Variable-Magnification synthetic aperture Digital holographic microscopy integrated with dual electrically tunable lenses and oblique illumination

Digital holographic microscopy (DHM) incorporating electrically tunable lenses (ETLs) enables non-mechanical continuous zoom, yet its performance is fundamentally constrained by two coupled mechanisms—NA restriction induced by beam truncation and curvature-dependent dynamic aberrations—which collectively induce magnification-dependent resolution loss and image degradation. This study presents a variable-magnification oblique-illumination synthetic-aperture DHM (VM-OI-SA-DHM) that integrates a dual-ETL zoom imaging module with a multi-directional illumination module based on a spatial light modulator and a Fresnel biprism. Synchronized dual-ETL dynamic zooming enables continuous magnification from 9.3 × to 44.7 × under a fixed object–image conjugate plane, while multi-angle sub-aperture spectrum stitching compensates for the resulting NA loss and aberrations, recovering isotropic lateral resolution consistently superior to conventional ETL-based DHM across the zoom range. Quantitative evaluations demonstrate a stable 0.87 μm lateral resolution from 13.8 × to 44.7×, a 1.78-fold improvement over variable-magnification normal-incidence DHM. The synthetic equivalent NA increases by 75% (from 0.20 to 0.35 at 10.3 × ) and by 57% (from 0.28 to 0.44 at 22.1 × and 38.0 × ), accompanied by an 8.21-fold reduction in background phase noise and a structural distinguishability index of 0.9786. Validation against white-light interferometry yields a phase reconstruction relative error of 4.39%. Biological imaging of skeletal muscle and ascaris sections confirms high-fidelity phase reconstruction. By compensating for these ETL-induced limitations, this work establishes a robust framework for cross-scale quantitative phase imaging and lays the groundwork for future magnification-scalable resolution enhancement.

Authors

Institutions

Publication Details

Journal
Optics & Laser Technology
Published
2026-10-19
DOI
https://doi.org/10.1016/j.optlastec.2026.116686
Primary Topic
Digital Holography and Microscopy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Variable-Magnification synthetic aperture Digital holographic microscopy integrated with dual electrically tunable lenses and oblique illumination

Benyong Chen, Liping Yan, Jiayi Chen, Liu Huang
Optics & Laser Technology
Digital Holography and Microscopy
article

Variable-Magnification synthetic aperture Digital holographic microscopy integrated with dual electrically tunable lenses and oblique illumination

Benyong Chen, Liping Yan, Jiayi Chen, Liu Huang
article en

Abstract

Digital holographic microscopy (DHM) incorporating electrically tunable lenses (ETLs) enables non-mechanical continuous zoom, yet its performance is fundamentally constrained by two coupled mechanisms—NA restriction induced by beam truncation and curvature-dependent dynamic aberrations—which collectively induce magnification-dependent resolution loss and image degradation. This study presents a variable-magnification oblique-illumination synthetic-aperture DHM (VM-OI-SA-DHM) that integrates a dual-ETL zoom imaging module with a multi-directional illumination module based on a spatial light modulator and a Fresnel biprism. Synchronized dual-ETL dynamic zooming enables continuous magnification from 9.3 × to 44.7 × under a fixed object–image conjugate plane, while multi-angle sub-aperture spectrum stitching compensates for the resulting NA loss and aberrations, recovering isotropic lateral resolution consistently superior to conventional ETL-based DHM across the zoom range. Quantitative evaluations demonstrate a stable 0.87 μm lateral resolution from 13.8 × to 44.7×, a 1.78-fold improvement over variable-magnification normal-incidence DHM. The synthetic equivalent NA increases by 75% (from 0.20 to 0.35 at 10.3 × ) and by 57% (from 0.28 to 0.44 at 22.1 × and 38.0 × ), accompanied by an 8.21-fold reduction in background phase noise and a structural distinguishability index of 0.9786. Validation against white-light interferometry yields a phase reconstruction relative error of 4.39%. Biological imaging of skeletal muscle and ascaris sections confirms high-fidelity phase reconstruction. By compensating for these ETL-induced limitations, this work establishes a robust framework for cross-scale quantitative phase imaging and lays the groundwork for future magnification-scalable resolution enhancement.

Optics & Laser TechnologyVol. 204
Zhejiang Sci-Tech University (CN), Zhejiang University of Science and Technology (CN)
Openalex Percentile: Top 19%
Digital Holography and Microscopy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.