Time-aware frame-aligned diffusion-inspired model for late dynamic PET frame prediction from early [ 11 C] raclopride
Objective . To reduce the burden of dynamic positron emission tomography (PET) acquisition while preserving quantitative analysis, we propose a time-aware frame-aligned diffusion-inspired residual denoising framework for predicting late dynamic PET frames from a short early acquisition window (10 min in this study) of [ 11 C] raclopride. Approach . Irregular native dynamic frames were converted to a uniform 1 min indexing grid using overlap-weighted rebinning. The first 10 min were used as the early input and to derive the spatial and intensity preprocessing parameters. For each requested late time, a shared time-aware 3D U-Net predicted an anchor-relative residual with respect to the last available early frame. A training-only denoising diffusion probabilistic model (DDPM)-inspired Gaussian perturbation and noise-prediction branch shared the prediction backbone and regularized residual learning, while temporal-consistency loss constrained predicted frame-to-frame changes. All learning-based methods used identical subject-wise five-fold cross-validation within the development cohort, followed by evaluation on a fixed internal test set; the external cohort was held out from model selection. Main results . The proposed approach achieved higher Peak signal-to-noise ratio and structural similarity index measure and lower mean absolute error than the comparison methods, while providing closer agreement with reference TACs and simplified reference tissue model-derived parameter estimates across the limbic, associative, and sensorimotor striata. Significance . The proposed framework provides deterministic time-resolved late-frame estimates from early dynamic PET while using a DDPM-inspired noise-prediction objective only as an auxiliary training regularizer rather than as an iterative diffusion inference process. This design may support shortened dynamic PET protocols while retaining TAC and kinetic-parameter fidelity.
Authors
- Yu Jin Seol (ORCID: https://orcid.org/0000-0002-4930-3913)
- Euitae Kim (ORCID: https://orcid.org/0000-0003-0914-2331)
- Jae Sung Lee (ORCID: https://orcid.org/0000-0001-7623-053X)
- Seung Kwan Kang (ORCID: https://orcid.org/0009-0000-3292-8370)
Institutions
- Seoul National University (KR)
- Daegu Gyeongbuk Institute of Science and Technology (KR)
- Seoul National University Bundang Hospital (KR)
Publication Details
- Journal
- Physics in Medicine and Biology
- Published
- 2026-11-18
- DOI
- https://doi.org/10.1088/1361-6560/aeb795
- Primary Topic
- Medical Imaging Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Korea Medical Device Development Fund
- National Research Foundation