Impact of different post-polymerization protocols on fracture load and two-body wear of 3D-printed fixed dental prostheses

Abstract Objectives To evaluate five post-polymerization protocols (385, 400 and 460 nm LEDs; one- and two-capacitor flashlights) and aging on fracture load (FL) and two-body wear (TBW) of three 3D-printed resins for fixed dental prostheses (FDPs). Materials and methods 360 single-unit FDPs for mandibular molars were DLP-printed from two permanent resins (Varseo Smile CrownPlus [VAR], Crowntec [CRO]) and one temporary resin (Freeprint temp [FRE]). Half was artificially aged (480,000 mastication cycles, thermocycling 5/55°C). FL was measured in a universal testing machine, TBW by laser scanning. Data were analysed with three-way ANOVA, Kruskal–Wallis and post-hoc tests (α = 0.05). Results The protocol ( p < 0.001) and the material ( p < 0.001) significantly affected FL, whereas aging showed no significant main effect ( p = 0.100); the three-way interaction was significant ( p = 0.009). Initially, 460 nm yielded the highest FL for VAR (1505 ± 251 N) and FRE (1910 ± 237 N), the two-capacitor flashlight for CRO (1783 ± 333 N). Aging increased FL significantly in two and decreased it in three of 15 combinations. TBW (− 0.16 to − 0.35 mm) did not differ between protocols or materials. Conclusions The protocol effect on FL depended on the material and the aging level. Aging had no overall effect but increased FL in two combinations, possibly through continued polymerization. Protocol selection should consider the material. Clinical relevance Mean fracture loads exceeded reported maximum molar bite forces, although individual specimens failed below that range. Two-capacitor flashlight post-curing gave the most consistent performance for the materials tested.

Authors

Institutions

Publication Details

Journal
Clinical Oral Investigations
Published
2026-10-22
DOI
https://doi.org/10.1007/s00784-026-07232-9
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of different post-polymerization protocols on fracture load and two-body wear of 3D-printed fixed dental prostheses

John Meinen, Moritz Hoffmann, Marcel Reymus, Bogna Stawarczyk et al.
Clinical Oral Investigations
Dental materials and restorations
article

Impact of different post-polymerization protocols on fracture load and two-body wear of 3D-printed fixed dental prostheses

John Meinen, Moritz Hoffmann, Marcel Reymus, Bogna Stawarczyk, Felicitas Mayinger, Sophie Gekle, Ursula Kreitmair
article en

Abstract

Abstract Objectives To evaluate five post-polymerization protocols (385, 400 and 460 nm LEDs; one- and two-capacitor flashlights) and aging on fracture load (FL) and two-body wear (TBW) of three 3D-printed resins for fixed dental prostheses (FDPs). Materials and methods 360 single-unit FDPs for mandibular molars were DLP-printed from two permanent resins (Varseo Smile CrownPlus [VAR], Crowntec [CRO]) and one temporary resin (Freeprint temp [FRE]). Half was artificially aged (480,000 mastication cycles, thermocycling 5/55°C). FL was measured in a universal testing machine, TBW by laser scanning. Data were analysed with three-way ANOVA, Kruskal–Wallis and post-hoc tests (α = 0.05). Results The protocol ( p < 0.001) and the material ( p < 0.001) significantly affected FL, whereas aging showed no significant main effect ( p = 0.100); the three-way interaction was significant ( p = 0.009). Initially, 460 nm yielded the highest FL for VAR (1505 ± 251 N) and FRE (1910 ± 237 N), the two-capacitor flashlight for CRO (1783 ± 333 N). Aging increased FL significantly in two and decreased it in three of 15 combinations. TBW (− 0.16 to − 0.35 mm) did not differ between protocols or materials. Conclusions The protocol effect on FL depended on the material and the aging level. Aging had no overall effect but increased FL in two combinations, possibly through continued polymerization. Protocol selection should consider the material. Clinical relevance Mean fracture loads exceeded reported maximum molar bite forces, although individual specimens failed below that range. Two-capacitor flashlight post-curing gave the most consistent performance for the materials tested.

Clinical Oral InvestigationsVol. 30(11)
University of Basel (CH), LMU Klinikum (DE), Universitäres Zentrum für Zahnmedizin Basel (CH), Ludwig-Maximilians-Universität München (DE)
Good health and well-being
Openalex Percentile: Top 10%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon