‘One shunt fits all?’: a comparative laboratory study of antibiotic-impregnated shunt catheters with retrospective clinical correlation

Abstract Introduction Several antibiotic-impregnated shunt catheters are commercially available, but direct comparative data on their biochemical and physical characteristics remain limited. Previous observations from our single-centre neurosurgical unit suggested that nominally similar catheter types may be associated with different rates of otherwise unexplained abdominal pain. We therefore conducted a prospective comparative study to investigate potential biochemical and physical differences between commercially available antibiotic-impregnated shunt catheters. Methods Ares ® , Bactiseal ® and XABO ® catheters were compared for antibiotic content, rifampicin degradation products, elution characteristics and antimicrobial activity. Antibiotic elution was assessed during continuous saline perfusion at 20 mL/h and 37 °C over 8 weeks, while antimicrobial activity against Staphylococcus epidermidis was evaluated over 60 days. Catheter dimensions, elastic modulus and surface morphology were assessed using three-dimensional computed tomography, nanoindentation and scanning electron microscopy, respectively. An exploratory retrospective quality-improvement dataset from our single-centre unit was additionally analysed to compare the frequency of otherwise unexplained abdominal pain between catheter types. Results The three catheter systems showed product-specific differences in antibiotic content, rifampicin degradation profiles, elution characteristics, antimicrobial activity, dimensions, mechanical properties and surface morphology. XABO ® most closely matched the declared antibiotic concentrations and retained the greatest proportion of intact rifampicin, while Ares ® demonstrated the highest sustained clindamycin elution. All three catheters retained measurable activity against Staphylococcus epidermidis for 60 days, with XABO ® showing the largest numerical inhibition zones throughout. In the 395-patient retrospective clinical analysis, otherwise unexplained abdominal pain was recorded in 90/182 patients with Ares ® catheters (49.5%) compared with 12/108 patients with Bactiseal ® catheters (11.1%). After adjustment for age, sex, primary diagnosis, modified Rankin Scale score and activity level, Ares ® remained associated with greater odds of abdominal pain than Bactiseal ® (adjusted OR 6.89, 95% CI 2.58–18.43; p < 0.001). Conclusion Commercially available antibiotic-impregnated shunt catheters showed product-specific biochemical and physical variation, while catheter type was associated with different rates of otherwise unexplained abdominal pain in a retrospective single-centre analysis. These findings are hypothesis-generating and do not establish causality or clinical superiority. Prospective multicentre studies are required to determine whether catheter-specific properties translate into clinically meaningful differences and should influence individualised shunt selection.

Authors

Institutions

Publication Details

Journal
Acta Neurochirurgica
Published
2026-11-06
DOI
https://doi.org/10.1007/s00701-026-07079-9
Primary Topic
Cerebrospinal fluid and hydrocephalus
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

‘One shunt fits all?’: a comparative laboratory study of antibiotic-impregnated shunt catheters with retrospective clinical correlation

Mehran Moazen, Gillian Pace, Kanza Tariq, Anastasiia Maliuk et al.
Acta Neurochirurgica
Cerebrospinal fluid and hydrocephalus
article

‘One shunt fits all?’: a comparative laboratory study of antibiotic-impregnated shunt catheters with retrospective clinical correlation

Mehran Moazen, Gillian Pace, Kanza Tariq, Anastasiia Maliuk, Linda D’Antona, Oliver Harper, Lewis Thorne, Simon Thompson, Celine Krista Vicedo, Jesvin Sunny, Laurence Watkins, Ahmed K. Toma
article en

Abstract

Abstract Introduction Several antibiotic-impregnated shunt catheters are commercially available, but direct comparative data on their biochemical and physical characteristics remain limited. Previous observations from our single-centre neurosurgical unit suggested that nominally similar catheter types may be associated with different rates of otherwise unexplained abdominal pain. We therefore conducted a prospective comparative study to investigate potential biochemical and physical differences between commercially available antibiotic-impregnated shunt catheters. Methods Ares ® , Bactiseal ® and XABO ® catheters were compared for antibiotic content, rifampicin degradation products, elution characteristics and antimicrobial activity. Antibiotic elution was assessed during continuous saline perfusion at 20 mL/h and 37 °C over 8 weeks, while antimicrobial activity against Staphylococcus epidermidis was evaluated over 60 days. Catheter dimensions, elastic modulus and surface morphology were assessed using three-dimensional computed tomography, nanoindentation and scanning electron microscopy, respectively. An exploratory retrospective quality-improvement dataset from our single-centre unit was additionally analysed to compare the frequency of otherwise unexplained abdominal pain between catheter types. Results The three catheter systems showed product-specific differences in antibiotic content, rifampicin degradation profiles, elution characteristics, antimicrobial activity, dimensions, mechanical properties and surface morphology. XABO ® most closely matched the declared antibiotic concentrations and retained the greatest proportion of intact rifampicin, while Ares ® demonstrated the highest sustained clindamycin elution. All three catheters retained measurable activity against Staphylococcus epidermidis for 60 days, with XABO ® showing the largest numerical inhibition zones throughout. In the 395-patient retrospective clinical analysis, otherwise unexplained abdominal pain was recorded in 90/182 patients with Ares ® catheters (49.5%) compared with 12/108 patients with Bactiseal ® catheters (11.1%). After adjustment for age, sex, primary diagnosis, modified Rankin Scale score and activity level, Ares ® remained associated with greater odds of abdominal pain than Bactiseal ® (adjusted OR 6.89, 95% CI 2.58–18.43; p < 0.001). Conclusion Commercially available antibiotic-impregnated shunt catheters showed product-specific biochemical and physical variation, while catheter type was associated with different rates of otherwise unexplained abdominal pain in a retrospective single-centre analysis. These findings are hypothesis-generating and do not establish causality or clinical superiority. Prospective multicentre studies are required to determine whether catheter-specific properties translate into clinically meaningful differences and should influence individualised shunt selection.

Acta Neurochirurgica
National Hospital for Neurology and Neurosurgery (GB), UCL Queen Square Institute of Neurology (GB), University College London (GB)
National Brain Appeal
Good health and well-being
Openalex Percentile: Top 21%
Cerebrospinal fluid and hydrocephalus
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon