Continuous Glucose Monitoring Is Not Ready for the Diagnosis of Prediabetes

With the growing availability of over-the-counter continuous glucose monitors, the question arises whether Continuous Glucose Monitoring (CGM) can be used to diagnose prediabetes. Traditionally, prediabetes is diagnosed using the oral Glucose Tolerance Test, a test with poor reproducibility. In a study from Singapore, there was large overlap between Ambulatory Glucose Profiles of people with prediabetes and normoglycemia. The optimal threshold of 5.64% Time above 140 mg/dL, the best discriminator, yielded 88% specificity and 48% sensitivity, indicating insufficient discriminatory value in many cases. In a study from Stanford, administration of a 75-gram oral glucose load while wearing CGM showed poor agreement with venous sampling between the category outcomes normoglycemia, prediabetes and diabetes. Future large cohort studies and AI may improve this situation. But for the moment, when a question of prediabetes arises, the most practical answer is to measure HbA1c, which allows for an elegant classification of normoglycemia, prediabetes and diabetes.

Authors

Institutions

Publication Details

Journal
Diabetes Technology & Therapeutics
Published
2026-10-19
DOI
https://doi.org/10.1177/15209156261485015
Citations
1
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
4.38
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Continuous Glucose Monitoring Is Not Ready for the Diagnosis of Prediabetes

J. Hans DeVries
1 citations
Diabetes Technology & Therapeutics
Diabetes Management and Research
4.38
article

Continuous Glucose Monitoring Is Not Ready for the Diagnosis of Prediabetes

J. Hans DeVries
article en
1 citations

Abstract

With the growing availability of over-the-counter continuous glucose monitors, the question arises whether Continuous Glucose Monitoring (CGM) can be used to diagnose prediabetes. Traditionally, prediabetes is diagnosed using the oral Glucose Tolerance Test, a test with poor reproducibility. In a study from Singapore, there was large overlap between Ambulatory Glucose Profiles of people with prediabetes and normoglycemia. The optimal threshold of 5.64% Time above 140 mg/dL, the best discriminator, yielded 88% specificity and 48% sensitivity, indicating insufficient discriminatory value in many cases. In a study from Stanford, administration of a 75-gram oral glucose load while wearing CGM showed poor agreement with venous sampling between the category outcomes normoglycemia, prediabetes and diabetes. Future large cohort studies and AI may improve this situation. But for the moment, when a question of prediabetes arises, the most practical answer is to measure HbA1c, which allows for an elegant classification of normoglycemia, prediabetes and diabetes.

Diabetes Technology & Therapeutics
Amsterdam University Medical Centers (NL), Profil Institute for Metabolic Research (DE)
Openalex Percentile: Top 4%
Diabetes Management and Research
4.38
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.