Differences in the LOD/LOQ between different monosaccharides were attributed to variations in chemical reactivity, molecular structure, and chromophore absorbance at 490 nm. The smartphone-assisted PSA assay with ImageJ also demonstrated excellent linearity, with adjusted coefficients of determination (Adj. R2) between 0.991 and 0.997. The LOD values ranged from 7.9 to 13.1 ppm and the LOQ values from 24.1 to 39.9 ppm, providing an alternative for use in resource-limited environments. To demonstrate the potential usefulness of this assay, two case studies were undertaken: (i) to estimate the total carbohydrate content of pectin-like polymers from okra and potato, using both the traditional and smartphone-assisted PSA assay with ImageJ; and (ii) to generate a chromatogram in the preparative size exclusion chromatography (SEC) of a commercial citrus pectin sample. In the first case study, the total carbohydrate contents across all samples were similar using both methods and in the second case study this allowed the analysis of 32 samples (in triplicate) in one image. Future work should focus on fully optimising both image capture and the analysis steps of the new protocol and extending the method’s applicability to complex biological and environmental matrices. Overall, this study offers an alternative to the traditional PSA assay, reinforcing its role as a fundamental tool in modern carbohydrate quantification.

MoleculesVol. 31(21)
University of Huddersfield (GB)
Openalex Percentile: Top 24%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon