Multi-Observer Visceral Contention in an Unencumbered Room: Per-observer spatial partitioning versus global mean and min-max autonomic damping, with active pre-cancellation of the crosstalk

When an unencumbered room is the shared encoder for two standing observers, a scene-damping gain that reconciles an interocular step for one observer is an unrequested kinematic drive on the other. This paper extends the single-observer ordinary-differential-equation plant of the parent deposit (doi:10.5281/zenodo.23479465) to two observers integrated at 0.1 s from t = 0 to t = 720 s. Observer A, seed 42, half-saturation 3.5 ms, receives a unit conflict on (420 s, 660 s]. Observer B, seed 1042, half-saturation 4.5 ms, has conflict 0 throughout. Five regimes share those noise draws: open loop, global mean, global min-max, per-observer spatial partitioning with crosstalk 0.12, and active pre-cancellation of that crosstalk. Open-loop A reproduces the parent rows. Its simulated perfusion reaches 0 at 511.8 s. Open-loop B remains at perfusion 1. Under the mean, B's minimum is 0.446 at 664.6 s and A's minimum is 0.856 at 711.2 s. Under min-max, the step holds A at 2.340 ms and B at 6.120 ms; B's minimum is 0.379 at 665.2 s, and A's minimum is 0.692 at 720.0 s. Spatial partitioning keeps both minima at or above 0.70: 0.931 for A at 670.1 s, and 1.000 for B. During the step that regime holds A at 3.079 ms and 0.0585 Hz, and B at 2.054 ms and 0.0507 Hz. Active pre-cancellation also keeps both minima at or above 0.70 inside the window. A's minimum is 0.721 at 720.0 s, and B stays at 1.000. During the step, A matches the spatial hold and B stays at the open-loop baseline, with delivered gains 0.774 and 0. At 720 s, A is at 4.875 ms, HF = 0.497, and 0.0741 Hz. These quantities describe the plant and the five arbitration laws.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-10-19
DOI
https://doi.org/10.5281/zenodo.23480454
Primary Topic
Heart Rate Variability and Autonomic Control
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Multi-Observer Visceral Contention in an Unencumbered Room: Per-observer spatial partitioning versus global mean and min-max autonomic damping, with active pre-cancellation of the crosstalk

Denise Venerable, Gemini Google, Grok SpaceXAI
Zenodo (CERN European Organization for Nuclear Research)
Heart Rate Variability and Autonomic Control
preprint

Multi-Observer Visceral Contention in an Unencumbered Room: Per-observer spatial partitioning versus global mean and min-max autonomic damping, with active pre-cancellation of the crosstalk

Denise Venerable, Gemini Google, Grok SpaceXAI
preprint en

Abstract

When an unencumbered room is the shared encoder for two standing observers, a scene-damping gain that reconciles an interocular step for one observer is an unrequested kinematic drive on the other. This paper extends the single-observer ordinary-differential-equation plant of the parent deposit (doi:10.5281/zenodo.23479465) to two observers integrated at 0.1 s from t = 0 to t = 720 s. Observer A, seed 42, half-saturation 3.5 ms, receives a unit conflict on (420 s, 660 s]. Observer B, seed 1042, half-saturation 4.5 ms, has conflict 0 throughout. Five regimes share those noise draws: open loop, global mean, global min-max, per-observer spatial partitioning with crosstalk 0.12, and active pre-cancellation of that crosstalk. Open-loop A reproduces the parent rows. Its simulated perfusion reaches 0 at 511.8 s. Open-loop B remains at perfusion 1. Under the mean, B's minimum is 0.446 at 664.6 s and A's minimum is 0.856 at 711.2 s. Under min-max, the step holds A at 2.340 ms and B at 6.120 ms; B's minimum is 0.379 at 665.2 s, and A's minimum is 0.692 at 720.0 s. Spatial partitioning keeps both minima at or above 0.70: 0.931 for A at 670.1 s, and 1.000 for B. During the step that regime holds A at 3.079 ms and 0.0585 Hz, and B at 2.054 ms and 0.0507 Hz. Active pre-cancellation also keeps both minima at or above 0.70 inside the window. A's minimum is 0.721 at 720.0 s, and B stays at 1.000. During the step, A matches the spatial hold and B stays at the open-loop baseline, with delivered gains 0.774 and 0. At 720 s, A is at 4.875 ms, HF = 0.497, and 0.0741 Hz. These quantities describe the plant and the five arbitration laws.

Zenodo (CERN European Organization for Nuclear Research)
Heart Rate Variability and Autonomic Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.