Ofloxacin removal, electrochemical performance, and antibiotic resistance gene responses in a FeO/C–Shewanella oneidensis MR-1 enhanced constructed wetland–microbial fuel cell with different cathodes

Ofloxacin (OFL) contamination can promote antibiotic resistance gene (ARG) enrichment, yet it remains unclear whether cathode configuration in constructed wetland–microbial fuel cells (CW-MFCs) can simultaneously affect OFL removal, electrochemical performance, and ARG-related microbial responses. To address this question, a CW-MFC incorporating a FeO/C– Shewanella oneidensis MR-1 enhanced bioanode was operated with three cathode materials: granular activated carbon (GAC), graphite plate (GP), and carbon felt (CF). Their effects on OFL removal, conventional pollutant removal, and electrochemical performance were evaluated, together with microbial community responses and the relative abundances of mexB and aac(6′)-Ib-cr under different OFL loads. During 45 d of cathode comparison at 1000 μg/L OFL, the GAC-based system achieved the highest time-averaged OFL removal efficiency (89.2%) and the highest average voltage output (approximately 364.5 mV), whereas the GP configuration exhibited a slightly higher peak power density during polarization testing. Increasing OFL loading was accompanied by marked microbial community restructuring and enrichment of both target ARGs. However, the S. oneidensis MR-1-augmented CW-MFC consistently showed lower mexB and aac (6′)-Ib-cr abundances than the conventional wetland and the non-inoculated FeO/C system. These findings indicate that cathode configuration was associated with differences in treatment and electrochemical performance, while FeO/C– S. oneidensis MR-1 bioaugmentation was associated with greater OFL stress tolerance and lower relative abundances of the two target ARGs.

Authors

Institutions

Publication Details

Journal
Journal of Water Process Engineering
Published
2026-10-19
DOI
https://doi.org/10.1016/j.jwpe.2026.111109
Primary Topic
Microbial Fuel Cells and Bioremediation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ofloxacin removal, electrochemical performance, and antibiotic resistance gene responses in a FeO/C–Shewanella oneidensis MR-1 enhanced constructed wetland–microbial fuel cell with different cathodes

Wanxin Cheng, Weiyuan Cao, Shen Tang, Yanhong Li et al.
Journal of Water Process Engineering
Microbial Fuel Cells and Bioremediation
article

Ofloxacin removal, electrochemical performance, and antibiotic resistance gene responses in a FeO/C–Shewanella oneidensis MR-1 enhanced constructed wetland–microbial fuel cell with different cathodes

Wanxin Cheng, Weiyuan Cao, Shen Tang, Yanhong Li, Dunqiu Wang, Zikang Zhao, Jie Zhang, Ruixue Xia
article en

Abstract

Ofloxacin (OFL) contamination can promote antibiotic resistance gene (ARG) enrichment, yet it remains unclear whether cathode configuration in constructed wetland–microbial fuel cells (CW-MFCs) can simultaneously affect OFL removal, electrochemical performance, and ARG-related microbial responses. To address this question, a CW-MFC incorporating a FeO/C– Shewanella oneidensis MR-1 enhanced bioanode was operated with three cathode materials: granular activated carbon (GAC), graphite plate (GP), and carbon felt (CF). Their effects on OFL removal, conventional pollutant removal, and electrochemical performance were evaluated, together with microbial community responses and the relative abundances of mexB and aac(6′)-Ib-cr under different OFL loads. During 45 d of cathode comparison at 1000 μg/L OFL, the GAC-based system achieved the highest time-averaged OFL removal efficiency (89.2%) and the highest average voltage output (approximately 364.5 mV), whereas the GP configuration exhibited a slightly higher peak power density during polarization testing. Increasing OFL loading was accompanied by marked microbial community restructuring and enrichment of both target ARGs. However, the S. oneidensis MR-1-augmented CW-MFC consistently showed lower mexB and aac (6′)-Ib-cr abundances than the conventional wetland and the non-inoculated FeO/C system. These findings indicate that cathode configuration was associated with differences in treatment and electrochemical performance, while FeO/C– S. oneidensis MR-1 bioaugmentation was associated with greater OFL stress tolerance and lower relative abundances of the two target ARGs.

Journal of Water Process EngineeringVol. 93
Guilin University of Technology (CN), Guangxi Key Laboratory of Environmental Pollution Control Theory and Technology (CN)
Openalex Percentile: Top 21%
Microbial Fuel Cells and Bioremediation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.